Search:

Type: Posts; User: m8j4c

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    16
    Views
    1,411

    Any fire dampers closed that aren't supposed to...

    Any fire dampers closed that aren't supposed to be?
  2. Replies
    16
    Views
    1,411

    Did the noise stop when you opened the door to...

    Did the noise stop when you opened the door to the fan belt section?
  3. Thread: time on break

    by m8j4c
    Replies
    5
    Views
    855

    You can probably program a cooling minimum run...

    You can probably program a cooling minimum run time and/or compressor cycles per hour to control that in your t-stat.
  4. Replies
    16
    Views
    903

    If you're changing out the valve I would sawzall...

    If you're changing out the valve I would sawzall the top 3 lines at the bad reversing valve body so that you have the female side of the reversing valve connections still there then in unsweat the...
  5. Replies
    6
    Views
    536

    Of course you can top it off. Why would you have...

    Of course you can top it off. Why would you have to recover it all?
  6. Replies
    27
    Views
    1,428

    Why don't you just measure your actual superheat...

    Why don't you just measure your actual superheat and adjust it to dial it in?
  7. Thread: gantry

    by m8j4c
    Replies
    9
    Views
    1,069

    Chopper time!

    Chopper time!
  8. Depends who you are doing your apprenticeship...

    Depends who you are doing your apprenticeship with. I know in my union guys who had experience could take a placement test and if you tested really well they would knock off a year or 2 off your...
  9. Is there pressure taps on both sides of the...

    Is there pressure taps on both sides of the condensor loop to check pressure drop? I cant remember with crac units... If there is theres usually some reference chart to see if your flow through the...
  10. Replies
    6
    Views
    526

    Not to mention, a compressor that old could very...

    Not to mention, a compressor that old could very well have some damage to the valves or pistons which isnt allowing it to "pump" as effectively. Which would be why it runs all day and only works...
  11. Referteacher got it. Just take your time and...

    Referteacher got it. Just take your time and shake the foam down.
  12. Replies
    20
    Views
    2,066

    Fan cycle controller. Or whatever you are more...

    Fan cycle controller. Or whatever you are more comfortable with.
  13. Replies
    5
    Views
    887

    Check the Oil cooler.. Maybe a failing bearing.

    Check the Oil cooler.. Maybe a failing bearing.
  14. Thread: R11

    by m8j4c
    Replies
    1
    Views
    460

    Yeah, find the nearest meth dealer and make a...

    Yeah, find the nearest meth dealer and make a fortune off of him! Its funny cause its true...
  15. Thread: epa cert

    by m8j4c
    Replies
    3
    Views
    285

    Go to a local refrigeration supply parts house....

    Go to a local refrigeration supply parts house. They usually offer the tests. Comes with a book to study, usually around $60-$75.
  16. Replies
    10
    Views
    902

    yeah that was crazy.. Still trying to get a hold...

    yeah that was crazy.. Still trying to get a hold of some cousins who live there myself...
  17. Thread: Green slime?

    by m8j4c
    Replies
    15
    Views
    1,302

    This is crazy.. I havent seen this yet and...

    This is crazy.. I havent seen this yet and thought it only happens on chillers with a leak in the evap where the water pressure was somewhat high.
  18. Replies
    5
    Views
    504

    Stick with the whole house fan idea using your...

    Stick with the whole house fan idea using your access hole. Play around with only opening a few room windows and your main issue with it not being able to move enough air maybe due to you not having...
  19. Replies
    11
    Views
    1,760

    Diceman, Why would a coil keep leaking if it has...

    Diceman, Why would a coil keep leaking if it has already been fixed?
  20. Thread: Capacitor tester

    by m8j4c
    Replies
    9
    Views
    896

    Any cheap digital meter that also reads...

    Any cheap digital meter that also reads microfarads will work. If its something you are gonna use alot, dont go cheap.
  21. Replies
    8
    Views
    1,071

    Try to get them the comissioning report if you...

    Try to get them the comissioning report if you can, thats all you can do. I used to work for Carrier and did a lot of warranty work. If you bug them enough they will take care of it for you. Beleive...
  22. Thread: Getting started

    by m8j4c
    Replies
    4
    Views
    475

    Somebody is breaking you in pretty quickly. Not...

    Somebody is breaking you in pretty quickly. Not bad.
  23. Thread: furnace problems

    by m8j4c
    Replies
    2
    Views
    431

    Lets leave diagnostics to an on site tech, please...

    Lets leave diagnostics to an on site tech, please read site rules, thank you.
  24. Thread: Kansas City Area

    by m8j4c
    Replies
    10
    Views
    759

    Steward, what do you mean "eq. in town"???

    Steward, what do you mean "eq. in town"???
  25. Thread: Kansas City Area

    by m8j4c
    Replies
    10
    Views
    759

    Freonrick, Who do you work for now? What was it...

    Freonrick, Who do you work for now?
    What was it about Carrier's management that made you leave?
Results 1 to 25 of 32
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event