  2. Thread: wye-delta

    by jsherhvac
    Replies
    14
    Views
    2,037

    Are you sure you said what you meant to say?? If...

    Are you sure you said what you meant to say?? If so please explain to me what takes place as far as contactor sequencing in the wye configeration to start chiller.
  3. Replies
    20
    Views
    1,980

    Thanks for all of the replies.:CU:

    Thanks for all of the replies.:CU:
  4. Thread: WHAT IF??

    by jsherhvac
    Replies
    26
    Views
    2,634

    WHAT IF??? We just used air cooled equipment:LOL:

    WHAT IF??? We just used air cooled equipment:LOL:
  5. Replies
    20
    Views
    1,980

    Service Tech Generated Revenue

    I was wondering if there was a good rule of thumb on much revenue a tech should produce in say a year. I understand this is probally not the best forum to post this question in, but was interested in...
  6. Replies
    3
    Views
    534

    What about renting the hose & victalic couplings...

    What about renting the hose & victalic couplings from Trane Chiller Source, just pass the cost on to the customer then you are not stuck with the hose at the end of the job. Just an idea.
  7. If you were talking to me, no I do not have any...

    If you were talking to me, no I do not have any 19DH literature. Try carrier.com more than likely the literature is there just tough to find on thier site sometimes.
  8. Replies
    26
    Views
    2,482

    Just wanted to say thanks for everyone's input. I...

    Just wanted to say thanks for everyone's input. I told the customer about changing dip switch on ccp1 to disable ground fault, they changed compressor has running fine for three days now. We are...
  9. Been trying to send email for 20 minutes now, my...

    Been trying to send email for 20 minutes now, my outlook is not working.
  10. The shaft shoulder measurement has everything to...

    The shaft shoulder measurement has everything to do with the contact seal. In other words thats the main reason for this measurment.
  11. Just wondering, have there been any seal problems...

    Just wondering, have there been any seal problems with the machine. The email is on the way, sorry its taking so long to get back to you, these 12-14hr. days are begining to wear on me.
  12. There is a spacer on the thrust end that can be...

    There is a spacer on the thrust end that can be machined to get your shaft shoulder to casing measurment correct. Did you have to replace the rotor assembley, if so your new rotor is probably a...
  13. Replies
    16
    Views
    2,031

    Hey ChillerWisperer did your quote/signature come...

    Hey ChillerWisperer did your quote/signature come from Dave at LaCrosse?
  14. I have qite a bit of literature, all from...

    I have qite a bit of literature, all from carrier.com which you probably already have. If you have any questions I could probably help. I have done 2 17ma40 rebuilds & probably 10-15 17s30 rebuilds...
  15. Replies
    26
    Views
    2,482

    Thank you kind sir.:D I had the literature...

    Thank you kind sir.:D I had the literature already just didn't see the note about the dip switch setting. I must of had my head up my butt. Thanks Again
  16. Replies
    26
    Views
    2,482

    [QUOTE=thegoodlistener;3859022]The info to...

    [QUOTE=thegoodlistener;3859022]The info to disable the ground fault is in the literature , I honestly have never had to do it.

    I could not find anything on disabling the ground fault in the...
  17. Replies
    26
    Views
    2,482

    The literature says "detected current to ground...

    The literature says "detected current to ground 2.5 amps +/- 2 amps" = ground fault alarm.
  18. Replies
    26
    Views
    2,482

    [QUOTE=thegoodlistener;3859022]The info to...

    [QUOTE=thegoodlistener;3859022]The info to disable the ground fault is in the literature , I honestly have never had to do it.

    I will read up on that thanks for the info. If you think of anything...
  19. Replies
    26
    Views
    2,482

    Thanks for the info, and yes I megged motor all...

    Thanks for the info, and yes I megged motor all six leads to ground and all leads to each other just to be sure.
  20. Replies
    26
    Views
    2,482

    No I have not, I was not aware I could do that. ...

    No I have not, I was not aware I could do that. Do you happen to have any literature on the chiller. I downloaded what I could off of the carrier site.
  21. Replies
    26
    Views
    2,482

    The version 26 board is for the compressor that...

    The version 26 board is for the compressor that is tripping.
  22. Replies
    26
    Views
    2,482

    Chiller#2 M/N 30HXC206RY-540BA S/N 0702Q01190

    Chiller#2 M/N 30HXC206RY-540BA S/N 0702Q01190
  23. Replies
    26
    Views
    2,482

    CCP board 1 for compressors a1 & b1 which was...

    CCP board 1 for compressors a1 & b1 which was recently changed is rev. 26
    CCP board 2 for compressor a2 which came on machine from factory is rev.23
  24. Replies
    26
    Views
    2,482

    Exv position was around 47%, I did ohm out the...

    Exv position was around 47%, I did ohm out the exv, checked perfect per the literature I have (25 ohms +/- 2 ohms I believe it was) also watched voltage go up and down as motor opened and closed
  25. Replies
    26
    Views
    2,482

    Customer has already replaced torrid sensor(sorry...

    Customer has already replaced torrid sensor(sorry I referred to as CT) but I will take another look at that. Thanks for the help.