05-17-2013, 01:24 PM
Thread: PCG Sequencer
by sycontrol- Replies
- 1
- Views
- 111
Do you have a JACE (fx 20 or 60) that you could...
Do you have a JACE (fx 20 or 60) that you could put a rotate schedule in. You could link the output from the schedule to the input.
-
04-17-2013, 02:44 PM
- Replies
- 10
- Views
- 205
When in commissioning mode in PCT for the binary...
When in commissioning mode in PCT for the binary output you see that the application says the output on "on" but the value beside HW: is "OFF". Is that point in PCT an orange color indicating that...
-
04-14-2013, 09:04 PM
- Replies
- 5
- Views
- 199
Make your sequence an Activity Output of the...
Make your sequence an Activity Output of the correct type (enum,boolean,float) and expose it for connection in the connections of the tab of that block. From there you can use it where ever you want...
-
04-14-2013, 01:50 PM
- Replies
- 5
- Views
- 199
What type of error are you getting? You are...
What type of error are you getting? You are using the output for the PID to the input of the sideloop in the same controller? IF it is saying circular dependency the use a last value (LV) block.
-
02-28-2013, 10:37 AM
Thread: PCV1620 and bacnet device instances
by sycontrol- Replies
- 4
- Views
- 194
In my notes from PCT class I wrote the only way...
In my notes from PCT class I wrote the only way to fix this issue was to download the controllers again.
-
02-22-2013, 02:59 PM
- Replies
- 10
- Views
- 453
I had the same issue. We put a UPS on the JACE...
I had the same issue. We put a UPS on the JACE and that solved that pesky problem.
-
02-17-2013, 11:26 PM
Thread: Bacnet MS/TP Max master
by sycontrol- Replies
- 7
- Views
- 309
Thanks for setting me straight. I thought, in...
Thanks for setting me straight. I thought, in error, that it was the number of devices not the address of said devices. Now that makes a little more sense. Thanks for the link as well ewang.
-
02-16-2013, 12:34 PM
Thread: Bacnet MS/TP Max master
by sycontrol- Replies
- 7
- Views
- 309
Bacnet MS/TP Max master
I have read that in a FX JCI JACE that the default max masters is set to 127 and that by decreasing that number to the number of devices on the trunk you can gain a little performance. I have 3...
-
02-10-2013, 09:28 PM
Thread: FX-PCV1620 question
by sycontrol- Replies
- 13
- Views
- 350
From JCI doc on what it takes to make the PCV go...
From JCI doc on what it takes to make the PCV go into WC-C of warm up:
WarmupCooldown Determination
This module determines the effective WarmupCooldown status for single duct VAV applications by... -
01-31-2013, 09:12 AM
- Replies
- 21
- Views
- 818
I have Trane bacnet VAV UC400 controller that is...
I have Trane bacnet VAV UC400 controller that is doing similar things. when it goes from unocc to occ it's like it gets lost in its calibration. the graphic will show the damper at 100% but the...
-
01-28-2013, 02:53 PM
Thread: varitrac comfort manager cable
by sycontrol- Replies
- 2
- Views
- 190
Got it! Many thanks!
Got it! Many thanks!
-
01-28-2013, 02:16 PM
Thread: PCA Controllers
by sycontrol- Replies
- 2
- Views
- 165
I just asked my rep that question yesterday. He...
I just asked my rep that question yesterday. He told me around March they should be release.
-
01-28-2013, 12:05 PM
Thread: varitrac comfort manager cable
by sycontrol- Replies
- 2
- Views
- 190
varitrac comfort manager cable
I am trying to connect to an old varitrac (don't know if its a I or II). I have found lots of post of baude rates and flow control and the like. When we ordered the connectors for the varitrac...
-
01-13-2013, 10:50 PM
Thread: Alerton AX Driver
by sycontrol- Replies
- 6
- Views
- 331
I have a FX JACE on a couple Alerton Bacnet...
I have a FX JACE on a couple Alerton Bacnet controls and it works just fine. It discovered the controllers and points. You will need to know the BV and AV as they pull as just that AV and BV.
-
01-04-2013, 03:17 PM
- Replies
- 20
- Views
- 1,121
If you are using a JACE and it has internet...
If you are using a JACE and it has internet access the weather service has a sunrise/sunset time that you could possible use?
-
12-23-2012, 08:22 PM
Thread: Collect history on button push
by sycontrol- Replies
- 3
- Views
- 336
Anyone have any ideas? I'm still searching out...
Anyone have any ideas? I'm still searching out ways to try to do this.
-
12-21-2012, 09:07 AM
Thread: Collect history on button push
by sycontrol- Replies
- 3
- Views
- 336
Collect history on button push
Is it possible to create a history record when a button is pushed? I have a timer that enables a label to promt the service guys to check the filters. There are 2 buttons one for filter check and...
-
12-19-2012, 11:03 PM
Thread: Weather jar issue
by sycontrol- Replies
- 5
- Views
- 714
Dapper not sure i undetstand. I upgraded all out...
Dapper not sure i undetstand. I upgraded all out of date jar files on the jace. Not sure what distribution files you are talking about.
-
12-19-2012, 12:02 PM
Thread: Weather jar issue
by sycontrol- Replies
- 5
- Views
- 714
Yes. Weather.jar is loaded on the FX. If I go...
Yes. Weather.jar is loaded on the FX. If I go to a WB version 3.0 the weather service works on the same station as it should. Must be a WB issue or software installation issue?
-
12-18-2012, 09:50 PM
Thread: Weather jar issue
by sycontrol- Replies
- 5
- Views
- 714
Weather jar issue
I just upgraded an FX20 to use the weather jar version 3.6.47. When I drop the weather service from the pallet tot the services under the station. When I double click on it to set it up I get an...
-
12-12-2012, 08:20 PM
Thread: Trane Varitrac III CCP
by sycontrol- Replies
- 4
- Views
- 504
Thanks guys. I will see if the reboot will help...
Thanks guys. I will see if the reboot will help the ccp. If not I guess I will have to replace it.
-
12-12-2012, 02:00 PM
Thread: Trane Varitrac III CCP
by sycontrol- Replies
- 4
- Views
- 504
Trane Varitrac III CCP
Got called to a site today to look at a trane CCP. Not that familure with them but this doesn't look to promising. the display had under the diagnostics. 1. CCP Eprom write fail
Does this mean... -
12-06-2012, 12:32 PM
- Replies
- 25
- Views
- 956
are you hooking the front end to the supervisory...
are you hooking the front end to the supervisory link? does it have a display where you can disconnect the front end and manually override from the controller?
-
11-29-2012, 03:00 PM
- Replies
- 6
- Views
- 768
That's nice to know. In this case we set a new...
That's nice to know. In this case we set a new dedicated transformer for the controller.
-
11-29-2012, 10:40 AM
- Replies
- 6
- Views
- 768
Thanks for the niagara link. That was some...
Thanks for the niagara link. That was some interesting reading. Now to see if I can make the issues go away. Of course the customer says it didn't do this until I put the new controller on the...