Search:

Type: Posts; User: AmincControls

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    17
    Views
    565

    Interesting, I never thought to do that. Didn't...

    Interesting, I never thought to do that. Didn't realize you could edit it like that. I'll have to try that later. Thanks for the info!

    Edit- actually I have a feeling it wouldn't break a thing....
  2. Replies
    17
    Views
    565

    I'm not even sure you can do that actually. Last...

    I'm not even sure you can do that actually. Last I checked you can't open a CCT .caf file in PCT or the other way around. The best I've been able to figure out is that you can open your .caf in CCT...
  3. Replies
    17
    Views
    565

    I don't think that's something JCI wants shared...

    I don't think that's something JCI wants shared online. You need to request it from
    JCI or your local ABCS.
  4. Replies
    17
    Views
    565

    If it's a floating point valve then it would be...

    If it's a floating point valve then it would be two binary outputs I believe. I got into controls only 7 years ago now though so I've never really had much chance to work with floating point...
  5. Replies
    2
    Views
    159

    Okay. That makes sense. Thanks for your help.

    Okay. That makes sense. Thanks for your help.
  6. Replies
    17
    Views
    565

    Depends on where it's reversed at. You said...

    Depends on where it's reversed at. You said Binary Output? What kind of actuator is it? For a reheat valve I'd expect that you should be using a modulating actuator and an Analog output.

    Assuming...
  7. Replies
    2
    Views
    159

    Delta GCL+ and Timers

    I'm learning GCL+ programming right now and I'm having a hard time figuring out how to write something that I know I can write fairly simply in other block programming languages by other...
  8. Replies
    5
    Views
    691

    Did you ever get this working? I am having the...

    Did you ever get this working? I am having the same problem you were having on 3.4.
  9. Replies
    10
    Views
    420

    I haven't got that far with it yet. I've only...

    I haven't got that far with it yet. I've only started playing with mobile px since yesterday. Based on what I've seen so far I think the answer is probably no. I could be wrong though.

    I think I...
  10. Replies
    10
    Views
    420

    FYI, It looks pretty much the same on an iPhone....

    FYI, It looks pretty much the same on an iPhone. You can pinch zoom on it and it looks completely normal.
  11. Replies
    10
    Views
    420

    Okay. I poked around some more and figured it...

    Okay. I poked around some more and figured it out. It works pretty well actually. Even with the old graphics. I was using the wrong graphics pane. The border pane doesn't work right. The scroll pane...
  12. Replies
    10
    Views
    420

    I'm pretty sure it's not going to make a...

    I'm pretty sure it's not going to make a difference whether I use the old or new graphics. I deleted absolutely everything on the page except the background pane window and it still stays small like...
  13. Replies
    10
    Views
    420

    I was planning to use the new kitpxgraphics that...

    I was planning to use the new kitpxgraphics that came out with 3.7. The one in the picture is the old style graphics copy and pasted onto a pane from the mobile.jar. I didn't really think that would...
  14. Replies
    10
    Views
    420

    Yes, at first the page was cutting off the edges...

    Yes, at first the page was cutting off the edges of the Px file and "fit ratio" fixed that problem. Now I just can't figure out how to fix this problem. It seems like I'm missing something obvious...
  15. Replies
    10
    Views
    420

    Mobile PX Graphics

    See attached pictures. I'm playing around with mobile graphics for a project coming up and I'm having a problem with the Mobile PX page showing up on an iPad really small. You can zoom in but it...
  16. Replies
    14
    Views
    1,847

    Yeah. Although I had a couple bugs that I never...

    Yeah. Although I had a couple bugs that I never had a enough time to sit down and work out. I ended up moving and took down the FX40 a while ago and haven't reinstalled it in the new house so it's...
  17. Replies
    14
    Views
    1,111

    Oh. Well. That's good to know. Thanks.

    Oh. Well. That's good to know. Thanks.
  18. Replies
    14
    Views
    1,111

    I was looking at the portable BACnet router by...

    I was looking at the portable BACnet router by CControls. It is powered by your USB port on your laptop. The BAC-5051 is DIN mounted you need a 24v transformer to power it. I needed something more...
  19. Replies
    14
    Views
    1,111

    If you can I'd suggest using VMWare instead of...

    If you can I'd suggest using VMWare instead of Windows Virtual PC. Microsoft hasn't updated Virtual PC in forever. It's slow and just not really supported well anymore. At least that's my experience....
  20. Replies
    14
    Views
    1,111

    My problem is I'm running virtual machines on my...

    My problem is I'm running virtual machines on my machine so I can have both PCT and CCT on the same laptop. The virtual machine has a problem using the host's internal Bluetooth and requires the use...
  21. Replies
    14
    Views
    1,111

    BASRTP-B and CCT/PCT

    Can someone tell me if they are using a BASRTP-B to download and commission controllers through the BACnet Router connection option in lieu of the BTCVT? I've been having Bluetooth problems on my...
  22. Replies
    5
    Views
    369

    It won't let you uninstall the baja jar. I tried...

    It won't let you uninstall the baja jar. I tried it a little bit ago. It has like 30 other jar files that are dependent on it. It will let you re-install though. I may end up trying a clean .dist...
  23. Replies
    5
    Views
    369

    I tried that already actually. I did a re-install...

    I tried that already actually. I did a re-install through software manager. Didn't help at all. I didn't uninstall it first though... I'm not sure that would make a difference though.
  24. Replies
    5
    Views
    369

    FX60 Application Failed (Halted)

    I have an FX60 that keeps getting "app failed". At first it had a bad bacnet.jar. I re-installed it through the software manager and then rebooted it. Now it is halting during startup of the station....
  25. Replies
    1
    Views
    462

    Metasys 7.0 Access from iPad

    I just NUTed an NAE55 to 7.0 and I was told that that this new version doesn't need Ready Access Portal to be able to access from an iPad. I'm having a hard time finding documentation that explains...
  26. Replies
    4
    Views
    618

    FX30 JCIStation Password

    This may be a stupid question... But I don't think it is. I've worked on a LOT of FX JACEs over the last few years and the default JCIStation user name and password has always been admin/"blank...
  27. Replies
    4
    Views
    381

    Cause FX Builder was so God like... I hated that...

    Cause FX Builder was so God like... I hated that garbage. I will say though that CCT/PCT is leagues better than FX Builder.
  28. Replies
    5
    Views
    335

    Okay... Yeah. That's not the way to go then. I...

    Okay... Yeah. That's not the way to go then. I have to redownload all of my VMA controllers anyways to fix something. I'll just add most of the logic to my VMA program. I used the mass controller...
  29. Good luck. Sounds like you are SOL. Reaper is...

    Good luck. Sounds like you are SOL. Reaper is right. You can't upload it and can't see what it's doing unless you have the original controller file. I'm so glad JCI decided to use the FEC line for FX...
  30. Replies
    5
    Views
    335

    So if I program in a system folder does each...

    So if I program in a system folder does each logic block count as an object towards my 5000 objects?
  31. Replies
    5
    Views
    335

    Never mind about the interlock object. I just...

    Never mind about the interlock object. I just found the equation syntax in the help pdf and that won't help me for what I want to do. There's other ways I can do it but I was hoping to find an easy...
  32. Replies
    5
    Views
    335

    NAE Programming Objects Help

    I'm looking to monitor the position of about 80 hot water valves and demand a boiler on anytime more than 3-5 of them are over a certain percentage open. I know I can use the Interlock object to...
  33. Replies
    4
    Views
    381

    CCT Display Idle Page!

    Why hasn't JCI fixed the Idle Page from going out of the order I set it in everytime I add a new point to the program?! This has been a problem for a long time and we are up to 10.0 now and it's...
  34. Replies
    14
    Views
    1,847

    I was planning on adding a moisture sensor at...

    I was planning on adding a moisture sensor at some point too. I just wasn't sure if I wanted to go through the trouble of running a cable through my yard back to the FX40 in the garage. This is the...
  35. Replies
    3
    Views
    330

    That may be where I end up with this but the job...

    That may be where I end up with this but the job is 4 hours away in the desert and in a building that has limited access so I would like to try walking a maintenance tech through it using the display...
  36. Replies
    3
    Views
    330

    N30 Edit Date/Time from LDT

    First off, I have limited experience with the N30s. I have a customer that is having a problem with a N30. They lost power to the panel and now the schedule is all messed up. I think what happened is...
  37. Replies
    27
    Views
    3,227

    Also, make sure that the station user name and...

    Also, make sure that the station user name and password you use to login to the Jace is the same as what you are using for your server. Set those user accounts on both Jaces and Server to a "Network...
  38. Replies
    27
    Views
    3,227

    Oh okay. I think I get what you are doing now....

    Oh okay. I think I get what you are doing now. You did set up your realms? I don't think what you are trying to do will work without a realm setup both on the Server and the Remote Jace. I think I...
  39. Replies
    27
    Views
    3,227

    I think you might be using the wrong sidebar in...

    I think you might be using the wrong sidebar in workbench. Up above the sidebar you have an option to select NAV, Pallete and something else. I forget what the other is called at the moment. I...
  40. Replies
    14
    Views
    1,847

    Good to know. I'll have to look into that. I have...

    Good to know. I'll have to look into that. I have AT&T Uverse. I read somewhere that they will unblock port 25 but they'll charge me some fee to do it. I have it partially working using my work's...
  41. Replies
    14
    Views
    1,847

    Actually married with a 3 year old. My wife...

    Actually married with a 3 year old. My wife wasn't too happy with me this weekend. She was upset that I was "working". It was difficult to explain to her how awesome it was going to be when I was...
  42. Replies
    14
    Views
    1,847

    FX40 Converted into Sprinkler Timer

    This isn't really an HVAC thing but it is an FX40 so I hope this is appropriate to post in this section...

    So I've had this goal ever since I bought my house 5 years ago that I was going to rip my...
  43. Replies
    4
    Views
    648

    I ended up resolving the issue by leaving the...

    I ended up resolving the issue by leaving the Jace at FX2.2 and removed a few modules that I wouldn't be needing to clear enough space for a station. Works fine. Now if I could only get the...
  44. Replies
    4
    Views
    648

    I can still access the Platform through an...

    I can still access the Platform through an ethernet connection and Workbench. Is there a way to do a clean install or downgrade without doing a serial connection?
  45. Replies
    4
    Views
    648

    Well it turns out I shouldn't have upgraded a...

    Well it turns out I shouldn't have upgraded a FX40 with standard memory to FX 2.2 (3.3.31). The highest version that is recommended is FX 2.1. That being said I need some recomendations on how to...
  46. Replies
    4
    Views
    648

    FX40 Filesystem Space Low

    545461

    I commissioned a FX40 from 3.0 to 3.3. In the process I managed to become dangerously close to filing up the filesystem space. I can't even transfer a station over now.

    How do I clean...
  47. Replies
    2
    Views
    446

    Yeah. I actually just figured this out a little...

    Yeah. I actually just figured this out a little bit ago. I never really paid much attention to the settings on the left much.

    Do you know how the Setpoint Differential works? I read the help file...
  48. Replies
    2
    Views
    446

    FEC PID Problems

    I have a problem with these PIDs. I am not using the Pre-Processors or the adaptive tuning because we used to have problems with the adaptive tuning. Instead we have chosen to stick to manual tuning....
  49. Replies
    4
    Views
    821

    I decided to take a chance and upgrade to a new...

    I decided to take a chance and upgrade to a new server version. Worst case scenario I just have to go back down to where I was and I'm out the upgrade cost. They have been asking me to move the...
  50. Replies
    4
    Views
    821

    I have considered just going ahead and doing the...

    I have considered just going ahead and doing the upgrade on the server up to 3.8 or whatever the current version is. The only thing I am worried about is compatibility problems with old FX-40s I...
Results 1 to 50 of 137
Page 1 of 3 1 2 3