Type: Posts; User: hsc tech 1

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    1,006

    SWUD A3 DIP

    maxster,you told me "any other ucm questions don't hesitate ask away.i was the "swud king" of NYC back in the late 80s.
    Can I e-mail you ? my e-mail is elvisjim @ yahoo.com.I have never cleaned, the...
  2. Replies
    25
    Views
    8,385

    black book

    Total agree.I remember in the old days, when a Trane rep.drove up on the job. the feeling of pride ,a willing to help. Here is the man. All questions was answered today,
    In todays bid war, If I was...
  3. Replies
    9
    Views
    1,006

    SWUD A3 DIP

    Maxster, ding ding ding, yes techs, we have winner. The award for best competition in the SWUD catagory goes to MR. Maxster of NYC. A dinner at the local pub, follow by girls dressed in the new CPU 2...
  4. Replies
    9
    Views
    1,006

    A3 dip sw

    Maxster, Thank you,Thank you, Just what I needed.
    sw1 dip 5,need you to help me out. On means what?
    I'm slowly remebering the rest. Been along time ago I worked for trane.I miss getting to see the...
  5. Replies
    9
    Views
    1,006

    Calling all Trane tech. Does anyone have the dip...

    Calling all Trane tech. Does anyone have the dip switch settings for A3 Configuration. Sw1,SW2,SW3 and what they are for? The IOM does not tell ,only factor set, thats great if someone has not...
  6. Replies
    10
    Views
    984

    Cut the COST,sell as low as you can , fatboy is...

    Cut the COST,sell as low as you can , fatboy is 100 percent right on. I got seven rooftops has two stage cooling, six condensor fans, one fan on vfd, other five fans on ambient. If first stage...
  7. Thread: R410A

    by hsc tech 1
    Replies
    17
    Views
    3,646

    The only problem I have is , here in Tn. Trane...

    The only problem I have is , here in Tn. Trane gives the classes. Carrier the same class. You have to take every class for every manufactor.Same gas , Why is that?
  8. Replies
    10
    Views
    984

    agrv, I don't understand your question. I prefer...

    agrv, I don't understand your question. I prefer the pressure type, the sensor type is ok if it is mounted right.
  9. Replies
    29
    Views
    3,157

    chiller.o degree superheat

    mkitrtfst,0 degree superheat? I was thinking.4 to6, have to get the old book out.Superheat suould be set in the micro.After the parimeters are set, the micro takes over.TEVs are control by...
  10. Replies
    16
    Views
    1,917

    anyone want to bet the condensor coil looks like this or worse ?

    Hey Cynic, thats looks like Trane.
  11. Chilled Water

    Dukrster, First of all, you said you have an old chiller.
    What was the original gas, has the TXVs been changed out, why has the controls been jumped out? Is the control on leaving water side or...
  12. Replies
    7
    Views
    1,675

    roc service, Man THANK YOU. know exactly what I'm...

    roc service, Man THANK YOU. know exactly what I'm talking about.I was getting frustrated with myself , not being able to communicate with other techs.You solved the problem. You the man.
  13. Replies
    7
    Views
    1,675

    Cynic, thank you for the respond, the 1-3/8"cap...

    Cynic, thank you for the respond, the 1-3/8"cap and stub is all one piece. I need to take a picture to show what I'm trying to explain. Sorry for the confusion.
  14. Replies
    7
    Views
    1,675

    Airworx, sorry for not being clear, new install....

    Airworx, sorry for not being clear, new install. the suction line from the service valve is only 1.5 inches long or stub. The end is rounded, the IOM calls it a disc, drill a hole in the end and...
  15. Replies
    7
    Views
    1,675

    Had to install 2 York 15 ton split condensor...

    Had to install 2 York 15 ton split condensor units each having two circuits. Simple right?
    Each suction service valve has a 1-3/8 copper stub tubing od. about 1.5 inches long with a rounded end all...
  16. Replies
    29
    Views
    3,157

    txtraneman, is right on, check the condenser fans...

    txtraneman, is right on, check the condenser fans .
    If the fans do not come on ,time versus saturate temp in the micro, it may be going into panic mode, causing all condensor fans to run....
  17. Replies
    29
    Views
    3,157

    mkit, you will do fine, we all have been there...

    mkit, you will do fine, we all have been there before, right guys ???
  18. Replies
    29
    Views
    3,157

    Best advice I can give On RTAA, don't trust the...

    Best advice I can give On RTAA, don't trust the micro on pressure or temp reading ,when you have a trip. Check the temp and pressure yourself. Had the same broblem. Oil diff.
    control was all that...
  19. Thread: vav

    by hsc tech 1
    Replies
    5
    Views
    1,910

    Any Trane support? Last time I used eware on...

    Any Trane support? Last time I used eware on replacement of vav board.New board needed, was told to use Rover,Only have 6 vav boxes on an old Tracer system. Is there a possibility of a shareware...
Results 1 to 19 of 19