Search:

Type: Posts; User: Snapperhead

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    16
    Views
    404

    Thats CHEATING ! So whats the ill effect ? ...

    Thats CHEATING !

    So whats the ill effect ? Smaller cubes ?
  2. Replies
    14
    Views
    693

    I come across my first TXV stuck wide open last...

    I come across my first TXV stuck wide open last week. Walk-in Freezer 2 yrs old. Got there , heard refrig pouring through coil like crazy , felt coil its warm , Txv warm , Dist tubes warm , im...
  3. Thread: 410

    by Snapperhead
    Replies
    41
    Views
    916

    I like the way 410 tastes and smells ....

    I like the way 410 tastes and smells ....
  4. Google , images , is your friend Key words...

    Google , images , is your friend

    Key words compressor , wiring diagram , tecumseh , copeland
  5. Replies
    9
    Views
    269

    I've had great luck just leaving HS210 on for...

    I've had great luck just leaving HS210 on for ever for cheap customers and never had a call back .... but since im selling this unit Id like to make it original

    the 1/3 kit never seems to work...
  6. yea and since the coil is located in freezer you...

    yea and since the coil is located in freezer you really cant use anything else but air sensing

    A30-261 Ranco maybe .....
  7. Replies
    9
    Views
    269

    AEA4440YXA hard start

    So I have a used 2 door True box I wanna sell.

    Got from an auction , so i have no idea of history

    Coil half clogged ofcourse.

    Has the little slip on relay with start cap separate , and one...
  8. Replies
    10
    Views
    200

    why not just throw on a 12-701

    why not just throw on a 12-701
  9. yes , fans stay on , solenoid goes off ...

    yes , fans stay on , solenoid goes off

    someones been in there didnt know what he was doing ....

    have fun straightening that out

    BUT

    make sure that was the thermostat you turned up , and...
  10. Nope , not all techs have soldering irons , only...

    Nope , not all techs have soldering irons , only the Real Techs do ...




    :grin2:
  11. yup , just take the relays cover off and inspect...

    yup , just take the relays cover off and inspect the points. Nothing pops out , no tricks , its Real simple. One screw normally holds the top on. Some like to add a drop of sealant on the screw , a...
  12. Resistors keep points from arcing - welding...

    Resistors keep points from arcing - welding themselves together in sensors-relays, and it kills the charge in the cap so you dont get zapped.
  13. Replies
    15
    Views
    906

    I tellya how " i " did it. Went to a friend whos...

    I tellya how " i " did it. Went to a friend whos unit needs a 2 lb top off every single year. He keeps saying hes saving up for a new system... i knew that day wasnt coming soon, so i added leak...
  14. remove about 3 pounds , clean indoor coil and see...

    remove about 3 pounds , clean indoor coil and see how it runs

    If that dont solve it , remove it all , check piston for junk , may even have a screen
  15. Replies
    21
    Views
    567

    I was rushing the job and didnt even pay...

    I was rushing the job and didnt even pay attention to the piston number on ODU. Dam

    All I know is , renter is happy as a mosquito at a nudist colony right now ....
  16. Replies
    21
    Views
    567

    i didnt know they usually use a smaller piston,...

    i didnt know they usually use a smaller piston, so its probly over charged for winter. I will check it when i get slow
  17. Replies
    21
    Views
    567

    yea, ive known the guy for years, hes terrible w...

    yea, ive known the guy for years, hes terrible w money
  18. Replies
    21
    Views
    567

    Yea i went with 410 in the event it dont heat...

    Yea i went with 410 in the event it dont heat well i can just swap in a indoor unit to match, seeing its old as dirt, but for now renter is happy. Landlord is selling another house and will have...
  19. Replies
    21
    Views
    567

    I was in a hurry , have work up to my ears ,...

    I was in a hurry , have work up to my ears , slapped unit in place , checked low side after few minutes , its at 130 , outside 90 , inside 75 because they have window shakers , probly gonna freeze up...
  20. Replies
    21
    Views
    567

    How bout I wire it for heat strips only during...

    How bout I wire it for heat strips only during winter :grin2:
  21. Replies
    21
    Views
    567

    OlderCarrier Alum AH switching to 410

    Slumlord has old ass carrier , probly 1990 2 ton split

    OD unit shot

    Thought Id atleast get him into the 410 era

    Was thinking installing a 1.5 ton ODU onto the existing 2 ton aluminum evap...
  22. Replies
    4
    Views
    415

    if it's located somewhere it will never go above...

    if it's located somewhere it will never go above 75 degrees it's probably OK, but if its in a sweatbox kitchen you might consider replacing that motor

    As for checking head without guages, grab the...
  23. Thread: Death Trap

    by Snapperhead
    Replies
    47
    Views
    5,601

    http://hvac-talk.com/vbb/showthread.php?1512931-DI...

    http://hvac-talk.com/vbb/showthread.php?1512931-DIY-guy-smells-gas&highlight=smell+gas
  24. Replies
    7
    Views
    626

    Dam , that outter burner is over 200 bucks. New...

    Dam , that outter burner is over 200 bucks. New stove is 600 . Im gonna try to weld the hole. Its got one orafice that broke out leaving a dime size hole.
  25. Replies
    7
    Views
    626

    i need to slide back over and measure ring

    i need to slide back over and measure ring
  26. Replies
    7
    Views
    626

    looks about right , just have to measure it

    looks about right , just have to measure it
  27. Replies
    7
    Views
    626

    Name that Pot Stove

    need a burner for it
  28. Replies
    31
    Views
    1,099

    Hope you like Curry ....

    Hope you like Curry ....
  29. Replies
    31
    Views
    1,099

    That dam Protocol guy was right after all ...

    That dam Protocol guy was right after all :grin2: it could be wired 1 phase , its just not written out HOW to wire it that way.

    Im glad it had the choice of 3 phase though to reduce the amps in...
  30. Replies
    31
    Views
    1,099

    Thats funny , I've went over that diag 20 times...

    Thats funny , I've went over that diag 20 times and never noticed that !!
  31. Replies
    31
    Views
    1,099

    Jeeez I didnt even try that number , but youre...

    Jeeez I didnt even try that number , but youre right ...

    I will just call the local electric motor rebuilder monday
  32. Replies
    31
    Views
    1,099

    Well this diagram doesnt have 1 phase written on...

    Well this diagram doesnt have 1 phase written on it anywhere.

    If I had to use single phase , i would pull 8ga because im anal like that ....
  33. Replies
    31
    Views
    1,099

    I guess you could , but its working on 3 phase...

    I guess you could , but its working on 3 phase just fine. I just need to figure out whats the correct cap for the convection Blower Motor
  34. Replies
    31
    Views
    1,099

    I never said I was going to hook up single phase...

    I never said I was going to hook up single phase , You mentioned doing it , I pulled wire for THREE PHASE like the manufacturer intended.

    If I wanted to max out the wiring by pulling 28 amps...
  35. Replies
    31
    Views
    1,099

    Wired up 3 phase and it runs , but the fan motor...

    Wired up 3 phase and it runs , but the fan motor sounded slow starting , so i find someone took out the original capacitor and put in 7.5 run cap you would find on a cond fan motor

    Not sure if...
  36. Replies
    31
    Views
    1,099

    Protocol , you are confused like I was. There...

    Protocol , you are confused like I was.

    There is no Single phase on this unit, nor can it be wired as such.

    In USA , Single phase is 120 going to each leg and a "ground" to the units casing...
  37. Replies
    31
    Views
    1,099

    Interesting , guess Vulcan bought them out Yea...

    Interesting , guess Vulcan bought them out

    Yea i googled 2 phase , and each leg to N brings 220 , they just make the N alot bigger gauge wire since it carries both currents
  38. Replies
    31
    Views
    1,099

    im gonna wire it 3 phase and plugger on in .......

    im gonna wire it 3 phase and plugger on in .... its gotta have 120 on that one labeled N for the heaters to pull 220 , that cant be neutral ( i hope )

    hope it dont let the smoke out hehe

    its...
  39. Replies
    31
    Views
    1,099

    do they mean bring in 220 on 2 legs , and bring a...

    do they mean bring in 220 on 2 legs , and bring a neutral to third leg to have 120 volts on temp control ?

    But why do they have the N wire going to heaters ?

    Im so confused. It says nothing...
  40. Replies
    31
    Views
    1,099

    oven

    oven
  41. Replies
    31
    Views
    1,099

    How do you wire this Wolf Oven

    Never seen a " 2 phase " 3 wire ?? What is 2 phase ??

    But then drawing shows incoming wires going to a 3 wire terminal block , then to a 3 pole contactor

    I pulled 3 wires 10 ga , and a ground...
  42. Replies
    1
    Views
    358

    Henny Penny deep fryer

    What a muther to work on....

    Whoever the hell designed this thing , they need a good slap !
  43. Replies
    26
    Views
    1,356

    Is bulb clocked correctly ? Horizontal ? Mounted...

    Is bulb clocked correctly ? Horizontal ? Mounted close as you can get it ?
  44. Id say he will have plenty of heat ..... lol

    Id say he will have plenty of heat ..... lol
  45. Replies
    6
    Views
    411

    Id say either thermocouple bad , or the little...

    Id say either thermocouple bad , or the little points inside the relay burnt up
  46. Replies
    11
    Views
    671

    I had one like that , never did figure it out ,...

    I had one like that , never did figure it out , the customer just hits the reset like once a week , he didnt want a new board

    Acted like it was in test mode sometimes , it had a little micro...
  47. Replies
    56
    Views
    3,093

    Top picture aint no ducks head , thats a Boxing...

    Top picture aint no ducks head , thats a Boxing glove ! Notice its got a little extra lift on the very edge , pretty neat idea

    Bottom one is your ducks head , and it spins ccw just like the duck...
  48. Replies
    56
    Views
    3,093

    Doubt me if you like , its your call...

    Doubt me if you like , its your call...
  49. Replies
    41
    Views
    2,357

    Isnt it strange how a leaker is almost always...

    Isnt it strange how a leaker is almost always indoors... you only see cond leak when it rubs something, or discharge crack.

    Yea im surprised some jerk installed R22
  50. Replies
    41
    Views
    2,357

    5 year old Carrier leaking 22 ??

    Friend of a friend , elderly lady , says she paid a nice chunk to have a company top off her 5 ton unit AC , gas fired , he added 5 lbs and told her for another couple hundred he would look for the...
Results 1 to 50 of 1000