Search:

Type: Posts; User: gypsieking

Search: Search took 0.00 seconds.

  1. Replies
    13
    Views
    1,603

    I passed the manual J. Thanks for all your help.

    I passed the manual J. Thanks for all your help.
  2. Replies
    13
    Views
    1,603

    The exam was tough. I believe all my figures...

    The exam was tough. I believe all my figures where acurate. I got a little rushed the last hour and it looks like a child drew in all the systems on the print but the info was there and done...
  3. Replies
    13
    Views
    1,603

    Thanks for everyone's help. I am feeling more...

    Thanks for everyone's help. I am feeling more confident. I take the exam Wed and should know the result by Friday. I will let you know how I did.
  4. Replies
    13
    Views
    1,603

    Okay. I have just slipped into the darkness...

    Okay. I have just slipped into the darkness again. Let me tell you what I have. I have a winter design temperature difference of 75. A summer design temperature difference of 20. Room Relative...
  5. Replies
    13
    Views
    1,603

    Thanks fellas: I may have a chance at this yet.

    Thanks fellas: I may have a chance at this yet.
  6. Replies
    13
    Views
    1,603

    Delta T: I am not allowed to use anything past...

    Delta T:

    I am not allowed to use anything past 7th edition for this exam manly, I am told, because 7th edition was still long form. To tell the truth I do not even own anything past 7th edition. ...
  7. Replies
    13
    Views
    1,603

    Thanks. You are really helping me out. Let me...

    Thanks. You are really helping me out. Let me run this past you.
    I have a Sensible gain of 17671 Btu (Calculation Procedure D)
    I have a Latent gain of 6044 Btu (Calculation Procedure D)
    Add...
  8. Replies
    1
    Views
    575

    2006 International Code 801.6 Minimum Size...

    2006 International Code

    801.6 Minimum Size of Chimney or Vent.
    Except as otherwise provided for in this chapter, the size of the chimney or vent serving a single appliance, except engineered...
  9. Replies
    12
    Views
    8,718

    Materials within Plenums shall have a flame...

    Materials within Plenums shall have a flame spread indes of not more then 25 and a smoke-developed index of not more then 50 when tested in accordance with ASTM E 84. 2006 International Code.
  10. Replies
    13
    Views
    1,603

    I Need Manual J help

    I am taking a contractors test and I have to do a Manual J 7th edition. I am getting quicker but I need some help this weekend. When I get to the equipment summery, how do I get the Cooling CFM and...
  11. Replies
    0
    Views
    337

    I need some schooling on Manual J

    I am taking a contractors test and I have to do a Manual J 7th edition. I am getting quicker but I need some help this weekend. When I get to the equipment summery, how do I get the Cooling CFM and...
Results 1 to 11 of 11
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event