    When the unit runs with the panel off it will...

    When the unit runs with the panel off it will freeze due to low air flow. That unit requires the panel for proper air flow through the coil.
  2. Replies
    13
    Views
    434

    Darn it! I'm outta info for that job.

    Darn it! I'm outta info for that job.
  3. Replies
    13
    Views
    434

    I never had to remove the heaters as the blower...

    I never had to remove the heaters as the blower housing stayed in place.
    I tried to get a picture of the assembly but the only PDF is install of the unit.
  4. Replies
    13
    Views
    434

    You have to remove the motor mount screws and...

    You have to remove the motor mount screws and then remove the cut-out ring screws and the motor, wheel and cut-out ring come out of the blower housing together. I have replaced a number of these over...
  5. Replies
    22
    Views
    741

    My vote.

    My vote.
  6. Replies
    37
    Views
    1,139

    You need to really check the wire diagram close....

    You need to really check the wire diagram close. Sounds as if it is miss wired.
  7. 16x25 is the size listed on the website.

    16x25 is the size listed on the website.
  8. X2

    X2
  9. Replies
    10
    Views
    722

    The outdoor weather you list is just like we have...

    The outdoor weather you list is just like we have here on the gulf coast area. I can't run heat pump defrosts at 90 minutes because the pump will not defrost. I have to run them all at 60 minutes so...
  10. Replies
    47
    Views
    3,466

    A helper with tools!!!!!!!!!!!

    A helper with tools!!!!!!!!!!!
  11. Replies
    30
    Views
    2,570

    I would check the metering device as it may be...

    I would check the metering device as it may be not seated properly in the fitting and bypassing refrigerant.
  12. Replies
    4
    Views
    534

    Coil install manual, page 5

    Coil install manual, page 5
  13. Replies
    4
    Views
    534

    As long as they installed the required spacer...

    As long as they installed the required spacer between the coil and furnace there should be no problems.

    The spacer should be shop or field fabed and at least 6 inches long.
  14. Replies
    5
    Views
    777

    The ecm motors do have a larger amp draw when...

    The ecm motors do have a larger amp draw when powered on. They have dc capacitors that have to charge each time power comes on and could be over the LRA of your controller relay.
  15. Replies
    4
    Views
    442

    Not always, I worked on a xb13 today with a recip...

    Not always, I worked on a xb13 today with a recip in it.
  16. Replies
    8
    Views
    368

    Try X13650941-010, That should be the CCP without...

    Try X13650941-010, That should be the CCP without display.
  17. That is a filter drier installed before the...

    That is a filter drier installed before the expansion valve and it looks as if it has been replaced. You may want another tech as this one seems confused.
  18. Replies
    64
    Views
    5,032

    I have it on a YJ titan four valve, but do not...

    I have it on a YJ titan four valve, but do not use the vacuum port it is capped. The AK900 lines up with the gauge ports so no extra fittngs.
  19. Replies
    9
    Views
    500

    A lot of manufactures don't put heaters on the...

    A lot of manufactures don't put heaters on the compressors and only suggest them when line set lengths get excessive.
    Unless your lines are going to be very long there should be no worries about...
  20. Replies
    64
    Views
    5,032

    I own three digital sets: 1- Cooper...

    I own three digital sets:

    1- Cooper MFM300-kit4, used mainly on critical charged systems. Does a good job, and will data log temperature with mini loggers.

    2- Testo 560 with wireless...
  21. Replies
    9
    Views
    1,072

    Before I tried to recondition any flooded...

    Before I tried to recondition any flooded equipment I would check with the Manufacture first.

    After Rita in 2005 our company received a letter from Trane through our distributor, that said any...
  22. Replies
    27
    Views
    3,309

    I think the model heat pumps you listed are all...

    I think the model heat pumps you listed are all two stage.
  23. Replies
    12
    Views
    1,498

    I have had two failures on t he new trane coils...

    I have had two failures on t
    he new trane coils since 2006 and one was operator induced. They are very dependable in my opinion.
  24. Replies
    48
    Views
    4,715

    I would have to check the piston as it looks like...

    I would have to check the piston as it looks like it is stuck in the fitting and bypassing refrigerant. Sometimes I have been able to seat them by rapping on the FCCV with the handle of a wrench.
    ...
  25. Thread: Any Ideas?

    by Tjune54
    Replies
    7
    Views
    842

    That is a scroll compressor and the dome is...

    That is a scroll compressor and the dome is discharge pressure and temperature.
    It should be too hot to touch or hold on to. I actually belive it is an unloading scroll on a two stage unit.