  1. I`ve used this stuff called Hot Damn . It`s red...

    I`ve used this stuff called Hot Damn . It`s red in color and reuseable , it will keep the heat from destroying valves and TXV`s
  2. Replies
    24
    Views
    1,114

    Fedders

    Fedders
  3. Replies
    20
    Views
    853

    IF you are a carpenter Open the wall before the...

    IF you are a carpenter Open the wall before the HVAC people arrive so they can see what they are up against going down and out the side wall should not too hard but must have SEPC`S from manufacture...
  4. Replies
    30
    Views
    3,122

    cap will do ... but shouldn`t it be located...

    cap will do ... but shouldn`t it be located inside the emergancy pan as will so if it did crack the water would be in the pan not the ceiling below.
  5. Replies
    4
    Views
    429

    dirty FS maybe

    dirty FS maybe
  6. New heater ???? just filled the flue trap and...

    New heater ???? just filled the flue trap and 1st. or 2nd time it ran and no real coldness outside ??
  7. Replies
    17
    Views
    2,020

    how many returns does this home have connected to...

    how many returns does this home have connected to the main return duct?
  8. go into promps and set the deadband for heat and...

    go into promps and set the deadband for heat and cool ... dead band may be set for 3-4 degrees below thermostat temp. reading and will not activate until it get to the dead band setting.
  9. Replies
    6
    Views
    430

    back side of floor registers should be keep off...

    back side of floor registers should be keep off outside wall by 6 inches due to vertical blindes at window so air coming out of vent due not blew up blinds and rattle them
  10. Replies
    6
    Views
    430

    floor due 2 heat rises low speed

    floor due 2 heat rises
    low speed
  11. Replies
    18
    Views
    1,485

    remember problems never go away

    remember problems never go away
  12. Replies
    18
    Views
    1,485

    Hold on .... R U saying you left a job with out...

    Hold on .... R U saying you left a job with out checkin both a/c and heat check out? before saying all is complete??

    Check out system operation inducer, pressure switch, HSI and proven flame...
  13. Replies
    44
    Views
    2,522

    go to your township/tax office and ask if there...

    go to your township/tax office and ask if there is a ordnance against having a commerical bussiness in a residence area.
  14. All piping must be equal in size and length. LLS...

    All piping must be equal in size and length.
    LLS must be installed on both units
    Interlock relay for 24v.
    that the way carrier corp. tech told us. if we used 2 AHU and a single Condenser
  15. circular motion and steady pull pressure.

    circular motion and steady pull pressure.
  16. Replies
    7
    Views
    588

    Is the PVC pipe shoved into the pump to far/ 1/2...

    Is the PVC pipe shoved into the pump to far/ 1/2 inch from the top should be good
  17. Replies
    1
    Views
    917

    filter grill or reteurn air plenunm/ or in the...

    filter grill or reteurn air plenunm/ or in the return air air cabinet its self
  18. Replies
    12
    Views
    1,643

    Does the dryer vent run through the attic and...

    Does the dryer vent run through the attic and terminate throught the roof?
  19. Replies
    14
    Views
    30,078

    Burnt plastic smell still there? Upflow heater...

    Burnt plastic smell still there? Upflow heater with a cooling coil on top??? Blower motor at on point may have stopped working and high temp. rise was to excessive on the coil pan and could have...
  20. Replies
    5
    Views
    1,004

    late 50`s early 60`s not to sure sisters house...

    late 50`s early 60`s not to sure sisters house 10 yrs. ago we replaced the heater nothing wrong with it still runs in the garage today
  21. Replies
    5
    Views
    1,004

    GM DELCO-HEAT Conditionair Product of...

    GM DELCO-HEAT
    Conditionair
    Product of General Motors
  22. have them check the screen on the...

    have them check the screen on the PressureReducingValve if you have well/hard or (small particulates) water the screen will/can get clogged and can not fill the boiler and if you don`t have a LWC you...
  23. Replies
    2
    Views
    838

    Direct Payne 15SEER is a heatpump and should be...

    Direct Payne 15SEER is a heatpump and should be matched up with the correct fan coil and the fancoil will aready have a factory installed TXV. PH15NRO30 ( PH) = heatpump PA16NRO30 ( PA) - stright...
  24. Replies
    8
    Views
    990

    make a fitting if possible to go with a...

    make a fitting if possible to go with a horizontal coil if you don`t have the higth in the closet but you have the length
  25. Replies
    2
    Views
    422

    I can be done with a fan timer control board and...

    I can be done with a fan timer control board and sensor . but the installer needs to know low voltage control wiring. i`v done 1 with the edge thermostat.