Search:

Type: Posts; User: lzenglish

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    1,014

    OK, time for some details! What size is your...

    OK, time for some details! What size is your room? Do you have a house cooling return air space, between the ceiling,and the roof? Now this is just shooting from the hip. without knowing those...
  2. Replies
    9
    Views
    1,014

    You have a What, in Who? Lol Just kidding! But...

    You have a What, in Who?
    Lol Just kidding! But you do know this went bye bye long ago! BUT, as Building Engineers, we aim to please, right?
    The only thing you can do is install a dedicated, well...
  3. Replies
    8
    Views
    1,004

    Is this it, a commercial for sporlians web site?

    Is this it, a commercial for sporlians web site?
  4. Replies
    13
    Views
    2,124

    While to other two members try to determine the...

    While to other two members try to determine the correct unit name, let me give you a little overview of what you should be trying to accomplish. The idea behind the ECU, CRU, or CRAC units is to...
  5. Replies
    13
    Views
    2,124

    The correct term is "ECU", or Environmental...

    The correct term is "ECU", or Environmental Control Unit"! I have most all the manuals for the past 30 years, but they are all packed away deep inside my storage unit at this time. I would suggest...
  6. Replies
    16
    Views
    1,529

    Thanks, that is Funny! Wayne

    Thanks, that is Funny!

    Wayne
  7. Replies
    16
    Views
    1,529

    You "feng" Guys Are just the Funniest of the...

    You "feng" Guys Are just the Funniest of the Funny! ha, ha, ha, x 100!!! By the way, what, or who is "feng" ? Sorry i'm not familliar with it, him, or her?

    Thanks,

    Wayne
  8. Replies
    16
    Views
    1,529

    Join RSES, buy their SAM's manual, attend their...

    Join RSES, buy their SAM's manual, attend their meetings, and go to their Seminars offered in you neck of the woods.

    Wayne
  9. Replies
    11
    Views
    903

    Yea, I'm always sorry when I attempt to help out...

    Yea, I'm always sorry when I attempt to help out a person, for what ever reason, that just does not seem to care, by Not responding to our questions.


    Wayne
  10. Replies
    11
    Views
    903

    Yes, Many! What exactly are you dealing with, as...

    Yes, Many! What exactly are you dealing with, as far as DX, Evap. Unit, etc., and it's specs? Your best friend on these experiments are turning vanes, but that is only my first thought, until you...
  11. Replies
    16
    Views
    2,127

    You did good! Did you take an oil sample for an...

    You did good! Did you take an oil sample for an acid test? Did you find the cause of the restriction in the liquid line drier? If it was just the compressor winding varnish breakdown, and or...
  12. Replies
    7
    Views
    1,334

    "AUDELS REFRIGERATION and AIR CONDITIONING GUIDE"...

    "AUDELS REFRIGERATION and AIR CONDITIONING GUIDE" Copyright 1944 thru 1959, page 235.

    Wayne
  13. Replies
    16
    Views
    2,127

    [QUOTE=monkeyspanners;15608151]What size and type...

    [QUOTE=monkeyspanners;15608151]What size and type of system is it? Most likely its the felt pad in the drier that is blocked. I've had a few systems that kept blocking up driers and i changed them to...
  14. Replies
    11
    Views
    1,018

    When it comes to Temperature/Humidity Meters,...

    When it comes to Temperature/Humidity Meters, YES, "Digital"! When it comes to Sevice Gages, it is over the top for me. I have never owned a set, but it seems to me, you would be tied to charged...
  15. Replies
    16
    Views
    2,127

    I don't know if it is needed, but I would...

    I don't know if it is needed, but I would certainly install one as long as you have the system opened up! Also, be sure to take an oil sample while you are in there as well!

    Wayne
  16. Replies
    7
    Views
    1,334

    Ok, after dusting off some of my old refer book...

    Ok, after dusting off some of my old refer book collection, I found your GE circuit. What you have is common for other domestic units of the time period. Basically, what looks like a manifold, is...
  17. Replies
    7
    Views
    1,334

    That is Great, Glad you got it going! But, as a...

    That is Great, Glad you got it going! But, as a fellow A/C guy, you know i need to look into this, and find out just what the deal is here! The lines wrapped around have to be your evaporator. Did...
  18. Replies
    7
    Views
    1,334

    What are the specifics to your refer, such as...

    What are the specifics to your refer, such as brand name, and model # ? I have worked on pleanty of the older ones, but am not familiar with this dual charge circuit manifold you speak of. Most old...
  19. Replies
    9
    Views
    1,620

    OK, first off, I do not see AOP in red on this...

    OK, first off, I do not see AOP in red on this one, so I hope I can offer you an answer. What takes place inside a Compressor, be it a Reciprocating, Scroll, or Centrifical, is Heat, and Friction...
  20. Replies
    16
    Views
    1,868

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  21. This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  22. This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  23. Replies
    14
    Views
    1,543

    It sounds to me your cond. fan motor is...

    It sounds to me your cond. fan motor is "windmilling"! This can happen if and when the cond. unit is off, and the wind blows the cond. fan blade in the reverse direction. If it gets up to around 70%...
  24. Replies
    54
    Views
    4,058

    Poll: Want a Career in the HVAC/R field, make 60k to...

    Want a Career in the HVAC/R field, make 60k to 90k a year, without all the running, and have a home life to boot? Become a Stationary Engineer! I was in Your shoes many years ago, and made the...
  25. Replies
    2
    Views
    507

    It looks like a well rounded course to me. The...

    It looks like a well rounded course to me. The heating and ventilation are incorporated in the HVAC/R term. As far as your entry exam, i would expect the usual math like, adding, subtraction,...
  26. Replies
    2
    Views
    425

    Hello Rod: I'm in NorCal myself, and was...

    Hello Rod: I'm in NorCal myself, and was wondering what school you attended, if it is not too personal? I Graduated from M.E.T. in SacTown myself.

    Best of Luck,

    Wayne
  27. Replies
    17
    Views
    1,762

    Perhaps you should act more like a professional...

    Perhaps you should act more like a professional moderator, instead of a comedian? I see you are an RSES member, and 37 years old? I joined RSES when you were around 7 years old, and i assure you, I...
  28. Replies
    17
    Views
    1,762

    Yea, I think that ship has sailed for the hard...

    Yea, I think that ship has sailed for the hard knock responders! They are the best, and "F" the rest, Just ask anyone of them! I did not realize there were this many insecure children on the forum,...
  29. Replies
    17
    Views
    1,762

    This is the one i attended in the 1970's. The...

    This is the one i attended in the 1970's. The founder, and all of my original instructors are gone, but the classes look the same, with a few additions. If you are mechanically inclined, and get...
  30. Replies
    14
    Views
    2,412

    Hello: When i started working as a Stationary...

    Hello: When i started working as a Stationary Engineer, after College, I would say about one half of other engineers i met, were ex Navy Boiler Tenders, and or Machinist Mates. As a matter of fact,...
  31. Oxy/Act, from day one in the buisness. I did also...

    Oxy/Act, from day one in the buisness. I did also carry a map gas turbo torch for a back a up. The thing with the little M/C kits, is you can weld, cut, and solder or braze on anything, for a limited...
  32. Replies
    6
    Views
    1,860

    Nice Horse Blanket!!!!!!!!! I Would Guess this is...

    Nice Horse Blanket!!!!!!!!! I Would Guess this is a Rental Home, Correct?

    Wayne
  33. Replies
    20
    Views
    5,402

    I worked for The City, the County, and the Feds....

    I worked for The City, the County, and the Feds. The buildings were a mix, but mostly Commercial Office Buildings, with a Central Plant to feed them. When I retired, I was a Senior, which is the same...
  34. Replies
    20
    Views
    5,402

    Primarily is a Big Word when you talk Stationary...

    Primarily is a Big Word when you talk Stationary Engineer, but if I had to put them in order, I would go with H.V.A.C as number 1. You will also need to know about High and Low pressure boilers,...
  35. Replies
    20
    Views
    5,402

    Hello: My advice to you is to take every shop...

    Hello: My advice to you is to take every shop class offered in your High School, and get Mechanically Inclined. Then, find a local H.V.A.C. company that will let you work for them as a helper, for...
  36. Replies
    4
    Views
    1,064

    I copy that! I have bought and sold 3 of these in...

    I copy that! I have bought and sold 3 of these in my 30 plus years in the HVAC buisness, but this one will only leave my box when I die as well, and the little woman throws all my tools in the...
  37. Replies
    4
    Views
    1,064

    Thanks for the Info. I have not checked with...

    Thanks for the Info. I have not checked with allied yet, and will do so. I'm still interested in a "parter" if anyone has one for sale.

    Wayne
  38. Replies
    4
    Views
    1,064

    Annie Model A-12 Analyzer parts

    Hello all. I have had an old Annie Model A-12 Compressor analyzer for years, and need parts. I need the little ohm and amp panel meters. Does anyone know where I can pruchase them, or does anyone...