Search:

Type: Posts; User: sneuberg

Search: Search took 0.00 seconds.

  1. Replies
    6
    Views
    739

    Thanks for your replies. I feel a lot better

    Thanks for your replies. I feel a lot better
  2. Replies
    6
    Views
    739

    Low Ambient Control

    I had a new Rheem HVAC system installed last year and itís functioning very well. I wish I could just enjoy the comfort, but Iím concerned about the Low Ambient Control (LAC) I had my contractor...
  3. Replies
    3
    Views
    932

    Faith in AHRI

    After some hunting I fould the AHRI site. http://www.ahridirectory.org/ahridirectory/pages/ac/defaultSearch.aspx.

    I believe this is an excellent resource for consumers who are skeptical about all...
  4. Replies
    7
    Views
    650

    Perhaps I should reconsider

    The installation instructions for the proposed Rheem 14AJM030A01 do not say anything about a solenoid value so perhaps it's not required. I thought it made sense from an economic point of view. My...
  5. Replies
    7
    Views
    650

    Solenoid Value

    My current HVAC system, which is going to be replaced, has a solenoid value in the liquid line. My contractor is telling that these are not required and they don't install them. There must have...
  6. Replies
    3
    Views
    932

    Is This Evaporator Coil Right

    An HVAC contractor has proposed the following:

    Rheem model RGPE07NBRQR furnace
    Rheem model RAEL037JEC condenser. (That 37 is probably supposed to be 36)
    ADP coil model RE47636E210B2922AP
    ...
  7. Replies
    1
    Views
    446

    I just want a Good Installation

    Iím about to look for a contractor to replace my 15 year old HVAC system. Iíve heard that a proper installation is often more important than the system one selects. Assuming this is true Iíd like...
  8. Replies
    4
    Views
    543

    Replacing a system with Arthitis

    Iím not naÔve and I try to be honest with myself. I know the system needs replacement. Iím about to ask for quotes on a new system, but there are so many questions. This is not just a new furnace,...
  9. Replies
    4
    Views
    543

    Furnace with Arthitis

    Iím having a strange problem with my Carrier Weathermaker 8000 58WAV furnace. Itís about fifteen years old and getting cranky. It doesnít want to start in the morning. I turn my thermostat down...
  10. Replies
    36
    Views
    2,421

    Thanks for the information

    Iíd like to thank all you for your input. Unfortunately none of them make me feel very good. The gist seems to be that I wasted a lot of money for a quick fix just so I could stay cool. I wasnít...
  11. Replies
    36
    Views
    2,421

    While I don't know the exact figures, the...

    While I don't know the exact figures, the preexisting system had enough air flow and the pressures/temperatures were reasonable. The preexisting system had a SEER of at least 12. The indoor unit...
  12. Replies
    36
    Views
    2,421

    Sorry

    I didn't mean to break the rules of this helpful forum. I thought the price in this context would have been ok. Unfortunately I can't see how one can edit ones original post. Let me know how and...
  13. Replies
    36
    Views
    2,421

    Determining the cause of high head pressure

    First I’d like to state that this is not a DIY question. If a procedure is forthcoming in this thread, I’ll have it performed by a professional.

    Specifically I would like to know if there is a...
  14. The theory of charging an R22 system without a TXV

    It is my understanding that the correct way to charge an R22 system without a TXV is by getting the actual superheat to match the target superheat. It is also my understanding that the target...
Results 1 to 14 of 14
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine