05-20-2013, 06:03 PM
Thread: Open Source Logic Controls
by simux- Replies
- 9
- Views
- 551
It really looks like Easy IO systems are the way...
It really looks like Easy IO systems are the way to go and all. Do they have distributers or will they sale the parts and software directly. Also how are the graphics?
-
05-20-2013, 05:48 PM
Thread: Who gets stuck being on call
by simux- Replies
- 62
- Views
- 3,271
Our maintenance staff gets 2 hours of comp time...
Our maintenance staff gets 2 hours of comp time for each day of being on call plus time and a half for being called out.
-
05-15-2013, 08:13 PM
Thread: JCI NCM Programming
by simux- Replies
- 7
- Views
- 308
I seem to remember that i had to upload my NCMs...
I seem to remember that i had to upload my NCMs after I made any changes so GPL could find the points.
-
05-15-2013, 08:05 PM
Thread: FAKE POINTS IN METASYS
by simux- Replies
- 4
- Views
- 177
You could search the GPL or JC basic files to see...
You could search the GPL or JC basic files to see if a point is shared to a point.
-
05-13-2013, 02:58 PM
Thread: NCM Battery
by simux- Replies
- 8
- Views
- 1,110
The NCM will only reload if there are no errors...
The NCM will only reload if there are no errors in the database. Been there, done that , got the t-shirt!!!
-
05-13-2013, 01:40 PM
- Replies
- 10
- Views
- 318
Sometimes sites have controllers that are not...
Sometimes sites have controllers that are not supported by an NAE. For example if you have DCM's then you are tied to an NCM,
-
05-03-2013, 03:58 PM
Thread: New JCI N2 hardware available yet?
by simux- Replies
- 14
- Views
- 574
What about using NCMs with PMI?
What about using NCMs with PMI?
-
05-03-2013, 03:56 PM
Thread: JCI NCM Programming
by simux- Replies
- 7
- Views
- 308
There's also an option to generate a bas file I...
There's also an option to generate a bas file I think. Then you can look at the code in jc basic.
-
04-26-2013, 03:16 PM
Thread: New JCI N2 hardware available yet?
by simux- Replies
- 14
- Views
- 574
What do you use to commission these new...
What do you use to commission these new controllers and how do they map into PMI???
-
04-19-2013, 04:35 PM
Thread: XBS uppgrade to EBI Honeywell
by simux- Replies
- 65
- Views
- 6,775
Would definately stay away from this scenario....
Would definately stay away from this scenario. The XBS and EBI don't tend to play well together. I can't wait to rip all the controllers out and start from scratch!!!!
-
04-17-2013, 04:41 PM
Thread: Johnson R26 step controller
by simux- Replies
- 2
- Views
- 152
I remember they put those controllers in boilers....
I remember they put those controllers in boilers. Anyways get a http://www.kele.com/transducers/res-1e.aspx and you can use a 0 - 10 volt signal to control the 135 ohm controller..
-
04-17-2013, 04:22 PM
Thread: Modem Config
by simux- Replies
- 7
- Views
- 263
If its to communicate with an older controller...
If its to communicate with an older controller you probably need to be on a certain comm port, usually com 1 or 2.
-
04-17-2013, 04:17 PM
- Replies
- 10
- Views
- 318
Also I agree with BillControls about the layering...
Also I agree with BillControls about the layering of an NAE on top of a NCM. Then you have to know both systems and troubleshooting is more difficult.
-
04-17-2013, 04:14 PM
- Replies
- 10
- Views
- 318
Smoke control processes can be an issue depending...
Smoke control processes can be an issue depending on different factors.
-
04-16-2013, 07:04 PM
Thread: New to Metasys (and HVAC), need advice
by simux- Replies
- 29
- Views
- 1,183
I would totally go that route, just make sure you...
I would totally go that route, just make sure you can send the NAE back if it doesn't work. You could configure the new controller on the N-2 buss and then put back the old NAE until your finished....
-
04-08-2013, 04:30 PM
Thread: Trane Tracer Summit odball...
by simux- Replies
- 20
- Views
- 770
What year is the generator. Back in the day we...
What year is the generator. Back in the day we had issues with shielding generators causing interference with electronics. Sometimes you could provide a better ground for the gen set and it would get...
-
04-08-2013, 04:22 PM
Thread: Newer Controllers on N2 Bus Wiring
by simux- Replies
- 13
- Views
- 608
I've seen distances of N-2 busses that would...
I've seen distances of N-2 busses that would stagger the mind and still work. Although I've had to make sure the shielding was correct and the distance between controllers not be too great. I would...
-
04-02-2013, 04:18 PM
Thread: Controls Representation
by simux- Replies
- 7
- Views
- 546
I also think most people moved on from pneumatics...
I also think most people moved on from pneumatics but quite a few people still respond to pneumatic questions. I thought maybe Honeywell prohibited their people from Hvac-Talk.
-
04-02-2013, 04:15 PM
Thread: Controls Representation
by simux- Replies
- 7
- Views
- 546
I was under the impression that there were quite...
I was under the impression that there were quite a few Honeywell systems installed all over the country in the 80's.
-
03-23-2013, 11:05 AM
Thread: Controls Representation
by simux- Replies
- 7
- Views
- 546
Sure
I just noticed we don't have the number of reponses on Honeywell that we do from other manufacturer lines. Then of course the conspiracy theory in me took over and I asked the question.
-
03-22-2013, 05:06 PM
Thread: Controls Representation
by simux- Replies
- 7
- Views
- 546
Controls Representation
I was wondering about the talent we have on HVAC Talk. It seems to me that pneumatics is well represented along with Johnson, Seimens, Trane etc... I was wondering about Honeywell, the "Big Red". It...
-
03-21-2013, 04:23 PM
- Replies
- 7
- Views
- 238
http://necc-controls.com/vav/kreuter-pneumatic-vav...
http://necc-controls.com/vav/kreuter-pneumatic-vav.html
-
03-21-2013, 04:18 PM
- Replies
- 7
- Views
- 238
Someone probably took out the reverse reset...
Someone probably took out the reverse reset volume regulator. This part reverses the signal and lets you set the minimum and maximum air flows
-
03-20-2013, 07:21 PM
Thread: Honeywell Guru's
by simux- Replies
- 2
- Views
- 292
366351
366351
-
03-20-2013, 07:08 PM
Thread: Honeywell Guru's
by simux- Replies
- 2
- Views
- 292
Honeywell Guru's
When we go into EBI alarm management of a R-7044 analog input, the alarm point value is shown as red dashes.