  1. Thread: Please Help!

    by REP
    Replies
    2
    Views
    300

    I agree with everything Skippedover said.Get a...

    I agree with everything Skippedover said.Get a second opinion!
    68 degrees tells us nothing.What is the return tempature?
    What is the subcooling? What is the cfm of the air?
    How dirty is the inside...
  2. Replies
    29
    Views
    1,999

    Actually it is true. Horse power is a unit of...

    Actually it is true.
    Horse power is a unit of measure.It is determined by the size of the armature,the number of copper windings,the size of the copper wire in the windings,the configuration of the...
  3. Replies
    29
    Views
    1,999

    All motors used in the US have to conform exactly...

    All motors used in the US have to conform exactly to the NEC and the UL codes.A 1/4 hp is a 1/4 hp is a 1/4 hp.
    All electrical appliances in the US will accept a 10% varriance i.e.
    a 120v motor...
  4. Replies
    7
    Views
    534

    So your remote doesn't go any higher than 76.Very...

    So your remote doesn't go any higher than 76.Very strange.
    Also its been a long time since I seen one but do you not have any vane adjustment?
  5. Replies
    29
    Views
    1,999

    The simple answer is that you got the wrong...

    The simple answer is that you got the wrong motor.
    When you replace a motor you look for 1) voltage 2) horse power 3)rpm
    4)frame 5)_service factor_ 6)type of bearings 7) rotation
    8 you always...
  6. Thread: Will not Cool

    by REP
    Replies
    14
    Views
    925

    Talk about the ultimate parts changer!!!!! I've...

    Talk about the ultimate parts changer!!!!!
    I've worked on units 30+ years old still kicking just fine.
    Replacing at 10 years is sheer nonsense.
    Its worked for ten years ,,,find out what is wrong....
  7. Replies
    14
    Views
    1,668

    I saw a segment on the Travel channel with Burt...

    I saw a segment on the Travel channel with Burt Wolf I think.It was a southern plantation.That also had a staircase as you discribe.
    The differance is that they had found natural gas on the...
  8. Replies
    14
    Views
    1,668

    Wow this is differant.You wanna go to the ice box...

    Wow this is differant.You wanna go to the ice box and get me a cold one so I can think about it.
  9. I have no idea what Mexico calls elec service.Is...

    I have no idea what Mexico calls elec service.Is it 100v or 120v or 150v ,I have no idea.Is it 50 or 60 hz?
    Then it might be wise to walk around a bit and see what brands are in common use.There is...
  10. Replies
    11
    Views
    7,531

    Unit is made in China. USA distrabrution is...

    Unit is made in China.
    USA distrabrution is spotty at best making parts availibility a guessing game.Tech support is wrose than parts supply.
    Warranty will most likely be like pulling teeth.
    But...
  11. Replies
    8
    Views
    1,195

    Well lets see. Its 100 degrees outside,,its 80...

    Well lets see.
    Its 100 degrees outside,,its 80 degrees inside and tou have 60 degree supply.
    Could be a dozen things but I'll go out on a limb and say its an air delivery problem,or its a dirty...
  12. Change the oil and go back to work.

    Change the oil and go back to work.
  13. Replies
    8
    Views
    721

    You're going to need to replace that "Trane" very...

    You're going to need to replace that "Trane" very soon if you don't remove the restriction to air flow soon.
  14. Replies
    20
    Views
    1,371

    Here is something you may not know.In order for a...

    Here is something you may not know.In order for a local wholesale house tyo carry the Trane line,They must employ a factory trained field service rep.His job is to educate Trane dealer on the Trane...
  15. Replies
    14
    Views
    1,134

    Oh OK thanks now I know.I've only seen pictures...

    Oh OK thanks now I know.I've only seen pictures of those.
  16. Replies
    14
    Views
    1,134

    This is what? A ptac unit or a mini split?Is it...

    This is what? A ptac unit or a mini split?Is it r22 or r410?
    Did it ever work to your satisfaction or is this a new unit?
    275/65 sounds like r22 at a 80 something outdoor ambiant.If it were 100 it...
  17. Replies
    6
    Views
    521

    You have more problems then I can help you out...

    You have more problems then I can help you out with.
    I can tell you that 13 seer is the lowest seer rating that can be legally sold and I can tell you that r410 is the only gas allowed in new...
  18. Replies
    13
    Views
    1,387

    I once got a call in the morning of a furnace...

    I once got a call in the morning of a furnace that wouldn't shut off.It was an elderly lady and she said it was so hot that her cat had laid on the steps and wouldn't even move to go outside.
    I got...
  19. Used to be a way of judging the competition. Did...

    Used to be a way of judging the competition.
    Did they have the 260 or did they piddle with a Universial
  20. Replies
    3
    Views
    795

    To make any kind of judgement call on your...

    To make any kind of judgement call on your ductwork from 2000 miles away is impossible.We would need pictures all around.
    We can say some general things like if you have 18 year old ductboard...
  21. Replies
    6
    Views
    1,383

    First with a new house or an old house everyone...

    First with a new house or an old house everyone is guessing on what size your house needs if they don't do a manuel "J".
    So if you want to live with someone's guess fine,if you want to know then...
  22. Replies
    4
    Views
    731

    I've seen and worked on a lot of differant...

    I've seen and worked on a lot of differant furnaces but I have never seen a "thin boy".
    Would it be possible to take some pictures of it(the more the merrier) and post them here?
    Its a long shot...
  23. Replies
    6
    Views
    521

    When you leave half a system in there are just...

    When you leave half a system in there are just too many things that you don't know that could bite you in the behind.
    Your best bet and your cheapest way out is to have a basic no bells or whistles...
  24. Replies
    14
    Views
    3,944

    OK a couple of things. First I don't know what...

    OK a couple of things.
    First I don't know what your design temps are.If 100 is an unusual high then your unit might be sized correctly.
    Second is that if your tech didn't look at the underside of...
  25. Replies
    4
    Views
    1,452

    The SOV would tell you.

    The SOV would tell you.