  1. yes thanks it was helpful knowing stuff like ...

    yes thanks it was helpful knowing stuff like this happens .as mentioned before i am a competent mechanic .doing it for yrs , but this was a first experience with this . on a ...
  2. could have used him

    could have used him
  3. PS as of yet i haven't talked to him . will ...

    PS as of yet i haven't talked to him . will let you know what happens .
  4. it was a job he did it was his customer ....

    it was a job he did it was his customer . he put the hole in the coil when changing the furnace and and his son removed the coil to repair it ,which he did and put it back ...
  5. thanks for the input guys .i believe i did...

    thanks for the input guys .i believe i did everything properly for the most part .been doing this for yrs . but as mentioned before this is my first experience when this ...
  6. thanks

    thanks
  7. read some of the reply s you got . some ...

    read some of the reply s you got . some suggested it was shorted possible .my wiring was correct but when it happen it to went off like a shot gun and dumped the ...
  8. thanks for your in put dave

    thanks for your in put dave
  9. thanks for your reply.upon upon working on ...

    thanks for your reply.upon upon working on this unit i did have to reset the breaker so it was tripped before i got there . the plumber who changed the furnace that ...
  10. compress terminal blew out of the compressor .

    hello i was working on a 2004 train unit .the plumbing contractor had installed a new furnace and in doing so put a hole in the existing evap coil . long story short they...
  11. its a tough call what i found out is a...

    its a tough call what i found out is a lot of the name brand units are not made here . at least their residential lines like Rudd, i believe train, and others . what ...
  12. Replies
    0
    Views
    1,174

    i need some ideas . i have a potential job to...

    i need some ideas . i have a potential job to install a hvac system in a finished basement . the house already is two zoned central ac system comming from the attic with baseboard heat on the main...
  13. Replies
    1
    Views
    585

    hay every one i have an old ge ac condensing unit...

    hay every one i have an old ge ac condensing unit i am not sure of the btu size its in a residential split system. the model # is 211A030H1 i dont know if 030 represents 30000 btu ornot i want to...
  14. Replies
    0
    Views
    814

    i am trying to trouble shoot i pilot ingntion...

    i am trying to trouble shoot i pilot ingntion problem on a rheem rooftop unit . its only about 6 yrs old.it has the spark type ingnition .i went through a series of trouble shooting but i could use...
  15. Replies
    30
    Views
    10,225

    i guesse there trying to get more heat .

    i guesse there trying to get more heat .
  16. Thread: TEST ?

    by honest dave
    Replies
    3
    Views
    950

    why do caps fail

    ive seen capactors fail due to water laying ontop of them causing them to short across the terminals.
  17. Replies
    4
    Views
    2,122

    yes the system was running ok but the owner...

    yes the system was running ok but the owner wanted to know for sure if the charge was up to specs. i will have to wait for warmer weather. also i mentioned to the owner i wouldnt bother running the...
  18. Replies
    4
    Views
    2,122

    charging heatpump

  19. Replies
    4
    Views
    2,122

    i went to check out the charge on the unit for a...

    i went to check out the charge on the unit for a friend of mine. the unit seems to run ok but the charging graf only refers to cooling only mode. i could check the charge easy enough in summer time...