    System was properly evacuated and purged while...

    System was properly evacuated and purged while brazing.
    How do you test for non condensibles
  3. Replies
    12
    Views
    534

    Fluctuating refrigerant pressures

    We were doing a start up on a Bryant A/C system that we installed today and after 5 minutes of running the low side was fluctuating between 110 to 125 psi and the high side was fluctuating between...
  4. Replies
    5
    Views
    522

    Triangle duct box in attic

    I have been doing some work in a newer development where all of the hvac equipment and duct work is in the attic. Whoever did the ductwork used triangle duct boxes. They used 10 inch supllies off...
  5. Replies
    2
    Views
    389

    Best flow hood for residential

    What is the best flow hood for residential air measurements?

    What price should I expect to pay?

    I was looking at the Alnor flow hoods online. Are they the best ones if so what model
  6. Replies
    40
    Views
    4,560

    It's looks like you only used 3/4 pipe coming off...

    It's looks like you only used 3/4 pipe coming off the top of the boiler, the smallest pipe that Weil McLain wants to see coming off the boiler is 1 inch. That boiler might be over heating in the...
  7. Replies
    13
    Views
    2,154

    lol

    lol
  8. Looking for a Minneapolis duct blaster system

    Im looking for a Minneapolis duct blaster system. I have to take my BPI field test in a few weeks and I need this equipment for my test. If anyone has one for sale and its in good condition email...
  9. Replies
    44
    Views
    4,947

    Well, im starting my blog tomorrow. "If you have...

    Well, im starting my blog tomorrow. "If you have a CO detector thats over 2 years old throw it away and get a new one. Bob's from Georgia and Hambone from Utah says their no good after 2 years"
  10. Replies
    39
    Views
    7,099

    Install overall looks pretty good. But with all...

    Install overall looks pretty good. But with all of that 3/4 pvc tied into one primary 3/4 pvc pipe your begging for trouble.

    Those humidifier pads break down and are going to plug up in all of...
  11. Replies
    44
    Views
    4,947

    (I trust my life on a 50 dollar plastic battery...

    (I trust my life on a 50 dollar plastic battery operated box when it comes to CO detection and so does most of the American public.)
  12. Replies
    47
    Views
    7,175

    I like the black mold on the wall.

    I like the black mold on the wall.
  13. Replies
    9
    Views
    1,757

    At least they leveled it.

    At least they leveled it.
  14. Replies
    11
    Views
    2,210

    Looks good. Im glad to see you guys installed...

    Looks good. Im glad to see you guys installed traps in the suction lines.
  15. Replies
    41
    Views
    40,389

    I love the Fujitsu's. Also check their website. ...

    I love the Fujitsu's. Also check their website. Some of their heat pump systems qualify for the energy tax credit.
  16. Replies
    23
    Views
    3,450

    No we haven't had any problems. Its only a...

    No we haven't had any problems. Its only a 70,000 BTU furnace and the install instructions called for 2" pipe so that what we installed.

    We have installed hundreds of Goodman systems over the...
  17. Replies
    23
    Views
    3,450

    Its a 3.5 ton A/C system.

    Its a 3.5 ton A/C system.
  18. Replies
    23
    Views
    3,450

    95% Goodman installation

    We took out this rust bucket and intalled a Goodman GMH95. Im happy with the way it came out and so was the customer.
  19. Thread: Job pictures

    by nortonma
    Replies
    14
    Views
    3,613

    I think a mini-split heat pump would of been...

    I think a mini-split heat pump would of been their best option.
  20. Replies
    3
    Views
    1,111

    Email me when you get a chance

    Email me when you get a chance
  21. Replies
    3
    Views
    1,111

    12 jugs of R-22 for $1500

    Im way overstocked on R-22. I bought 3 skids last summer and I only used 10 so far. Im located in S. Jersey and willing to deliver up to 30 miles. If interested email is in profile.
  22. Replies
    35
    Views
    6,676

    I would of used a 3/8 pipe bender rather than...

    I would of used a 3/8 pipe bender rather than brazing in all of those elbows, but still not a bad job overall.
  23. Replies
    63
    Views
    9,812

    I think you are lying that this is your first...

    I think you are lying that this is your first boiler install.

    You did a excellent job
  24. Replies
    10
    Views
    698

    Dallas sucks Romo is a Homo

    Dallas sucks Romo is a Homo
  25. Replies
    27
    Views
    4,846

    OPTICAL ILLUSION girl feet, guy pants = shemale

    OPTICAL ILLUSION

    girl feet, guy pants = shemale
Results 1 to 25 of 416
Page 1 of 17 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event