  1. Replies
    27
    Views
    1,640

    next time take a pic. That would have been cool...

    next time take a pic. That would have been cool if all of us on the site could have seen that. Is this all warranty work ?
  2. Replies
    67
    Views
    3,379

    this is exactly why i am never shy when it comes...

    this is exactly why i am never shy when it comes to calling true's tech support.
  3. Replies
    10
    Views
    717

    it achieves -30f in no time. The box is in a...

    it achieves -30f in no time. The box is in a lab...everytime the door opens the warmest temp entering is 70f. They dont open the door too often either.
  4. Replies
    10
    Views
    717

    has strip curtains, 40 min. defrost...but...

    has strip curtains, 40 min. defrost...but terminates after 20.
  5. Replies
    10
    Views
    717

    -30f wi freezer moisture issue ?

    so im having an issue w a -30 f wi freezer...it looks like a winter wonderland after 2 weeks. Im schedules to go deal w this tomorrow. Im gonna change out the 3 wire on general principle but i've...
  6. Replies
    25
    Views
    2,874

    it almost seems like that blower housing was...

    it almost seems like that blower housing was defective and just caved in.
  7. Replies
    25
    Views
    2,874

    holy smokes....that gotta put a crazy grin on...

    holy smokes....that gotta put a crazy grin on your face ! I have never seen anything like that.
  8. Didt he say he replaced to compressor ?

    Didt he say he replaced to compressor ?
  9. the overload is doing its job....it sounds like...

    the overload is doing its job....it sounds like the compressor starts, runs but doesn't start and run correctly. It sounds like your starting components are wired incorrectly. Forget about the...
  10. Replies
    11
    Views
    951

    Moved to Tech to Tech forum. i dont understand!?...

    Moved to Tech to Tech forum.
    i dont understand!? I guess because im not a pro member i can't get there...I signed up for it so im just waiting. I'll revisit this when that happens.....
  11. Replies
    11
    Views
    1,231

    properly set your lp control would be a good idea...

    properly set your lp control would be a good idea too.
  12. Replies
    11
    Views
    1,231

    im gonna guess that the low back pressure...

    im gonna guess that the low back pressure condenser is a accumulator.
  13. Replies
    11
    Views
    951

    that is it dandyme. Thanks, ps I applied for my...

    that is it dandyme. Thanks, ps I applied for my pro membership, sorry for the inconvenience. Mind if i hit u up w any questions about these schematics ?
  14. Replies
    11
    Views
    951

    yeh i looked at that earlier but its not the...

    yeh i looked at that earlier but its not the same. Thankyou though. My unit has a k46/k36 relay. Those schematics are different. Im having a problem w this unit and im trying not to have to cut...
  15. hell yah that 3 week on call rotation is a deal...

    hell yah that 3 week on call rotation is a deal breaker. Way too tight of a crew !
  16. Replies
    11
    Views
    951

    need schematics...

    lennox m# gcs20h-261-50-3p...for whatever reason i cant find the schematics anywhere ! Link would be super cool !
  17. thankyou for all the replies, I have decided not...

    thankyou for all the replies, I have decided not to accept the interview.
  18. considering supermarket refrigeration job ! have questions !

    So Im considering taking a job w/ a shop that only does supermarket refrigeration. On call every 3 weeks, no travel, and the service manager mentioned 80 hr weeks.....what....80 hr weeks, thats 7...
  19. Replies
    34
    Views
    2,653

    well thanks for your input litemech, that will...

    well thanks for your input litemech, that will help out a whole lot. So maybe, thank you much kind sire !
    Millasa-Don't forget your rogane
    Stu-rogane, check,
    Millisa-and don't forget to use it...
  20. by the way ! I know i should have hit the...

    by the way ! I know i should have hit the breaker, so me don't give me a ration of **** yall. I never heard it ( compressor ) trying to start, i never saw the cond. fan motors trying to run, there...
  21. no crankcase, i checked that too.

    no crankcase, i checked that too.
  22. hoses were my conductor ?

    when if while pulling my vacuum, moisture, oil whatever was creating continuity through the hoses and the compressor got hot due to low voltage ?
  23. compressor gets hot while pulling vacuum.

    Today I took a call on a 208/230 true ( tac49 ) display case. I found it short cycling, found a leak, repaired it and as i was pulling a vacuum something weird happened. It got smokin hot. I...
  24. Replies
    34
    Views
    2,653

    a little late but i'll get in on this one.

    I just had something like what your talking about happen to me today. I was working on a tac-49, true display case and had to repair a leak. I found it short-cycling, i turned the unit off at the...
  25. Replies
    2
    Views
    779

    cool

    I could not find any information on jb's site. You think they would mention how important it is to add lube oil to the pump's pump motor ! But they need repair work too I guess. Anyways, thanks...