Search:

Type: Posts; User: can

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    7
    Views
    1,477

    You recovery unit only 1/2hp but the subcooler is...

    You recovery unit only 1/2hp but the subcooler is 15hp?
  2. Replies
    7
    Views
    1,477

    Do you know the hp of your recovery unit?

    Do you know the hp of your recovery unit?
  3. Replies
    7
    Views
    1,477

    I'm not sure, But I saw some out pumpout unit...

    I'm not sure, But I saw some out pumpout unit made by another factory that it have this plate heat. So, I want to know how to sizing it!
  4. Replies
    7
    Views
    1,477

    Suction line heat exchanger

    I have a pumpout unit, it is using a 27,000BTU R-134a refrigeranion compressor to pumpout the refrigerants. Iwant to installa plate type heat exchanger to use the refrigerants come from the chiller...
  5. Thread: 19xl

    by can
    Replies
    6
    Views
    1,698

    We are recommend the customers to retrofit the...

    We are recommend the customers to retrofit the PIC 1 control system to PIC 3 or 32XR control system. Some customer retrofit the chiller to use the VFD too.
  6. Replies
    1
    Views
    1,057

    134a cylinder valve

    Anyone know that where can I buy this 134a cylinder valve or its relief valve?
  7. Thread: 19xl

    by can
    Replies
    6
    Views
    1,698

    The program of the PSIO was lost. You are need to...

    The program of the PSIO was lost. You are need to replace the backup battery and reprogram the PSIO or replace an new one!
  8. Replies
    3
    Views
    981

    Power factor capacitor bank

    Anuone know that how to sizing the power factor cap bank for the compressot?
  9. Replies
    8
    Views
    1,982

    Dear Supertek65, Are you Chinese?

    Dear Supertek65,

    Are you Chinese?
  10. Replies
    8
    Views
    1,982

    Dear Supertek65, Thank you very much! Can Lai

    Dear Supertek65,

    Thank you very much!
    Can Lai
  11. Replies
    8
    Views
    1,982

    Dear Steve, See my profile and direct send...

    Dear Steve,

    See my profile and direct send email to me!

    Regards!

    Can
  12. Replies
    46
    Views
    5,256

    High motor temp will not make the bearing damage...

    High motor temp will not make the bearing damage becase the motoe will damage first. if the bearing temp too high. The chiller will shutdown by the alarm of high bearing temp!
  13. Replies
    46
    Views
    5,256

    Yes surage very let the thrust damage, Somtimes...

    Yes surage very let the thrust damage, Somtimes if filled too much refrigerant also will have the same result!
  14. Replies
    46
    Views
    5,256

    I have not his photos copies, but are you need...

    I have not his photos copies, but are you need any help? Or want the spare parts? Are you need any help? What is the complete model of the chiller and where are you come from?
  15. Replies
    46
    Views
    5,256

    Spanner, What is the problem of your 19XL?

    Spanner,

    What is the problem of your 19XL?
  16. Replies
    4
    Views
    657

    Thank you for yours reply. I have 1 question...

    Thank you for yours reply. I have 1 question more, What type of the compressor can use for? A/C or refrigeration type? Inside the refrigeration type still have the Hi, Med and low temp compressor. I...
  17. Replies
    4
    Views
    657

    PUMPOUT UINT COMPRESSOR

    I want to tailor make a pumpout unit and know that normally all the compressor is using reciprocating type compressor. Anyone know that can use the srcoll type compressor or not. Will it easy to...
  18. Thread: 19XR

    by can
    Replies
    9
    Views
    1,044

    JKD, Are you fixed the problem?

    JKD,

    Are you fixed the problem?
  19. Thread: Micron gauge

    by can
    Replies
    19
    Views
    3,092

    The VG64 normally will lose the vacuum reading...

    The VG64 normally will lose the vacuum reading when shut off the valve. It is not a big problem! When you saw the 1st reading of your machine and record down the reading. You can shut off the valve...
  20. Thread: 19XR

    by can
    Replies
    9
    Views
    1,044

    If it is a PIC2 control system. You can disable...

    If it is a PIC2 control system. You can disable this function at the ISM setup page!
  21. Thread: 19XR

    by can
    Replies
    9
    Views
    1,044

    Your control system should be PIC1, not PIC2 by...

    Your control system should be PIC1, not PIC2 by the system have the PSIO, LID and SMM moulde. Is it the alarm history showed POWER LOST? If yes, the problem is come from the SMM. I can repair it....
  22. Thread: 19XR

    by can
    Replies
    9
    Views
    1,044

    Please advise all the ISM settings!

    Please advise all the ISM settings!
  23. Thread: 19XR

    by can
    Replies
    9
    Views
    1,044

    Please check the guide vane is fully closed or...

    Please check the guide vane is fully closed or not before start up!
  24. Replies
    21
    Views
    2,129

    Dear Supertek65, I'll find your thumb drive at...

    Dear Supertek65,

    I'll find your thumb drive at tomorrow morning. thx!
  25. Replies
    21
    Views
    2,129

    What are you means???

    What are you means???
  26. Thread: 23XL Teardown

    by can
    Replies
    10
    Views
    1,531

    Please let me know your email address.

    Please let me know your email address.
  27. Thread: 23XL Teardown

    by can
    Replies
    10
    Views
    1,531

    I was sent a PDF on before, are you still need it...

    I was sent a PDF on before, are you still need it again?
  28. Replies
    21
    Views
    2,129

    Super65, Is it the manual included how to...

    Super65,

    Is it the manual included how to setup the control and what is operation for the York diffuesr? I really want it! I can let you know our DHL collect feright account number to let you send...
  29. Replies
    21
    Views
    2,129

    Supertek 65, Would you like to email a copy to...

    Supertek 65,

    Would you like to email a copy to me? southeng@biznetvigator.com
  30. Replies
    21
    Views
    2,129

    York YKG w/diffuser O & M

    Anyone can get the York centrifugal chiller w/ diffuser O & M?
  31. Replies
    1
    Views
    700

    19XB and 19XR pumpout with storage tank

    "Carrier" have the 19XB and 19XR pumpout with storage tank. On the top of the tank installed a level gage. We can see how many % of the refrigernat level inside the tank. But anyone know that how can...
  32. Replies
    17
    Views
    1,230

    This is not the first time to tell yours if the...

    This is not the first time to tell yours if the Carrier chiller used the York control system will loss oils. Yours can search my posts!

    Regards!
  33. Thread: Carrier 19XL woes

    by can
    Replies
    15
    Views
    1,389

    The problem should be filled too much refrigerant...

    The problem should be filled too much refrigerant into the chiller. Please see the nameplate on your 19XL chiller. DO NOT fill more than 80% of the fully refrigerant charge show on the nameplate...
  34. Replies
    5
    Views
    1,002

    Dear Frank, I'm very busy on this few months....

    Dear Frank,

    I'm very busy on this few months. Replaced 4 sets of 19XR impeller. Disassembled 2 sets 19XR to 3 section, reassemble them inside the plant room and T & C. Now is modify a 134a 19XL...
  35. Replies
    5
    Views
    1,002

    Normally, we will overhaul the Carrier chiller on...

    Normally, we will overhaul the Carrier chiller on or before every 20,000 hrs.
  36. Replies
    4
    Views
    620

    Thank you very much! I find some supplier now!

    Thank you very much! I find some supplier now!
  37. Replies
    25
    Views
    2,018

    Dear Chiller Mekanik, Would you like to help...

    Dear Chiller Mekanik,

    Would you like to help me to answer this qeustion to Town? I really do not know how to answer him by English!
  38. Replies
    25
    Views
    2,018

    Dear chiller mekanik, I'm well, thanks! I'm...

    Dear chiller mekanik,

    I'm well, thanks! I'm long time no reply any post by I.m very busy and my English is very bad!
  39. Replies
    4
    Views
    620

    the style of Carrier 19 series shims

    Anyone repair the Carrier centrifugal chiller. He should be know a shim pack under the impeller. This shim pack have many pcs. of aluminium sheet (0.0002" per pc.). It is very easy to remove from the...
  40. Replies
    25
    Views
    2,018

    Randy S. is correct. If you are need to restart...

    Randy S. is correct. If you are need to restart the chiller at a short time. You can manual start the oil pump 10-15 every mins. to push out the refrigants from the oils. and re-start the chiller....
  41. Replies
    25
    Views
    2,018

    If the power outage with a long time and the...

    If the power outage with a long time and the water temperature is high. The refrigerant will mix into the oils. After you re-power the control. the refrigerant will come out from the oil by the oil...
  42. Thread: 19XR Oil Heater

    by can
    Replies
    12
    Views
    1,060

    Dear hw chiller man, Than you very much for...

    Dear hw chiller man,

    Than you very much for your trust. Would you like to give me some comments for my post the '19XL replacement bearings'
  43. Replies
    24
    Views
    1,704

    Dear Supertek65, I really is Can. The bearing...

    Dear Supertek65,

    I really is Can. The bearing I recommends that it is really a quality bearing! But no one trust me! I'm working on the Carrier centirfugal carrier begining on 1987 up to now! I...
  44. Replies
    24
    Views
    1,704

    www.chinese.com My English is really not very...

    www.chinese.com

    My English is really not very well. If you want to chart with me. Go this link first www.chinese.com
  45. Thread: 19XR Oil Heater

    by can
    Replies
    12
    Views
    1,060

    hw chiller man, Normally, you are really need...

    hw chiller man,

    Normally, you are really need to open up the compressor to replace the 19XL or 19XR oil heater. But you are need to know how to force the heater by your hand to let it smaller. So,...
  46. Replies
    24
    Views
    1,704

    Mathias, If you can not open the PDF file. I'm...

    Mathias,

    If you can not open the PDF file. I'm attached jpeg files now!
  47. LGtonnagetech, Because the chiller installed...

    LGtonnagetech,

    Because the chiller installed at the 4th floor below round floor. If replace the chiller. many shop need to shop their business when the replacement work is doing. The customer will...
  48. Thank you very much!!!!! You are the...

    Thank you very much!!!!! You are the true!!!!!!!!!!!!!!!!!!
  49. Replies
    24
    Views
    1,704

    If the problem is come from the insurance. I...

    If the problem is come from the insurance. I accept everyone will use the OEM bearings if they buy the insurance for the job. But they can not say my posts or our product is a crap!
  50. If the problem is come from the insurance. I...

    If the problem is come from the insurance. I accept everyone will use the OEM bearings if they buy the insurance for the job. But they can not say my posts or our product is a crap!
Results 1 to 50 of 154