Search:

Type: Posts; User: dukebbb

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    32
    Views
    3,769

    I actually felt closure, at least now i know...

    I actually felt closure, at least now i know where to look. I'll do leak checking later and hopefully the charge was vented. Otherwise its gotta be smth big.

    Yeah i've weighed in a few autos...
  2. Replies
    32
    Views
    3,769

    Ok I did a quicky pressure test before heading...

    Ok

    I did a quicky pressure test before heading to work n it seems my total charge was exhausted. This is the last thing in my mind since it happened over night n there was no issue watsoever...
  3. Replies
    32
    Views
    3,769

    Any auto mechanic in the house?

    First of all, i don't know where to post this so mods, pls move this to wherever it belongs.

    I brought our family gmc acadia to the local dealer for a leaky tire valve, wheel balancing & alignment...
  4. Replies
    4
    Views
    643

    I am definately sure approvals r needed for new...

    I am definately sure approvals r needed for new constructions especially if its gonna be a r-2000 or energuide home. Not sure about retrofit though.
  5. Replies
    4
    Views
    643

    Permits in Ontario

    Had a called from a private client living in King city, north of Vaughan. He wants duct work, gas furnace & a/c for his bungalow. It's already gutted. He wants duct work to be in before any other...
  6. Thread: vacuum oil

    by dukebbb
    Replies
    25
    Views
    1,655

    I concur with u, why waste oil when its still...

    I concur with u, why waste oil when its still good... micron gauge will tell u this.

    While we r on the oil subject, do u guys use pumps' manu oil or some off brand stuffs. We have yj pumps at the...
  7. u wont be able to see the underside of the coil...

    u wont be able to see the underside of the coil cos the 2ndary h/e is in the way.
  8. Replies
    4
    Views
    1,037

    Hav to wait til i get home to get the pics...

    Hav to wait til i get home to get the pics resize.

    Do u guys hav problem typing onscreen keys on mobile phones? Especially with callus thjmbs. I spent more time correxting then typing. If a...
  9. Replies
    4
    Views
    1,037

    Honestly i thought this thread never went thru. ...

    Honestly i thought this thread never went thru. I am using my mobile + opera browser. Had to retype 2 times and never able to get it posted.
  10. Replies
    11
    Views
    2,738

    Is it any worse then seal leak on flare nuts? ...

    Is it any worse then seal leak on flare nuts? the gray/bluish stuff, couldnt see very well thru the led lights. I encountered 2 leaks today, couldnt tight any further cos the crap dried up. so had...
  11. Replies
    4
    Views
    1,037

    walkin cooler smack

    got a call from
  12. Thread: vacuum oil

    by dukebbb
    Replies
    25
    Views
    1,655

    I have yet to experience a water contaminated...

    I have yet to experience a water contaminated system as we deal mostly with rooftops and resi applications. Still, once ur pump cant pull down under 1000 micron u know its timme for an oil change. ...
  13. Thread: vacuum oil

    by dukebbb
    Replies
    25
    Views
    1,655

    vacuum oil

    Guys

    Every training I've been to recommends changing vacuum oil after every job. I only change mine when I am unable to get below 400 micron. I wonder what every body does?

    thanks
  14. Replies
    21
    Views
    4,658

    Got myself a bacharach also. Used mostly on r22...

    Got myself a bacharach also. Used mostly on r22 and r134. Havent tried 410 yet. good to know that it does work on 410.
    Where do u guys buy ur reference bottle? Preferably some where in the...
  15. Replies
    50
    Views
    4,647

    I am intrigued on this matter as well. I was...

    I am intrigued on this matter as well.
    I was taught to adjust manifold pressure to 3.5" w.c as per specs but some will overfire by as much as 20% when adjusted to 3.5" w.c.
    So now I just clock...
  16. Replies
    14
    Views
    2,442

    I got this off ebay ...

    I got this off ebay

    http://cgi.ebay.com/Gas-Test-Gauge-30-PSI-Pressure-Max-1-FPT-/300514999328?pt=LH_DefaultDomain_0&hash=item45f816fc20

    & coupled with a 3.5" gauge at Wolseley and the...
  17. Replies
    7
    Views
    2,296

    Yeah i wasn't sure what i was looking at til u...

    Yeah i wasn't sure what i was looking at til u explained it - hard to tell from the pics.

    So what's with the duct tapes then?
  18. Thread: Soot Vacuum

    by dukebbb
    Replies
    12
    Views
    5,067

    Wow...I am shopping for a shop vac also. Didn't...

    Wow...I am shopping for a shop vac also. Didn't know they aren't the way to go for hvac field.

    Btw, i dont get the HP rating on electric equipments. How can they produce so much HP out of a puny...
  19. Replies
    15
    Views
    1,720

    I had the same dilemma a while back between...

    I had the same dilemma a while back between fieldpiece st4 and UEI DT302. I settled for the uei due to the large display: 2 inputs and differential at a glance.

    Been good so far...
  20. Replies
    34
    Views
    6,585

    I got the short pro & resettable 5a fuse from...

    I got the short pro & resettable 5a fuse from zebra.
    Glad I didn't buy stat analyzer, though i was pondering a good 5 minutes on it. My thought was about using jumpers instead.
  21. Replies
    286
    Views
    17,286

    http://www.youtube.com/watch?v=3uP-eb8Zz08 My...

    http://www.youtube.com/watch?v=3uP-eb8Zz08

    My last boss doesn't nitro purge either, hence the replacement of compressors every 2-3 yrs on the house tab - I think this has to do with his never been...
  22. Replies
    37
    Views
    4,969

    While he's over ask him to do an ESPanol test...

    While he's over ask him to do an ESPanol test too, you "might" have a partially blockage somewhere :D
  23. Replies
    40
    Views
    3,250

    Yes, part of the setup is measuring temp rise...

    Yes, part of the setup is measuring temp rise across the furnace and adjust the blower speed accordingly. If they didn't do it then you'll have an uncomfortable drafty house.
  24. Thread: Dope Fiend

    by dukebbb
    Replies
    19
    Views
    3,638

    I am curious, do you guys leave the last 2...

    I am curious, do you guys leave the last 2 threads bare of dope? The reason I asked cos my boss would dope it all the way and make fun of me for leaving them bare.
  25. Thread: Purge Tool

    by dukebbb
    Replies
    1
    Views
    832

    Purge Tool

    I looked all over the web couldn't find one i like. Where you guys get yours?
    My local dealer has one but too bulky. I am just curious whether you can fab one yourself. Like using 1/2 or 3/4 air...
  26. I started out with Electromechanical course @...

    I started out with Electromechanical course @ local college. It gives you great insight into control design and troubleshooting. I was supposed to be a millwright apprentice but found out hvac is...
  27. Replies
    7
    Views
    1,347

    Just like the guys changing their own motor oil...

    Just like the guys changing their own motor oil at home; some would crank the engine a few turns after the oil has drained to rid of old oil trapped in clearances. Dunno how effective it is though.
  28. Replies
    11
    Views
    2,275

    Sorry my bad, have the code in front of me now so...

    Sorry my bad, have the code in front of me now so it's more cleared;
    "Pipe fittings shall be made of malleable iron or steel"
    and yes galvanized pipe and fittings are permitted here too.

    So back...
  29. Replies
    11
    Views
    981

    i don't think the TH6320U1000 is a 2 stage stat

    i don't think the TH6320U1000 is a 2 stage stat
  30. Replies
    11
    Views
    981

    BaldLoonie you make so much sense I never thought...

    BaldLoonie you make so much sense I never thought of it that way. That's why i signed up for this site. I've learned so much so far. I think i am gonna be smarter than my boss some day.
  31. Replies
    11
    Views
    2,275

    This i've grasped; what puzzles me is why they...

    This i've grasped; what puzzles me is why they are not allowed?
    I thought all gas fittings have to be cast iron. So do street elbows made differently then?

    So far from this thread I see 2 good...
  32. Replies
    11
    Views
    981

    We put in 2 stage furnaces that will kickin the...

    We put in 2 stage furnaces that will kickin the 2nd stage after 15min operating. So 2 stage tstat is optional to our customers.
  33. Replies
    11
    Views
    2,275

    street elbow vs. reducing elbow

    I know there's been a street elbow thread before but i didn't address my question so here it goes:

    I saw my boss installed a reducing elbow the other day so i mistakenly thought it's the same as a...
  34. Replies
    9
    Views
    1,297

    This would fit my description - j/k . I just...

    This would fit my description - j/k . I just don't see the justification in spending $150 for an adapter. I rather have the 510 for that price.


    Here's my mod :D


    Thanks guys.
  35. Replies
    9
    Views
    1,297

    Testo 327 Addons

    Hi every one, I've been reading here for a while now I just got my new toy delivered, so have a few questions for you.

    Any one have pictures of the Pressure Testing Adapter (0554-1203) ? It goes...
Results 1 to 35 of 65
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine