  1. Thread: weed eater?

    by bm92g7
    Replies
    17
    Views
    3,985

    nyuk nyuk nyuk!

    nyuk nyuk nyuk!
  2. Replies
    11
    Views
    1,663

    I did notice the insulation on the door was loose...

    I did notice the insulation on the door was loose and not fully attached, I spray glued it back on, maybe that is the problem
  3. Replies
    11
    Views
    1,663

    We are going to wait till it gets colder here...

    We are going to wait till it gets colder here before we take more tests on the unit, (it was 75 today). The gas pressure was fine 3.5" as it should be, no restrictions in the tubes and the inducer is...
  4. Replies
    11
    Views
    1,663

    Lennox heat exchanger bad after less than 1yr

    Lennox MN LGC036S2BS1G SN 5606B06672 nat gas rooftop, replaced the heat exchanger less than 1 yr ago when it was found bad on a PM. Came back a week ago to do the PM again for this place, checked...
  5. Replies
    17
    Views
    2,805

    I had a similar problem and turns out that the...

    I had a similar problem and turns out that the board was sending 24v to both sides of the C1 coil. When I would test each side of the coil to ground I would get 24v so it wouldn't pull in obviously....
  6. Thread: Draft issues?

    by bm92g7
    Replies
    7
    Views
    1,199

    Should probably turn the picture huh?

    Should probably turn the picture huh?
  7. Thread: Draft issues?

    by bm92g7
    Replies
    7
    Views
    1,199

    Draft issues?

    I thought this insulation was cut, but no it's definitely melted. Draft issue?
  8. Thread: Hmmmm?

    by bm92g7
    Replies
    18
    Views
    3,207

    ya that's why they cork taped the tee and drilled...

    ya that's why they cork taped the tee and drilled the hole on the other side of the trap, the lady said it wasn't draining right and that the unit wasn't pitched towards the drain... I put a level on...
  9. Thread: Hmmmm?

    by bm92g7
    Replies
    18
    Views
    3,207

    ya it's the condensate drain line, and the cork...

    ya it's the condensate drain line, and the cork tape is covering a copper cap that was put on the stub of copper coming out of the tee
  10. Thread: Hmmmm?

    by bm92g7
    Replies
    18
    Views
    3,207

    Hmmmm?

    What's wrong here?

    (The red box is showing a hole that was drilled into the copper)
  11. Replies
    9
    Views
    2,160

    bring your step stool when you bring your tools...

    bring your step stool when you bring your tools up haha
  12. Replies
    16
    Views
    2,656

    I remember in school them saying you could clean...

    I remember in school them saying you could clean the pump strainer.... not so much here i'm afraid
  13. Replies
    12
    Views
    2,304

    I'm really only interested in peoples feedback on...

    I'm really only interested in peoples feedback on this item, but thanks anyways.
  14. Replies
    12
    Views
    2,304

    Fluke RLD2 HVAC/R Flashlight feedback

    Does anyone have or has used a Fluke RLD2 HVAC/R Flashlight? Just wondering if it works as well as they make it seem at Fluke. How well does it work say on a roof in the middle of the summer when...
  15. Replies
    20
    Views
    3,457

    That was my guess there has to be a relief...

    That was my guess there has to be a relief somewhere on this unit but the air vent is still pretty useless. That expansion tank def needs support, especialy once it fails and fills with water 100%. I...
  16. Replies
    8
    Views
    1,778

    I'm lazy so here ...

    I'm lazy so here

    http://en.wikipedia.org/wiki/Variable_air_volume
  17. Replies
    8
    Views
    1,778

    you're asking what a VAV coil is?

    you're asking what a VAV coil is?
  18. Replies
    8
    Views
    1,778

    we cut a hole in the duct work and vacuumed and...

    we cut a hole in the duct work and vacuumed and cleaned the coil, they don't want to do anything about it as far as prevention, I think they are selling the building.
  19. Replies
    3
    Views
    1,039

    lifetime warranty water heater

    This is in a luxury apt/condo. When you open the door to the left you will see the racking that 2 water source heat pumps sit on. To the right you will see the door jam. Now you don't need to us a...
  20. Replies
    8
    Views
    1,778

    slight lack of air flow

    VAV coil that's attached to internally insulated duct work.... needless to say they had airflow issues.


    :gah:
  21. do you see the wire yet? over? haha! ...

    do you see the wire yet? over?

    haha!


    anyone?
  22. Replies
    2
    Views
    1,298

    Do you see what I see?

    I'm sure we've all had the HD bail us out here and there, saw this and just had to take a picture. Not only is it funny but what a deal!
  23. Replies
    16
    Views
    2,089

    I believe this was a new PM contract and during...

    I believe this was a new PM contract and during the fall PM we found this. It was either the other company or a maint. guy that did this. But we condemned the unit and told them it wasn't coming back...
  24. Replies
    16
    Views
    2,089

    Need better tape

    Probably should of used a stronger tape haha!:oops: