    Contractors lisence

    I've looked all over the place and I can not find a place or any information on how and/or where to take the the class/test to get my contractors lisence. I live in ocala Fl. Any info would be...
  2. Replies
    16
    Views
    940

    It sits in a square with four total condensers....

    It sits in a square with four total condensers. Condenser coil is clean. About 1.5 feet apart. It's a really bad set up. The units are about 6 years old. Coil is clean cause I cleaned them.
  3. Replies
    16
    Views
    940

    Comp is amping ok

    Comp is amping ok
  4. Replies
    16
    Views
    940

    52 is low side pipe temp. Yeah SC is high

    52 is low side pipe temp. Yeah SC is high
  5. Replies
    16
    Views
    940

    7.5 ton American standard

    Working on this unit customer says its not cooling like it should. I got 76 low side pressure 285 high side. Low side temp 52 high side 100. Got 100 degree entering dry bulb at condenser. I got a 14...
  6. Replies
    20
    Views
    1,125

    So is it normal for it to ice on the compressor...

    So is it normal for it to ice on the compressor side and ice half the head of the compressor?
  7. Replies
    20
    Views
    1,125

    I've never seen a CPR on a true case nor anywhere...

    I've never seen a CPR on a true case nor anywhere else. I've only been doing these small cases for little over a year. Been residential AC for over 15 years. I'm with a different company and they do...
  8. Replies
    20
    Views
    1,125

    First time on this brand. If it were a TRUE case...

    First time on this brand. If it were a TRUE case it would be fixed. I'm very familiar with them.
  9. Replies
    20
    Views
    1,125

    Just couldn't get suction line temp down past...

    Just couldn't get suction line temp down past about 45 to 50 degrees. I even opened the TXV but couldn't get pressure above 28
  10. Replies
    20
    Views
    1,125

    About 45 min fans never came on either in box

    About 45 min fans never came on either in box
  11. Replies
    20
    Views
    1,125

    It's a Howard/ McCray box

    It's a Howard/ McCray box
  12. Replies
    20
    Views
    1,125

    Box temp 65 no product in box, txv, 25 low side...

    Box temp 65 no product in box, txv, 25 low side 255 high side. SH was around 35. Didn't check SC but sight glass is full. It's 404a freon. That's about all I have. end of the day job you know
  13. Replies
    20
    Views
    1,125

    Three door reach in freezer

    Got this freezer in working on. I can't get the temp down. I noticed the crankcase pressure regulator was iceing on the comp side. This is a new freezer about a year old. I have never seen this on a...
  14. Replies
    33
    Views
    4,355

    Way to take this thread to the extreme guys lol....

    Way to take this thread to the extreme guys lol. Great post though I appreciate every reply
  15. Replies
    33
    Views
    4,355

    Thanks everyone. I swapped two terminals and it...

    Thanks everyone. I swapped two terminals and it was fine. It's been a long day no doubt summer has hit in FL. But is that the only way to tell if its wires correctly. There has to be a way to know...
  16. Replies
    33
    Views
    4,355

    3 phase ac compressor

    Just put a new comp in this unit roof top package. Wires everything up push contractor in and the comp comes on but not pumping. How do I know I have the wireing on the correct terminal? It's late...
  17. Replies
    7
    Views
    459

    Thanks mike ill look into that. Do you have to...

    Thanks mike ill look into that. Do you have to recover all the R12 or can you go in over top of it? Not that its that important . Cause this unit only holds 17 ounces.
  18. Replies
    7
    Views
    459

    Raetone reach in 47 cu ft freezer.

    Got this freezer the other day for a very fair price. Unfortunately it's R12. It had a leak it the cap tube. Easy fix. My question is.. Is there a drop in replacement for R12? I don't want to go...
  19. Replies
    19
    Views
    1,934

    YEP! see it all the time.

    YEP! see it all the time.
  20. Replies
    19
    Views
    1,934

    check voltage on start up. had 244volts didn't...

    check voltage on start up. had 244volts didn't drop any on start up. got 5kw heat in each pulling 20 amps per unit. but this jump is only on start up at the condensing unit. and only one is doing it....
  21. Replies
    20
    Views
    8,833

    what time is diner!

    what time is diner!
  22. Replies
    19
    Views
    1,934

    amp spike on carrier 5 ton heat pump

    so i installed 2 carrier 5 ton heat pump systems in a doctors office about a week ago. customer called today and said this is the first time the used to the heat and they tripped the main 200 amp...
  23. Replies
    10
    Views
    959

    it was under warranty. and swapping the motor...

    it was under warranty. and swapping the motor fixed the problem. it's all good now. thanks guys for the input.
  24. Replies
    10
    Views
    959

    it's an X13 motor

    it's an X13 motor
  25. Replies
    10
    Views
    959

    the motor has the low voltage triggers going...

    the motor has the low voltage triggers going directly to it. unhooked both fan and heat low voltage wires and fan still runs. nothing going to motor but high voltage and the low voltage common wire.
Results 1 to 25 of 102
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event