12-29-2012, 12:41 AM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
upon replacement of both exchangers there was no...
upon replacement of both exchangers there was no signs of rust or sludge build up on the socondary, also no restrictions or considerable lint or debris found on the AC coil the rings from the clam...
-
12-19-2012, 11:04 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
this particular unit did not have any sludge what...
this particular unit did not have any sludge what so ever!
-
12-19-2012, 10:19 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
upon inspection this exchanger was very clean...
upon inspection this exchanger was very clean small buildup @ the bottom where the transfer box to the secondary bolts on.
-
12-19-2012, 10:17 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
we found 6 rings busted out, plus first post...
we found 6 rings busted out, plus first post explained that we switched the roll-outs and the unit kept tripping on the same spot not the switch.
-
12-15-2012, 07:07 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
it's not like i didn't test for it, that has been...
it's not like i didn't test for it, that has been my diagnosis from the begining but I frustrated because could not prove or document it!
-
12-15-2012, 07:06 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
it always did in the past same analizer model,...
it always did in the past same analizer model, has a screen for flue and conditioned air. selection for gas type etc...
-
12-14-2012, 06:51 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
the "saga" continues, received the secondary...
the "saga" continues, received the secondary yesterday, so we proceeded to change it today when I pulled it out I found 2 rings from the clam shell of the primary and proceeded to pull that out and...
-
12-11-2012, 08:11 AM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
Secondary HE will be replaced customer is...
Secondary HE will be replaced customer is debating about primary since it might not be under warranty.
-
12-11-2012, 08:09 AM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
plastic? you mean collector box? that was...
plastic? you mean collector box? that was inspected and look fine at the time. why would it be dry on top if that was leaking. I have also taken the blower and looked at the secondary (before the...
-
12-10-2012, 07:36 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
I forgot what the orinal problem was :) no I...
I forgot what the orinal problem was :) no I didn't, but I was confused about what he was talking about, it wouldn't do much for the puddle of water, either.
-
12-10-2012, 07:09 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
jump what out?
jump what out?
-
12-10-2012, 07:07 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
that's what I was leaning towards but wanted to...
that's what I was leaning towards but wanted to see if anybody had any thing similar that I could have of mis-interpreted. thank you!
-
12-08-2012, 07:56 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
follow up...........first of all thank you to all...
follow up...........first of all thank you to all for your feedback it has helped me a lot. so customer called today saying he found water on the floor near the furnace and water heater, the water...
-
12-08-2012, 07:45 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
yes i have, these dont have a restrictor but the...
yes i have, these dont have a restrictor but the do have a gasket that tends to fall apart and to center the inducer over the opening is kinda tricky but all that looks good. i was there today so...
-
12-08-2012, 11:38 AM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
I don't have my notes and i forgot what the O2...
I don't have my notes and i forgot what the O2 was but it ran almost 45 min it started with a 92% efficiency later on dropped to the 89%, i almost thought i had it figured out because it ran so long....
-
12-08-2012, 10:27 AM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
I don't know what you mean by hot side of the...
I don't know what you mean by hot side of the secondary?? but I've inspected the collector box, I guess they are prown to cracking and while it was off all the pipes of the secondary looked pretty...
-
12-08-2012, 10:21 AM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
sorry, forgot to mention that has been done the...
sorry, forgot to mention that has been done the flue readings where about 89% efficiency 122F & 6.2 CO
-
12-08-2012, 10:16 AM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
I thought about that but could not make any sense...
I thought about that but could not make any sense why it would start all of the sudden, but that will be next probably monday!
-
12-07-2012, 10:44 PM
Thread: roll-out tripping!
by frustraded tech- Replies
- 42
- Views
- 3,624
roll-out tripping!
Hi guys,
new guy on here, working on a HEIL Model # H9MPD075F12A2 that is tripping the rollout swith after watching the thing run and start many times it has become evident that there is no flame...
Results 1 to 19 of 19