  1. Replies
    2
    Views
    193

    No the compressor is running . And pulling amps ....

    No the compressor is running . And pulling amps . I'm thinking its a plugged outdoor coil orifice . Making sure about warranty information first before I start taking out redrigerant tho
  2. Replies
    2
    Views
    193

    Magik-pak unit problems

    Hello guys. A week ago I ran into a magic pack unit in a outdoor closet . That is about 3 months old . Switches into heatpump and pressures won't move . But maybe 1 or two psi . Amped out everything...
  3. Replies
    3
    Views
    336

    Powered Humidifier

    Ok I was reading some posts before this and I just have to be cleared up on this subject. Is it possible to put a powered humidifier on the return air duct. If so great!. If not, then how come. I...
  4. Thread: SAW DUST!!!

    by CHEAPRHVAC
    Replies
    5
    Views
    483

    SAW DUST!!!

    ok guys, So my friends dad owns a cabinet business. In his shop he has two units an old one and a new one. The old one he keeps having problems with because the dust goes through the fiberglass...
  5. Thread: SAW DUST!!

    by CHEAPRHVAC
    Replies
    2
    Views
    562

    SAW DUST!!

    ok guys, So my friends dad owns a cabinet business. In his shop he has two units an old one and a new one. The old one he keeps having problems with because the dust goes through the fiberglass...
  6. Replies
    11
    Views
    887

    Hot water vs Cold water Humidifiers

    Alright guys might be a stupid question, but here it goes. Can I get some answers as to the differences of both Hot water vs Cold water Humidifiers. Example applications, where locations differences...
  7. Replies
    3
    Views
    807

    Ok thank you for the reply.

    Ok thank you for the reply.
  8. Replies
    33
    Views
    2,246

    Voltage is somewhere around 90.

    Voltage is somewhere around 90.
  9. Replies
    4
    Views
    438

    I would check to see if you Programmed the...

    I would check to see if you Programmed the Thermostat Correctly. Would be my first guess.
  10. Replies
    16
    Views
    3,455

    May I ask why you didn't set the condensing unit...

    May I ask why you didn't set the condensing unit lineset toward the wall so it wasn't so long and didn't have to put the bends on it? Just wondering, not saying you were wrong.
  11. Replies
    7
    Views
    626

    Ok that would make sense. And good job on find....

    Ok that would make sense. And good job on find. GL in the future
  12. Replies
    7
    Views
    626

    Ok I checked your profile . It's good .. Where is...

    Ok I checked your profile . It's good .. Where is it in the order of radiators from start to return ? And Is it the only inoperable radiator ?


    Sent from my iPhone using Tapatalk
  13. Replies
    7
    Views
    626

    I doubt it if the radiator heated before . And...

    I doubt it if the radiator heated before . And are u tech or home owner ?


    Sent from my iPhone using Tapatalk
  14. Thread: i'm 98%

    by CHEAPRHVAC
    Replies
    157
    Views
    28,350

    2% here. I wonder why anyone would think red...

    2% here. I wonder why anyone would think red hammer. Unless they had a red hammer. In which case how many techs actually have a red hammer?
  15. Appion G5 Twin, and Appion tez8. Pricey, but...

    Appion G5 Twin, and Appion tez8. Pricey, but worth it. You can check out my post on when I got a new one, and see mine. Was pricey, but definitely worth it.
  16. Thread: Seriously?

    by CHEAPRHVAC
    Replies
    1
    Views
    1,735

    Seriously?

    459871459881
    Ok I know u guys are thinking .. Sure I've seen this before .. But come to find out the higher one was hooked to the intake. You cant tell it but the longer one is tilted at like a 75...
  17. Replies
    7
    Views
    626

    Have you bled the radiators?

    Have you bled the radiators?
  18. Replies
    18
    Views
    1,488

    Check for continuity from low pressure switch...

    Check for continuity from low pressure switch leads to ground. I had one the other day ground out to the copper inside the low pressure switch.

    - - - Updated - - -

    I also recommend getting a...
  19. Replies
    36
    Views
    2,314

    Have you amped the Compressor when running, and...

    Have you amped the Compressor when running, and checked the ohms of the windings?
  20. Replies
    13
    Views
    1,019

    Very true. I agree with that, and thanks for the...

    Very true. I agree with that, and thanks for the advice. But the heatpump seems to work fine at 15degreese and above. Its just this cold spells we have been having at 10 and below.
  21. What is the manometer pressure ?

    What is the manometer pressure ?
  22. I don't know about your original question. I...

    I don't know about your original question. I don't think there is, but were your spark tips placed correctly in front of the nozzle, and distanced from each other with the other units you replaced...
  23. Replies
    18
    Views
    1,226

    I know it is highly unlikely, but is it possibly...

    I know it is highly unlikely, but is it possibly you could have a clogged heat exchanger? Causing the flames in one tube to roll back
  24. Replies
    13
    Views
    1,019

    Thanks for all of your responses. I agree with...

    Thanks for all of your responses. I agree with most of you on the heatpump. My question was pretty much if you guys think that is a good split. I would switch to emergency heat and let that go, but...
  25. Replies
    13
    Views
    1,019

    heatpump w/ strip backup

    Hey guys . I checked a lot of heatpumps today. Different things wrong, but when I get them to where they should be around for the conditions today I only got like a 10degree split. It was 7 degrees...
  26. Replies
    17
    Views
    1,231

    456991 Here it is guys thanks for all of your...

    456991
    Here it is guys thanks for all of your advice . Ended up going with appion. Got it on eBay for $700 new . Thought that was a really good price . Let me know if u think other wise . Can't wait...
  27. Thread: Txv

    by CHEAPRHVAC
    Replies
    5
    Views
    501

    Are we talking about a Heatpump, and if so which...

    Are we talking about a Heatpump, and if so which txv are you referring too. The indoor or outdoor txv?
  28. Replies
    3
    Views
    807

    Combustible Gas Detector

    Recently I Posted that I was in the market for a new Carbon monoxide detector. I got some reviews back recommending I get a combustion analyzer instead. My question I guess is what makes yours...
  29. Darnit! I meant carbon monoxide. I apologize!

    Darnit! I meant carbon monoxide. I apologize!
  30. Ill check and see how to do that pro membership...

    Ill check and see how to do that pro membership thing. I don't pretend to know a lot. If it seems there is something I am totally missing about what we are talking about in cracked heat exchangers...
  31. Well I guess your right. but I don't use it to...

    Well I guess your right. but I don't use it to completely diagnose a problem. I Normally use it to just check and make sure I don't have a crack in my heat exchanger.
  32. Replies
    3
    Views
    340

    What is model number?

    What is model number?
  33. New Carbon Monoxide Detector Recommendation

    I am in the process of getting another carbon monoxide detector. We have been using the UEI CO detector, and that seems to do the job well. I am looking for one that I can carry with me most of the...
  34. OK makes so much sense. Thank you so much. Guess...

    OK makes so much sense. Thank you so much. Guess that's one of those things ill remember the rest of my life when I run into a situation like that. Hope this post will help someone else out in the...
  35. Thanks for the quick response, But I'm not sure I...

    Thanks for the quick response, But I'm not sure I understand what you mean in your post. Are you saying the coil is fine, but its also possibly touching part of the metal bracket that screws to the...
  36. Replies
    9
    Views
    409

    Yes for sure give us more info on what you are...

    Yes for sure give us more info on what you are producing, and I might order some for my business. Always willing to help a fellow brother.
  37. Replies
    1
    Views
    608

    Carbon Monoxide Detector

    I am in the process of getting another carbon monoxide detector. We have been using the UEI CO detector, and that seems to do the job well. I am looking for one that I can carry with me most of the...
  38. Confusing situation with Compressor Contactor

    Today I went to a call for a no heat. Arrived and it was a heat pump. Long story short the contactor caused the fuse to blow every time when the t-stat called for heating. I isolated it to the...
  39. Replies
    9
    Views
    875

    NU-22b Replacement for R-22

    We used to use this refrigerant when R-22 skyrocketed in price. Ofcourse we didn't use as drop in, but we used as replacement for new compressors and such. Now that prices for R-22 have gone down I...
  40. Replies
    3
    Views
    679

    Thank you so much. Just ordered. Will be using...

    Thank you so much. Just ordered. Will be using this website more. Thanks again
  41. Replies
    3
    Views
    679

    Desa Fireplace Thermocouple

    Hello I was working on a Desa vc36nh fireplace and the thermocouple is bad. So I tried ordering just the thermocouple from the only place I could find that dealt with desa fireplaces. The salesman...
  42. Replies
    17
    Views
    1,231

    I appreciate your opinions, but ive got to say...

    I appreciate your opinions, but ive got to say qwerty that every just better product that I have used or have seen other techs buy have all been junk. from hoses to vacuum pumps. Any other...
  43. Replies
    17
    Views
    1,231

    VACUUM PUMP And CHARGING SCALE

    Ok so it is time for new vacuum pump and charging scale. I need recommendations. I don't want cheap crap either. I don't mind paying more for something that is going to work well and last me a long...
  44. Sticky: Hello guys. My name is Joshua Martin. I started...

    Hello guys. My name is Joshua Martin. I started this field slowly while growing up since my dad was a HVACR service tech. I graduated high school and went to Terra State College for their nine month...
  45. Replies
    5
    Views
    593

    Checking a heatpump

    Ok I know I might get some hassle for not knowing this, but I have even asked some of the techs at the company I used to work for and I got varied answers.
    Lets say you go to do a service check and...
  46. Replies
    23
    Views
    1,464

    As a partially new tech, I understand not knowing...

    As a partially new tech, I understand not knowing some things right off the bat. And no worries, I wont give u hassle for not knowing. Like kls-ccc said you should have a minimum of 5 wires. Yes I...
  47. thanks for all your responses. I plan to go back...

    thanks for all your responses. I plan to go back to the tenants place again on Monday. Where I will then try and check all the stuff you guys have suggested. Thanks again and I will post my...
  48. I didn't make a lot of checks. it was late and i...

    I didn't make a lot of checks. it was late and i told switched them to emergency heat and told them i would be back in the morning. But from what i did find out. i just cant understand why my...
  49. Out door temp was 19degrees. indoor about 68. I...

    Out door temp was 19degrees. indoor about 68. I didn't check exact temp of hot gas line but it was probably about 75 to 85degrees. not enough to keep up with the apartment temp until aux heat came on
  50. Heatpump wont change pressures with additional r-22

    Hello. I was working on a heatpump tonight and it seemed low, so I started to add charge to it and the pressures would not leave 45 suct and like 130 head, even after 3# additional r-22 anyone know...