    It took 65 seconds for my furnace to use one...

    It took 65 seconds for my furnace to use one cubic foot of gas. Which equals 55 cubic feet per hour. Which equals 52061 btu/hr. Pretty close to the name plate input rating of the furnace.

    What...
  2. Replies
    11
    Views
    1,530

    On low fire, which is where I have it locked for...

    On low fire, which is where I have it locked for the fall, its 52K input. That's 55.3 cfh. Its getting cold enough for me to actually clock it.
  3. Replies
    11
    Views
    1,530

    I will agree that I'm probably not getting 96.6%...

    I will agree that I'm probably not getting 96.6% efficiency. That's why carrier stated "up to" 96.6% efficient. But the lower flue temperature proves more of the BTU's are remaining in my home.....
  4. Replies
    11
    Views
    1,530

    Placing my hand on the pvc flue would immediately...

    Placing my hand on the pvc flue would immediately inform me that my 96.6% is more efficient than my old 80% furnace without any calculations because I wouldn't have a blister. No?

    The 58MVP is "up...
  5. Replies
    11
    Views
    1,530

    New gas meter=higher bill?

    I installed a new carrier 58MVP 75K furnace. It kept locking out so the outfit which sold it to me instructed to have the gas pressure checked. When Mid-America checked the pressure, they also...
  6. Replies
    4
    Views
    1,360

    high efficiency gas furnace. And water heater. ...

    high efficiency gas furnace. And water heater. Both sealed combustion.
  7. Replies
    4
    Views
    1,360

    Thanks Teddy. Quite honestly. Every so called...

    Thanks Teddy. Quite honestly. Every so called professional Iv invited into my home was a joke.
    Yes I know WHF's are borderline in my area and my A/C does get used more since it pulls only a few...
  8. Replies
    4
    Views
    1,360

    Help me design a whole house fan which works.

    I bought a home with a damaged ceiling in the center of the living room. I decided to use some spare parts I had to make a whole house fan instead of repairing the ceiling. I used a 18" round hart...
  9. Replies
    22
    Views
    2,088

    The WR 95 series was sounding like a possibility...

    The WR 95 series was sounding like a possibility until I started to read the reviews.

    "the problem with a lot of electronics today is the life span of the electrolytic capacitors in the...
  10. Replies
    22
    Views
    2,088

    Yea Im not worried about cost. You usually get...

    Yea Im not worried about cost. You usually get what you pay for.

    Can you recommend a stat which has a outdoor sensor which locks out W2 and is user friendly before I start searching?
  11. Replies
    22
    Views
    2,088

    I tore out a 120K and replaced it with 75K. 4...

    I tore out a 120K and replaced it with 75K. 4 ton down to 2.5 condenser, 3 ton coil. 2600 square feet 70's 2x4 construction. I winged it.. No manual J

    I like that idea about a outdoor stat...
  12. Replies
    22
    Views
    2,088

    Yup, found the switch now.. SW-2 needs to be on...

    Yup, found the switch now.. SW-2 needs to be on for two stage. Thanks dunkman.




    My home is a split foyer/level home with a louver door on the furnace room. When high heat kicks in, it sounds...
  13. Replies
    22
    Views
    2,088

    Please correct me if Im wrong.. If I only...

    Please correct me if Im wrong..

    If I only have W1 energized with my T87 single stage stat. And first stage heat starts up, and then after 16 minutes second stage heats kicks in without the...
  14. Replies
    22
    Views
    2,088

    Best stat for a 2 stage furnace.

    I'm trying to find a new thermostat for my carrier 58MVP furnace to replace my single stage Honeywell T87. The 90%+ Furnace has variable speed blowers and 2 stage heat. I under sized my A/C to...
  15. Replies
    7
    Views
    2,934

    I think we are talking about the same thing...

    I think we are talking about the same thing except for the hinge location. The 16 gage was only a thought because I know it will want to flop around with the amount of air passing by it.

    Is this...
  16. Replies
    7
    Views
    2,934

    I guess I still dont see a leaf damper in there. ...

    I guess I still dont see a leaf damper in there. Im just going with the images I find when I goggle leaf damper and splitter damper.

    Heres my first attempt with sketchup
  17. I know you didnt have this option. But ground...

    I know you didnt have this option. But ground source heat pumps or geothermal heat pumps rock.

    One of the best ones IMO..

    http://www.earthlinked.com/residential
  18. Replies
    7
    Views
    2,934

    Thanks Deejoe. Heres a pic. Its a typical...

    Thanks Deejoe.

    Heres a pic. Its a typical residential install. I did raise the coil so I could see it from the bottom. 18x8 taken off the front and 14x8 off the back. I need to completely block...
  19. Replies
    7
    Views
    2,934

    plenum splitter design & linkage

    Hi , new here. Been employed in the hvac industry for over 20 years.:patriot:

    Iv been brainstorming how to install a easily actuated duct damper to balance, or isolate half of my split level...