    Am I missing something? I'm still thinking bad...

    Am I missing something? I'm still thinking bad module.
  2. Replies
    3
    Views
    139

    It's on an air handler. I checked voltage on the...

    It's on an air handler. I checked voltage on the ground wire to a screw on the air handler cabinet. The ground wire is coming back out of the module. When it's unplugged I have 126 on both power...
  3. Replies
    3
    Views
    139

    Trane Variable Speed Problem

    Hey guys, I got a call late in the day Wednesday with a XL15i being froze up that I installed in 08. When I get there I find that the blower is not running. I don't have the Tec-Mate or Zebra tester...
  4. Replies
    0
    Views
    116

    Robinair Dial a Charge

    380881

    Make me an offer if anybody is interested and could use it.
  5. Replies
    1
    Views
    139

    Inficon Tek-Mate

    Practically brand new. I did put the batteries in it but that's about it. 380871

    $75 plus shipping
  6. Replies
    2
    Views
    101

    Got it...that is what I was looking for....Thanks

    Got it...that is what I was looking for....Thanks
  7. Replies
    2
    Views
    101

    BYC030H1L0AB info needed

    Could someone point me in the direction of where to look to find info on this unit...much appreciated
  8. Replies
    13
    Views
    886

    It pulled down to 400 before I stopped it when...

    It pulled down to 400 before I stopped it when isolated. I have changed the oil 3 times just on this unit. Hooking up inside might be the way to go. I'm going to bring home another vacuum pump...
  9. Replies
    13
    Views
    886

    Vacuum on a unit

    I have a church up the road from me that someone has stole about 2' of liquid line. The church people didn't realize that something was missing so they ran it all day the next Sunday. I volunteered...
  10. Replies
    53
    Views
    2,671

    Have the contractor come back out and remove the...

    Have the contractor come back out and remove the runs that go into the shop and patch them with sheet metal.
  11. Replies
    65
    Views
    8,313

    I don't see that the installer strapped t-stat...

    I don't see that the installer strapped t-stat wires to the gas line. Looks like the 3/8 vinyl tuning is strapped to it but the t-stat wires are on the opposite side. I think your install looks good...
  12. Replies
    6
    Views
    326

    .

    .
  13. Replies
    6
    Views
    326

    He may have straightend them out because of the...

    He may have straightend them out because of the increased air volume out of the register would whistle or you would hear alot of turbulance. Opening up the register fins would increase free area of...
  14. Replies
    5
    Views
    977

    Have the HVAC dude come and check it. It might...

    Have the HVAC dude come and check it. It might just be a defrost t-stat bad. Either way I would want him to check it before expensive repairs.
  15. Replies
    6
    Views
    693

    How long did you leave it before you switched to...

    How long did you leave it before you switched to EM heat? You will need to have your local HVAC contractor come look at it. Was the oil furnace running when both lines felt cold?
  16. Replies
    15
    Views
    1,339

    Where I'm located we do not install humidifiers...

    Where I'm located we do not install humidifiers in an attic. Most flow through humidifiers can be mounted on return or supply. We tap them into the hot water line. If you set your t-stat to...
  17. Replies
    15
    Views
    914

    If you have a heatpump, your compressor is...

    If you have a heatpump, your compressor is supposed to be working. When you turn up the t-stat it should bring on the indoor fan and the outdoor unit. The fan speed could possible be slower for heat...
  18. I do think you are missing something.......FREON...

    I do think you are missing something.......FREON

    What was the high side pressure reading?
  19. Replies
    49
    Views
    3,599

    Odds are there was a leak in system and when your...

    Odds are there was a leak in system and when your partner charged the system back up it opened the leak worse. If it leaked out, there is a leak there. How warm was it in the house?
  20. Replies
    7
    Views
    1,292

    I'm about 20 minutes off the Pilot Mtn. exit....

    I'm about 20 minutes off the Pilot Mtn. exit. Then back toward Stuart VA.
    The company I work for is located in King.
  21. Replies
    7
    Views
    1,292

    2 back at you

    2 back at you
  22. Replies
    7
    Views
    1,292

    I purchased the torch from United Refrigeration...

    I purchased the torch from United Refrigeration in W/S in March $178 plus tax and it sat in between the front seat in the van. I maybe used it to sweat in 2 condenser units and 1 airhandler and a lil...
  23. Replies
    7
    Views
    1,292

    I'm just north of Winston Salem.

    I'm just north of Winston Salem.
  24. Replies
    7
    Views
    1,292

    HVAC tools for sale

    I have a NRP Air/Acetylene torch. It has been used very little. It has the regulator, 12' of hose and quick release #A3 and A8 tips.

    Also have a Yellow Jacket Gas pressure test kit. It's the one...
  25. Replies
    12
    Views
    1,084

    Thanks guys for the quick reply. I created an...

    Thanks guys for the quick reply. I created an account and have 2 on order.
    Now I'm gonna need to figure out how to use them with my Testo Manometer..:D