Search:

Type: Posts; User: gm-1978

Search: Search took 0.00 seconds.

  1. Replies
    15
    Views
    1,780

    Good Morning, I Was wondering what manufacture...

    Good Morning,
    I Was wondering what manufacture Generator Did Publix purchase.




    thanks
  2. Replies
    33
    Views
    4,608

    unions

    Gentleman,
    this is my opinion only reguarding Building Trades Journeyman. If one thinks That unions and Journeyman Market Techs need some Fine Tuning, Just Remember the Corporate CEOS that are in...
  3. Replies
    33
    Views
    4,608

    condensedave, thanks for your reply. gm-1978

    condensedave,
    thanks for your reply.


    gm-1978
  4. Replies
    33
    Views
    4,608

    hiltontech, thanks for your kind reply. ...

    hiltontech,
    thanks for your kind reply.



    Take care,
    Gm-1978
  5. Replies
    33
    Views
    4,608

    condensedave, Thanks for your comment about me....

    condensedave,
    Thanks for your comment about me.
    no problem.

    gm-1978.

    [Edited by gm-1978 on 06-21-2005 at 05:24 PM]
  6. Replies
    33
    Views
    4,608

    Sir, Also UA Local 38 in SF, IS At $42.00 per...

    Sir,
    Also UA Local 38 in SF, IS At $42.00 per Hour plus Benefits. Building Trades Journeyman Certified
    For Supermarkets Is a Grueling Specialty.

    GM-1978

    [Edited by gm-1978 on 06-21-2005 at...
  7. Replies
    33
    Views
    4,608

    Pay.

    Deleted by request from the poster.

    BC-1

    [Edited by BC1 on 06-21-2005 at 11:13 AM]
  8. Replies
    6
    Views
    1,124

    Hussmann Doors

    condensedave,

    Ha ha ha.



    gm-1978
    Pacific Refrigeration, inc.(Division service manager)
    Former, 2467 Hussmann.
  9. Replies
    6
    Views
    1,124

    Hussmann Doors

    thanks gentlemen for your replies.
    yes humidity levels are to high and the frame heaters are not pulsed.(74 and 55 percent factory)
    Hussmann bridgeton, Robert Harold agrees that dehumidification is...
  10. Replies
    6
    Views
    1,124

    Gentlemen, can anyone share any of there...

    Gentlemen,
    can anyone share any of there experiences with the innovator doors and there performance.
    my technician was in a albertsons yesterday and noticed doors sweating on entire line up.
    store...
  11. I take it this is a Surge reciever. Hill for...

    I take it this is a Surge reciever.

    Hill for 25 plus years designed the Atmos systems.
    They Had three designes.
    THEY USED DPR Regulators for 2 Generations and then they went electronic( optic...
  12. Replies
    12
    Views
    1,125

    Hill- Phoenix screw rack.

    Thanks Ned,

    for all your Knowledge and experience.


    GM-1978
  13. Replies
    12
    Views
    1,125

    Thanks Ned.

    Ned,

    thanks for your reply.
    Yes this would be a scheduled PM for this RACK.
    This is a New customer and the rack is 3 years old.
    I just recieved a P.O to perform all the work.
    Field experience...
  14. Replies
    12
    Views
    1,125

    F/U answer for Ned.

    Ned,

    basicly i would appreciate any of your experiences
    and any precautions on these r-507 screw racks.
    experiences with, carlyle, the Cem modules or anything else
    that you can think of to...
  15. Replies
    12
    Views
    1,125

    Hill phoenix screw rack. R-507. carrier scew...

    Hill phoenix screw rack.
    R-507. carrier scew compressors, o6trd and o6tado.
    combo rack, with hot gas defrost, liq subcooled.

    gentlemen,
    any experience on changing the oil on these screw racks...
  16. Replies
    10
    Views
    1,003

    market man.

    my opinion only.

    today with companys like albertsons,kroger and safeway
    that represent 75 percent of a 660 billion dollar industry
    and the the poor souls that bid and accept those losing
    and...
  17. Replies
    8
    Views
    1,751

    5H60 open drive.

    who decided to use Hp-80 on this lo-temp application.
    is there an oil cooler on this compressor and if so is there a bypass sleave in the bearing head.
    IM not there at the job site, but i know one...
  18. Replies
    7
    Views
    1,405

    2 stage refrigeration.

    i apologize for caps lock,
    bare with me please.
    thanks for the replies everybody.
    even working for the factory for 21 years,all compressor rack designs were challenged with this problem.
    in the...
  19. Replies
    18
    Views
    2,797

    TANDEM COMPRESSORS.

    DOESN'T HURT TO HAVE A OIL SEP WITH A OIL RESERVOIR AND FLOATS.I HAVE EXPERIENCED OIL EQUILIZING LINES, JUST QUITE DONT MAKE IT.
    DEPENDING ON YOUR APPLICATION AND THE WAY THE STORE OR WAREHOUSE IS...
  20. Replies
    7
    Views
    1,405

    R-22 TWO STAGE RACK SYSTEM

    HAS ANY BODY EXPERIENCED ON 2 STAGE REFRIGERATION SYSTEMS.
    IT DOES NOT MATTER WHO THE RACK MANUFACTURE IS.
    CARLYLE O6E ON THE LOW STAGE SYSTEMS SEEMS TO BREAK VALVES.

    WITH PRETTY CONSTANT LOAD...
Results 1 to 20 of 20