    JCI FX Customer Training Manual ???

    Anyone have a link to a JCI FX customer training manual? One you would use for a job closeout training session that is not too elaborate but enough information to cover topics such as system...
  2. Replies
    3
    Views
    2,020

    MODBUS RS-485 cable???

    I am working on a project which requires MODBUS integration to Automatic Transfer Switches. I can't recall the ATS manufacturer but we were told that they recommend we use one of the following...
  3. Replies
    7
    Views
    1,175

    I called Belimo today and the guy told me they do...

    I called Belimo today and the guy told me they do not have high temp valves and that their actuators are rated to 122F. Any idea on the model#. I'll double check their website. Dave, I'll look into...
  4. Replies
    7
    Views
    1,175

    high temp electronic valve/actuators???

    We have a customer who wants to convert all of his existing pneumatically controlled 3/4", 2-way steam valves in radiators to electronic for BAS control. The existing valves are mounted inside the...
  5. Replies
    8
    Views
    1,486

    Automated Logic Bacnet MS/TP vs Arcnet

    I need to tie in a JACE to existing ALC "SE" and "ZN" controllers via BACnet MS/TP but it appears the field bus is Arcnet. The literature for the controllers read Arcnet or BACnet MS/TP...
  6. MM82, Thanks a lot for the info. I'll take a...

    MM82,
    Thanks a lot for the info. I'll take a look at it today. Based on your expertise, would this driver be the best option for what I'm looking for and will it bring in all of the controllers...
  7. Matrix, I knew someone would ask me this but I'd...

    Matrix,
    I knew someone would ask me this but I'd be glad to answer. We actually performed a project there a while ago with an NAE. We also have NAEs at their other facilities so we will be...
  8. Barber-Coleman Network 8000 Integration??

    Hello,
    I'm looking to help out a good customer of ours by integrating to an existing Barber-Coleman Network 8000 System using a Johnson Controls System. Although we currently have a NAE onsite, it...
  9. How do you apply for a Pro membership and what...

    How do you apply for a Pro membership and what are the benefits? Thanks.
  10. Thanks. I figured you had extended memory. I'm...

    Thanks. I figured you had extended memory. I'm going with extra memory anyway to accommodate future controllers.

    Question: If I had a job without the FX server and it had (3) FX Supervisory...
  11. Mechdorn, Thanks. This is the type of...

    Mechdorn,

    Thanks. This is the type of information I was looking for. I too will be implementing a FX Server so is it safe to use 1600 pts per trunk as a max guidline?

    At this time, we are...
  12. CCIKelly, My profile has been updated, thanks....

    CCIKelly,

    My profile has been updated, thanks. I will look into a pro membership but if you could provide any advice in this thread, it would be appreciated.

    Thanks. :cheers:
  13. We are an ABCS but currently have access to both...

    We are an ABCS but currently have access to both FX & Metasys Lines. I'm looking at around 450-500 FEC field controllers (400 of which are FEC VMA VAV Controllers and the others for AHUs and Hot...
  14. This is a real job. The FECs will be controlling...

    This is a real job. The FECs will be controlling AHUs, VAVs and Hot Water System equipment and will communicate to the FX Supervisory Controllers via BACnet MS/TP.

    I'm figuring it will be best...
  15. Replies
    4
    Views
    800

    Ottoreload, I'm working on a project where I...

    Ottoreload,

    I'm working on a project where I have to run my own Ethernet network between building controllers.....one being in a remote building (approx 500 feet between buildings with no critical...
  16. Meaning what.....bus length or cable type? ...

    Meaning what.....bus length or cable type? FYI...the bus cable will be 22awg, 3-conductor shielded for BACnet communication over the FC bus.
  17. By the way, the Johnson Field Controllers coming...

    By the way, the Johnson Field Controllers coming off of the FX Supervisory Controllers will be FEC BACnet Controllers.

    Thanks.
  18. Johnson FX20/60/70 Capacities + Integration

    Is there anyone who has extensive experience with these controllers? I was always curious to know how many controllers can be handled by each version of the FX Supervisory Controllers....although...
  19. Replies
    6
    Views
    2,816

    It would be appreciated if you could also send me...

    It would be appreciated if you could also send me manuals on this system. I am dealing with a site that has 4-GCM's, GCS's, and MicroZone I & II Controllers.

    My email is Email Address's Belong in...
  20. Replies
    9
    Views
    1,827

    JCI FX vs LX LON Controllers

    Anybody have any experience with any of these JCI LON Controllers (FX vs LX). Please list pros & cons if possible.

    We use the FX Controllers a lot but with N2 and BACnet cards. We have never used...
  21. Replies
    2
    Views
    665

    Trane/LON Experts

    Hey guys,

    I'm working on a job where I'm looking at installing (160+) JCI LX Lon-based controllers or TEC Lon-based communicating thermostats under 2-new Trane BCU LonTalk comm5 links for fan coil...
  22. Replies
    4
    Views
    1,094

    Great information and suggestions. We are doing...

    Great information and suggestions. We are doing the programming and do have extremely seasoned programmers although it will be a learning curve because of our lack of immediate knowledge of Trane's...
  23. Replies
    4
    Views
    1,094

    Thanks Scrooloose, Option#1) What do you mean...

    Thanks Scrooloose,

    Option#1) What do you mean by SCC profile? Is there anyway to determine this by way of literature? Based on your suggestions, it appears option#1 would definitely be the best...
  24. Replies
    4
    Views
    1,094

    Trane Summit Bacnet interface to JCI

    Gentlemen,

    I'm working on a project that requires an existing campus multi-site Trane Summit System to integrate to a new building's JCI system. I received help from a few people on here...
  25. Replies
    17
    Views
    2,554

    Please provide to me as well if available. ...

    Please provide to me as well if available.

    Thanks a lot!!!