Search:

Type: Posts; User: Eduardo7

Search: Search took 0.00 seconds.

  1. Replies
    69
    Views
    3,157

    http://fierychill.com/review-of-vacuum-for-service...

    http://fierychill.com/review-of-vacuum-for-service-engineers-thermal-engineering-5225
  2. http://i130.photobucket.com/albums/p276/srglima/To...

    http://i130.photobucket.com/albums/p276/srglima/Tools/2014-03-28212457.jpg

    http://i130.photobucket.com/albums/p276/srglima/Tools/2014-03-29%2004.23.22.jpg
    ...
  3. http://ep.yimg.com/ca/I/yhst-128669497614690_2272_...

    http://ep.yimg.com/ca/I/yhst-128669497614690_2272_205604

    http://www.frankstools.com/ktcditowrmog1.html
  4. link example: ...

    link

    example:

    .http://i1278.photobucket.com/albums/y514/Eduardo-7/BluVac_avatar_zpsbe4cf5bc.jpg (without the first dot)
    ...
  5. Replies
    35
    Views
    3,839

    You shoudn't leave the oil in the vacuum pump for...

    You shoudn't leave the oil in the vacuum pump for so long time.
  6. Replies
    12
    Views
    1,004

    itsiceman, First of all let me make clear that...

    itsiceman,

    First of all let me make clear that I’m not saying that the Ashcroft DG25 digital gauge is a substitute for the AK-900. No, it isn’t!

    A 0.01 psi resolution gauge may be a very good...
  7. Which ref? R22 or R410-A?

    Which ref? R22 or R410-A?
  8. Replies
    12
    Views
    1,004

    No. This Ashcroft gauge has a resolution 25 times...

    No. This Ashcroft gauge has a resolution 25 times better than the AK-900

    From the AK-900 data sheet:
    "Digital readings have ¼ psi resolution on low side, 1 psi resolution on high side"
    ...
  9. Replies
    12
    Views
    1,004

    Yes, they cost almost US$1000.00 This one cost...

    Yes, they cost almost US$1000.00

    This one cost US$258.64 and it has the same resolution (0.01 psi)

    http://www.amazon.com/ASHCROFT-DG2551N1NAM02L200-General-Digital-200PSI/dp/B00AM1ZRKA
    ...
  10. Replies
    12
    Views
    1,004

    I just would like to share this doc: What you...

    I just would like to share this doc:

    What you should know about digital test gauge accuracy… Terminal Point versus Best Fit Straight Line Accuracy....
  11. I have this one:...

    I have this one:
    http://dezndt9i6z9ef.cloudfront.net/catalog/product/cache/6/image/348x/9df78eab33525d08d6e5fb8d27136e95/8/3/83037-458r.jpg

    http://www.toolbarn.com/ridgid-83037.html
  12. Replies
    2
    Views
    533

    Digital Torque Wrench

    Hi,

    Is there a digital torque wrench like this one with 10 N.m minimum torque?
    This one has a torque from 17 N.m to 85 N.m

    http://www.netupload.org/files/1x0nzow943ifgzl2bogu.jpg
    ...
  13. Replies
    75
    Views
    6,853

    http://www.jbind.com/pdf/Deep_Vacuum.pdf ...

    http://www.jbind.com/pdf/Deep_Vacuum.pdf

    "There are many recommendations regarding evacuation levels, some of which state: “Evacuate the system to below 200 microns.” This should not be...
  14. Replies
    75
    Views
    6,853

    http://hvac-talk.com/vbb/showthread.php?1271041-Va...

    http://hvac-talk.com/vbb/showthread.php?1271041-Vacuum-rated-valve-core-remover-tool&p=15346851#post15346851
  15. Replies
    29
    Views
    3,915

    In this page...

    In this page there is a comment:
    "Our exchange policy here is simple: show us how many core removal tools you have, either by proof of purchase or by sending us the old, non-working plungers....
  16. Replies
    29
    Views
    3,915

    hearthman, thank you very much! I“ve seen the 48...

    hearthman, thank you very much! I“ve seen the 48 minutes video. The problem is the plunger, but it doesn“t matter to me because the CRT is being used to pull a vacuum in new mini splits only.
    ...
  17. Replies
    8
    Views
    923

    If the vacuum hose is connected to the Appion...

    If the vacuum hose is connected to the Appion 5/16" VCR all you need is a 3/8" male x 1/4" fem coupler.
  18. Replies
    29
    Views
    3,915

    I bought both (1/4" and 5/16") one year ago and...

    I bought both (1/4" and 5/16") one year ago and they don't grip the Schader. Is this the problem with the extractor that you've mentioned?

    Thanks,
    Eduardo
  19. Replies
    186
    Views
    32,497

    I use DV-291...

    I use DV-291
    http://jbind.com/products/product-search-detail.aspx?SKU=DV-291
  20. Replies
    12
    Views
    1,206

    I'm not sure, but look at this:...

    I'm not sure, but look at this:...
  21. Replies
    6
    Views
    917

    http://www.youtube.com/watch?feature=player_embedd...

    http://www.youtube.com/watch?feature=player_embedded&v=qdv77SyBgKE
  22. Replies
    43
    Views
    4,149

    http://www.trutechtools.com/BluVac-Digital-Micron-...

    http://www.trutechtools.com/BluVac-Digital-Micron-Gauge_p_1641.html
  23. Replies
    43
    Views
    4,149

    Hi joeyd, One BluVac is on its way down to...

    Hi joeyd,

    One BluVac is on its way down to Rio!

    Just one question: Has it been tested with Nylog?
    http://refrigtech.com/Product/Sealants/Nylog/nylog_blue.html

    Will the reading be steady or...
Results 1 to 23 of 23
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event