Heat Pump Leak
Today I found a small leak in the evap coil of a heat pump with my leak detector. I told the customer that he had to replace the coil, but this wasn't something he wanted to do at the moment. I gave...
-
02-07-2013, 07:16 PM
- Replies
- 6
- Views
- 350
To be honest your gonna have to check everything....
To be honest your gonna have to check everything. Check the strips, the board the charge; everything.
-
02-07-2013, 06:48 PM
Thread: Determining correct charge on cool days
by sabur2121- Replies
- 10
- Views
- 472
The only way to properly charge the system on a...
The only way to properly charge the system on a cool day is to raise the head pressure along with wet bulb, dry bulb, pressure and temperature checks. Of course this depends on TXV or Fixed Orifice....
-
02-06-2013, 05:22 PM
Thread: Charging R410a and R422D
by sabur2121- Replies
- 2
- Views
- 327
Charging R410a and R422D
Can anyone direct me to a website that shows the proper way to charge R410a, and have any of you guys converted over to the new R22? I'm hearing different ways to convert. One of the ways was to...
-
06-12-2012, 11:56 PM
Thread: r22 pressures
by sabur2121- Replies
- 6
- Views
- 453
More information dude! GIVE US P/T ECT
More information dude! GIVE US P/T ECT
-
06-12-2012, 04:15 AM
Thread: compressior shuts off high SH/ Low SC.
by sabur2121- Replies
- 12
- Views
- 703
Sir, In a case like this, the only thing to do...
Sir,
In a case like this, the only thing to do is recover the juice and dive in! I would check the drier first to see if there is a temp difference there, if so that could be your problem. Check... -
Duct Books
Manual J along with Manual D/ Fibrous Duct/Sheet Metal etc
-
05-23-2012, 11:22 PM
Thread: Static pressure testing
by sabur2121- Replies
- 73
- Views
- 7,156
Static Pressure!
I think static pressure is very important. I can understand why some guys use 0.10, but its not very good practice. If you add electric filters ect. then you static pressure will change. The best...
-
04-27-2012, 12:35 AM
Thread: TXV or no TXV???
by sabur2121- Replies
- 54
- Views
- 3,536
TXV
Why would you not put a TXV on it? Is it a heat pump?
-
04-17-2012, 09:13 PM
Thread: Some recent work.
by sabur2121- Replies
- 25
- Views
- 2,529
Nice Work
I like that installation. How long did it take to complete?
-
04-11-2012, 09:23 PM
- Replies
- 11
- Views
- 818
Thanks guys!
Thanks guys!
-
04-11-2012, 10:08 AM
- Replies
- 11
- Views
- 818
Wiring High Voltage on Heat Pumps and Strips
Can anyone explain to me the process of installing the heat pump high voltage? I understand that this is 240v with a breaker of 60amps (normally). I'm assuming that this is a 5kw, but if I were to...
-
04-06-2012, 11:12 PM
Thread: No superheat!
by sabur2121- Replies
- 58
- Views
- 2,893
From what your saying is kind of confusing,...
From what your saying is kind of confusing, according to the numbers. What I would do is check for a restriction in the liquid line drier by measuring the temp in front and the back side of the...
-
05-03-2010, 07:43 AM
- Replies
- 12
- Views
- 608
If you have a 2 1/2 ton unit, you should be...
If you have a 2 1/2 ton unit, you should be pushing around about 1000 cfm's. The golden rule is 350 to 450cfm's per ton. I don't know the sf of your home, but you need to make sure that your unit is...