  1. Replies
    4
    Views
    1,312

    haveing prblem with pressure switch after...

    haveing prblem with pressure switch after replacing spark ign board. unit will fire and rn about a min and then the presuure switch starts to act up and shuts the unit down and then relites till the...
  2. Thread: york h/p

    by conair
    Replies
    2
    Views
    826

    old york heat pump m#e1cp024q6a pressure was 40...

    old york heat pump m#e1cp024q6a
    pressure was 40 at compressor and 100 at 3/4 line to indoor coil. out door ambiant was 25 degrees.
    heat at reversing valve was going to outdoor coil and to indoor...
  3. Thread: a/c pressure

    by conair
    Replies
    8
    Views
    1,634

    what do you mean you have a perfect charge at 70...

    what do you mean you have a perfect charge at 70 190????
    what is subcooling? 10 to 15 degrees subcooling would be a good charge 70 190 whats that? you need to learn how to charge first before you...
  4. Replies
    8
    Views
    1,519

    whats the full model number and serial. you...

    whats the full model number and serial.
    you might as well tell the cust they need a new furnace
    you could be trying to fix this awile
    does the board have amber light on it so you can see if it...
  5. Replies
    21
    Views
    5,837

    many things to look at first were are gauges...

    many things to look at first were are gauges connected and what kind of metering device is insde and out side?
    does this system matched?
    post more info?
  6. Replies
    10
    Views
    7,511

    just woked with one of these took advice from...

    just woked with one of these took advice from bald lonnie
    if you replaced the old board because the resistors were burned you were right for doing that you should now have the amber light to see if...
  7. Replies
    16
    Views
    9,322

    have the contractor check the charge if there is...

    have the contractor check the charge
    if there is a overcharge the unit will sweat to much
    set the superheat to 15 and that may fix the problem.
    see this all the time with new installs.
  8. Replies
    61
    Views
    7,647

    if you haveent already plz post the charge info...

    if you haveent already plz post the charge info the tech took and if this is a piston coil or exp.valve.
    what was the pressures, super heat, subcool ,out door amb, indoor wb and dry bulb!
    beleive...