Search:

Type: Posts; User: fms2k

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    359

    you could get in touch with Ultratech - they make...

    you could get in touch with Ultratech - they make the airflow measuring stations that Kele sells - and see if they have anything you can use or what they might recommend. as a manufacturer they may...
  2. Thread: JCI Pnuematics

    by fms2k
    Replies
    10
    Views
    451

    I would follow dapper's advice - call NECC....

    I would follow dapper's advice - call NECC. They're still in business and they sell and stock all of those pneumatic tools, wrenches, gauge adaptors, etc. for all the major brands - Honeywell,...
  3. Replies
    6
    Views
    410

    Pretty sure E-Mon does both water & gas in...

    Pretty sure E-Mon does both water & gas in addition to electricity.
  4. Replies
    3
    Views
    437

    are they t7350 communicating LON stats? if so,...

    are they t7350 communicating LON stats? if so, you have options. honeywell options include the WebStat controller {support up to 20 stats}, the WebVision controller {support up to 120 LON devices} or...
  5. Replies
    13
    Views
    760

    Also the Veris H8100 series with a BACnet comm...

    Also the Veris H8100 series with a BACnet comm card option.
  6. Replies
    13
    Views
    760

    E-MON Class 3000 meter has BACnet/IP & BACnet...

    E-MON Class 3000 meter has BACnet/IP & BACnet MS/TP option.
    Might be too pricey, though, for what your customer is looking to
    do but probably worth checking out anyway.
  7. Why not go to your friendly neighborhood...

    Why not go to your friendly neighborhood Honeywell distributor
    and buy Excel "over the counter". You can sign up to be a CAC
    for a whopping $300.00 and this will get you a copy of LONSpec
    so you...
  8. Replies
    14
    Views
    833

    Maybe you can look at possibly trying one, or...

    Maybe you can look at possibly trying one, or more,
    of the following:

    1.) Lock out the electric baseboard heat completely, thru
    the breaker panels, until the outside air temperature drops
    below...
  9. Thread: Honeywell T stat

    by fms2k
    Replies
    2
    Views
    314

    try this link: ...

    try this link:

    http://customer.honeywell.com/techlit/pdf/63-0000s/63-2606.pdf

    honeywell also has a new {free download} application called
    T'statSpec that works like the old LonStat...
  10. Thread: stafa

    by fms2k
    Replies
    1
    Views
    293

    try this site:...

    try this site:
    http://www.plccenter.com/buy/SIEMENS/FWT1G
  11. Replies
    5
    Views
    620

    By sysint: "So, what I'm saying is you need a...

    By sysint:

    "So, what I'm saying is you need a plan. The plan needs to be based on knowledge of protocols, what is available, what is a good business model for your company. As a smart guy posted...
  12. Replies
    5
    Views
    545

    look at the johnson controls s66aa-1 motor speed...

    look at the johnson controls s66aa-1 motor speed controller.

    http://cgproducts.johnsoncontrols.com/CAT_PDF/1922105.PDF

    designed to work with psc motors.

    they work with a 0-10 vdc control...
  13. Replies
    13
    Views
    1,561

    www.neccdelivers.com

    www.neccdelivers.com
  14. Thread: DPT-2015

    by fms2k
    Replies
    6
    Views
    695

    www.neccdelivers.com my experience is they...

    www.neccdelivers.com

    my experience is they have
    good inventory on the JCI
    stuff
  15. Replies
    9
    Views
    851

    if you have a JCI distributor you work with, use...

    if you have a JCI distributor you
    work with, use the UNT. it's a "no
    brainer" for you to configure this
    application in HVAC PRO.

    you can do it with a Honeywell
    Excel 10 as well. this stuff is...
  16. Replies
    15
    Views
    1,237

    www.neccdelivers.com they can get u what u...

    www.neccdelivers.com

    they can get u what u need.
    excellent support on JCI N2
    stuff, old Companion & Facil.
    and FX.
  17. Thread: Digital Display

    by fms2k
    Replies
    9
    Views
    831

    take a look at these guys - maybe more into what...

    take a look at these guys - maybe more into what
    you're looking for:

    www.lascarelectronics.com/
  18. I worked for Siemens & still say Belimo by far.

    I worked for Siemens & still say Belimo by far.
  19. Thread: 0-10 VDC SIGNAL

    by fms2k
    Replies
    1
    Views
    473

    take a look at this website:...

    take a look at this website:
    http://www.act-solutions.com/

    they hava a product called an ASA that
    might work for you.
  20. Thread: Barber Colman

    by fms2k
    Replies
    3
    Views
    431

    Is it being used as a valve actuator or damper...

    Is it being used as a valve actuator or damper actuator?
    This motor could be used either way.

    If it is a valve actuator, get the model number of the
    valve body so you can get a Belimo retrofit...
  21. Replies
    3
    Views
    939

    As a former employee from back in the Landis &...

    As a former employee from back in the Landis & Gyr Powers, Inc. days,
    I can tell you that Siemens branch offices have no need, or desire,
    to be aligned with anyone. If you're a mechanical...
  22. Replies
    6
    Views
    508

    the 357-0001 is a limitem. you can get the...

    the 357-0001 is a limitem.

    you can get the infor you need at:

    www.neccdelivers.com
  23. Replies
    6
    Views
    709

    try this company: www.neccdelivers.com they...

    try this company:

    www.neccdelivers.com

    they are a siemens/powers distributor
    and have detailed "cut" sheets on all
    old powers controls going back some
    30 years.

    they will provide you all...
  24. Thread: Control drawings

    by fms2k
    Replies
    8
    Views
    793

    We can do that for you. Whether the controls are...

    We can do that for you. Whether the
    controls are pneumatic, electronic or
    DDC. Have been doing it for years.

    Send me an e-mail if you want to
    discuss. E-mail address is in my profile.
  25. Replies
    12
    Views
    1,189

    I have seen these boxes where the entire air...

    I have seen these boxes where the entire air valve
    assembly is removable. Able to drop the whole thing
    right out of the bottom of the vav box. If you can do
    that, then remove it and in effect make...
Results 1 to 25 of 85
Page 1 of 4 1 2 3 4