  1. We service just under 200 stores and about 8...

    We service just under 200 stores and about 8 different chains. We have more old stores than new. We are very busy (only had 2 days off this month)
  2. Replies
    13
    Views
    661

    I have a fieldpiece SC56 that is used 90% of the...

    I have a fieldpiece SC56 that is used 90% of the time.i also have a Fluke 87V

    I use a copper blue box for air and water temps.

    AK900 for pipe temps.
  3. I think I've only seen maybe 3 or 4 WIF without a...

    I think I've only seen maybe 3 or 4 WIF without a door switch.
  4. Replies
    51
    Views
    1,572

    I was actually eyeballing that last week. I might...

    I was actually eyeballing that last week. I might pick it up before the end of the month :)
  5. Replies
    51
    Views
    1,572

    I'm not concerned with mixing refrigerants and...

    I'm not concerned with mixing refrigerants and oils with my gauges.
    I just purge with nitrogen.
  6. Is it in a defrost Is the coil getting cold...

    Is it in a defrost
    Is the coil getting cold enough
    Is the klixon mounted properly
  7. Replies
    1
    Views
    372

    Are the only differences between it and the SC56...

    Are the only differences between it and the SC56 the lead parks and the magnet?
  8. Replies
    51
    Views
    1,572

    A full set up of the iManifold will run u closer...

    A full set up of the iManifold will run u closer to $1600 if u want to run it at its full potential. I'm saving for one and also waiting to see what Digi-Cool is working on.
  9. Replies
    29
    Views
    1,322

    It's amazing how fast the oil gets foggy on this...

    It's amazing how fast the oil gets foggy on this machine. I had one at my old company.
  10. Replies
    24
    Views
    720

    Thank you This is the kind of info I was...

    Thank you

    This is the kind of info I was looking for. I would love to not choke off a 7CFM pump and I thought it would take two 3/4" hoses. If it is a noticeable difference I will get them.
  11. Replies
    24
    Views
    720

    Good point. Would be nice if manufactures have...

    Good point.
    Would be nice if manufactures have that spec.
  12. Replies
    24
    Views
    720

    Thanks Jim that clears it up for me. Some people...

    Thanks Jim that clears it up for me. Some people tried to explane that earlier but the way you worded made more sence (to me).I didn't realize that the molecular flow is so low after the initial...
  13. Replies
    5
    Views
    285

    Thinking of selling one of my spare cars for a...

    Thinking of selling one of my spare cars for a Fluke TI32
  14. Replies
    5
    Views
    285

    I would look at getting a real thermal imager. ...

    I would look at getting a real thermal imager.

    The flir I4 ($900) is exactly the same as the Flir I8 ($6000). To save money Flir made all their new "I" series cameras the exactly the same on the...
  15. Replies
    24
    Views
    720

    You are correct that my terminology is off with...

    You are correct that my terminology is off with the "CFM". I guess I am technically looking for mass flow.

    I simply what to know what size hoses to I would need to be able to use a 10CFM or 12CFM...
  16. Replies
    24
    Views
    720

    I believe the hose diameter to CFM is somewhere...

    I believe the hose diameter to CFM is somewhere in there.

    I'll read it over tonight. Thank you.
  17. Replies
    24
    Views
    720

    I actually read the first link with the square...

    I actually read the first link with the square root vacuum pump rule of thumb sizing you posted and almost shot myself :)

    Thanks for the new link!!!!!
  18. Replies
    24
    Views
    720

    So no one know the CFMs the hoses I listed will...

    So no one know the CFMs the hoses I listed will allow through?

    I remember hearing somewhere that two 1/2" hoses will pull 16 times faster than two 1/4" hoses.

    For some reason I think a 1/4"...
  19. Replies
    24
    Views
    720

    You're answering a question I didn't ask. I...

    You're answering a question I didn't ask. I understand how vacuum pumps work and that I will never achieve more CFM than the pump is capable of.

    I'm asking for the CFMs through different diameter...
  20. Replies
    24
    Views
    720

    Where is the Appion guy or Jim?

    Where is the Appion guy or Jim?
  21. Replies
    24
    Views
    720

    Evacuation: hose diameter to CFM

    Does anyone know what the maximum CFM the following hose diameters are capable of (with schraders and depressors removed)

    A single 1/4" hose
    A single 3/8" hose
    A single 1/2" hose
    A single 3/4"...
  22. Good call going to one screen with no toggling...

    Good call going to one screen with no toggling IMO.

    Are there any upgrades other than the all in one screen over the Sman3?
  23. Replies
    8
    Views
    450

    Where did you buy it from?

    Where did you buy it from?
  24. Get a chance to play with it yet?

    Get a chance to play with it yet?
  25. Replies
    6
    Views
    481

    Test the meter against your daily driver on a...

    Test the meter against your daily driver on a couple parameters.
Results 1 to 25 of 500