  1. Replies
    94
    Views
    2,920

    I see MC run through SEALTITE all the time up...

    I see MC run through SEALTITE all the time up here, can you remark this? being its a conductor through a raceway
  2. Replies
    5
    Views
    491

    Man it sure is nice to have equipment manu....

    Man it sure is nice to have equipment manu. lurking around on here to help!! I think you need 6 outlets/ton, your suction pressure is going to run %15 lower like MIK said
  3. Replies
    13
    Views
    1,928

    city code wont let us use clear cleaner:( we have...

    city code wont let us use clear cleaner:( we have had this discussion at the shop multiple times.
  4. Replies
    13
    Views
    1,928

    this is the first system like this we have done,...

    this is the first system like this we have done, so their was a huge learning curve for all of us. The water lines were done by another company but we are responsible for all the rest of the flaws...
  5. Replies
    14
    Views
    900

    i have a system with a amvm and a 18 seer...

    i have a system with a amvm and a 18 seer communicating heat pump with a EWC communicating zone panel, in heating i have found that the heat pump's timing of turning the blower on in the furnace can...
  6. Replies
    13
    Views
    1,928

    not quite finished but close

    I didn't do the linesets those will be fixed first of next week and tiddy up the wiring.

    2 systems

    amvc95070
    tts038 climate master tranquility 27 (closed loop)
    honeywell HZ432 zone panel
    2...
  7. Sticky: Why have you not changed the design of the Amana...

    Why have you not changed the design of the Amana AMH inducer motor they fail at a year old, have been for 5 years and you are still giving me the same motor to replace it with. Make more of a robust...
  8. Replies
    7
    Views
    684

    i think i still have my trac pipe and wardflex...

    i think i still have my trac pipe and wardflex cards somewhere, should send the to the Smithsonian :LOL:
  9. Replies
    14
    Views
    900

    does it have a communicating air to air H.p.?

    does it have a communicating air to air H.p.?
  10. Replies
    14
    Views
    900

    you can program the new board without the chip if...

    you can program the new board without the chip if you have a communicating stat. I keep a CTK02 stat on my van just for this reason. i pull the connector off the old board...with it still connected. ...
  11. Replies
    31
    Views
    1,777

    this is very informative to a tech that hasn't...

    this is very informative to a tech that hasn't worked on any microchannel units yet, thanks a bunch.
  12. Replies
    20
    Views
    1,445

    I have installed a few FUJI's and serviced...

    I have installed a few FUJI's and serviced somewhere around 20, also own one in my own home. we are also an AMANA dealer so we are pushing DAIKIN, but i much prefer fujitsu due to my familiarity to...
  13. Replies
    7
    Views
    341

    Board's lots and lots of boards. Other than that...

    Board's lots and lots of boards. Other than that they are solid
  14. Replies
    16
    Views
    1,214

    I have had problems with the ptrap not having...

    I have had problems with the ptrap not having anything in it, it wont pull in the front cover plate switch and furnace fail to ignite. I found this more typical with the 3 and 4 year old units that...
  15. Replies
    16
    Views
    1,202

    I condemned 2 of them this week, the back cover...

    I condemned 2 of them this week, the back cover plate where the primary and secondary hook up had BIG holes in them.
  16. Replies
    16
    Views
    1,368

    these are great and were just on sale a t...

    these are great and were just on sale a t Johnstone by me a few weeks ago.
  17. Replies
    34
    Views
    2,218

    Surge, go big or go back to the shop. it doesn't...

    Surge, go big or go back to the shop. it doesn't matter which one you get as long as you get one.
  18. Replies
    34
    Views
    3,648

    http://www.lightmalls.com/sky-ray-stl-v2-cree-xml-...

    http://www.lightmalls.com/sky-ray-stl-v2-cree-xml-t6-1000-lumen-led-flashlight-2-18650-3-16340-3-cr123a
    This is a great Flood for working in dark crawl spaces or just low lit areas

    This is the...
  19. Replies
    26
    Views
    4,424

    I have been doing this 12 years and i don't even...

    I have been doing this 12 years and i don't even know what this is "hot wire anemometer" nor have i ever needed one...I don't think:)
  20. Replies
    4
    Views
    1,935

    i had this problem with one brand new out of the...

    i had this problem with one brand new out of the box and put on a intermittent pilot spark board and a new gas valve, homeowners are so much happier that they don't have to worry about the pilot...
  21. Replies
    24
    Views
    2,713

    help me understand you have the new board in it...

    help me understand you have the new board in it and it doesn't flash any codes? does the blower run at all with or without the fan switch "on"? and you disconnected the t-stat wire and jumped out r...
  22. Replies
    58
    Views
    8,105

    I love my UEI testers

    I love my UEI testers
  23. Replies
    18
    Views
    1,365

    I personally am a big fan of raypak,easy to work...

    I personally am a big fan of raypak,easy to work on and fairly easy to find parts for.
  24. Replies
    2
    Views
    372

    i just worked on one a few weeks ago, it amazes...

    i just worked on one a few weeks ago, it amazes me how long things last when quality is stood highest priority.
  25. Replies
    15
    Views
    1,074

    that's a good furnace for a barn, just put a new...

    that's a good furnace for a barn, just put a new filter and nozzle in it, adjust air and run it.