Search:

Type: Posts; User: lowtemp

Page 1 of 10 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: working alone

    by lowtemp
    Replies
    25
    Views
    1,652

    the legislation will really effect the 'one man...

    the legislation will really effect the 'one man operations' where they have no one to maintain contact with and their office is their cell phones.
  2. Thread: working alone

    by lowtemp
    Replies
    25
    Views
    1,652

    coolerguy. do you work alone ? i think this all...

    coolerguy. do you work alone ? i think this all boils down to economics. unless it becomes law customer are going to complain.
  3. Thread: working alone

    by lowtemp
    Replies
    25
    Views
    1,652

    fire watch is usually a customer specific...

    fire watch is usually a customer specific requirement(eg. proctor and gamble) and confined space entry is required by law to have 2 ppl minimum. servicing someone's 600v 5 ton rooftop unit is a 1 man...
  4. Thread: working alone

    by lowtemp
    Replies
    25
    Views
    1,652

    since it is not officially law yet all the hvac...

    since it is not officially law yet all the hvac contractors are not on board yet. we will hold off as long as possible. BTW the second person has to be someone trained. so i guess paying the 8 year...
  5. Thread: working alone

    by lowtemp
    Replies
    25
    Views
    1,652

    working alone

    in ontario canada the Ontario Health and safety act (OHSA) is proposing a new legislation as follows: if you are working on equipment that has an input voltage of greater than 300V you can not work...
  6. Replies
    33
    Views
    5,625

    i like 414b better than 409a. i find the system...

    i like 414b better than 409a. i find the system runs high pressures on 409a. i have had more compressor failures on 409a conversions than with 414b. i do however carry both in my truck.
  7. Replies
    24
    Views
    3,077

    yes wires are connected to board and connected to...

    yes wires are connected to board and connected to the right terminals. there is no exposed magnet on these units like the S series. this is an Indigo unit. i dont believe there is a megnet in the...
  8. Replies
    24
    Views
    3,077

    manitowoc indigo -full bin problem

    Just installed a new machine at a Lonestar. Setup the ice thickness and ran through 1 cycle. the unit finished its harvest and then indicated i had a 'full bin' and that my water curtain was open....
  9. Replies
    14
    Views
    8,381

    just as an update the unit was a 48NLT030.

    just as an update the unit was a 48NLT030.
  10. Thread: 4th System

    by lowtemp
    Replies
    7
    Views
    1,647

    where is the drip leg on the gas line? It looks...

    where is the drip leg on the gas line? It looks like it goes straight into furnace. Thats a code violation in my area.
  11. Thread: system 636

    by lowtemp
    Replies
    1
    Views
    460

    system 636

    how many of you have used this new flue gas venting system? The new regulation took effect on jan.1,2007 in ontario.
  12. Replies
    130
    Views
    11,130

    Actually all HVAC contractors are DIYers. I put...

    Actually all HVAC contractors are DIYers. I put heating systems in all the homes ive owned.LOL
  13. Replies
    15
    Views
    837

    Well, in society the 'majority' isnt always...

    Well, in society the 'majority' isnt always right. I'll just leave it at that. This is my final post on this thread. Closed. BTW john , i just looked at your credentials. Kinda vague IMO. I guess you...
  14. Replies
    15
    Views
    837

    Someone here ask me to apply for 'pro' membership...

    Someone here ask me to apply for 'pro' membership before he would answer my question. Well i would , if the membership link took me to a secured web page. But it doesnt. I never give out my personal...
  15. Replies
    7
    Views
    450

    Limewire

    Limewire
  16. Thread: lennox pulse

    by lowtemp
    Replies
    37
    Views
    4,828

    I remember one of our techs telling us about a...

    I remember one of our techs telling us about a Pulse furnace he had installed .Him and another guy had just spent 3 days installing a complete heating system including duct work.All this done in a 3...
  17. Replies
    8
    Views
    605

    The final ford Taurus rolled off the assembly...

    The final ford Taurus rolled off the assembly line today in Atlanta. It also put 2000 people out of work.Way to go Ford!My parents bought a brand new taurus in 1986.
  18. Replies
    49
    Views
    12,194

    Wow that is the apitimy of 'fly by nighter'. I...

    Wow that is the apitimy of 'fly by nighter'. I would be embarassed to have a truck like that. I imagine the owner doesn't give a sh*t.
  19. Replies
    13
    Views
    5,733

    if the air handler is that dirty i would hate to...

    if the air handler is that dirty i would hate to see what the rest of the house looks like!
  20. Replies
    13
    Views
    5,733

    the tube sheet on that coil is practically rusted...

    the tube sheet on that coil is practically rusted through. Tell the owner that coil is garbage.
  21. Thread: My House

    by lowtemp
    Replies
    40
    Views
    6,326

    you must live in a warm climate. Since you have...

    you must live in a warm climate. Since you have your condensing gas furnace in the garage. Is the garage heated?
  22. Replies
    1
    Views
    1,367

    i was on a job today that has a non-bladder type...

    i was on a job today that has a non-bladder type expansion tank. The PRV has been seeping (homeowner thought water was coming for his wall) The boiler pressure was below 20psi when i arrived.Water...
  23. Replies
    92
    Views
    5,484

    john it sounds like you have what they call a...

    john it sounds like you have what they call a 'monoport' system. Which means each radiator has a regulating orfice that allows so much steam to enter it. This systems are a real pain in the ass! Your...
  24. Replies
    194
    Views
    18,639

    If the lettering on your truck is done in water...

    If the lettering on your truck is done in water colours.
  25. Replies
    4
    Views
    715

    I just bought a house with aluminum wiring .It...

    I just bought a house with aluminum wiring .It was built in 1974. Im having the panel upgraded to breakers and having all outlets checked.Im having any questionable ones relpaced with CO/ALR rated...