Search:

Type: Posts; User: superd77

Page 1 of 14 1 2 3 4

Search: Search took 0.01 seconds.

  1. I use a pan under the unit with a cut-off switch...

    I use a pan under the unit with a cut-off switch too. It sounds like your drain may have been clogged from the older unit and not the new one. I've had this happen once before. Changed out the...
  2. Replies
    6
    Views
    744

    The louvered cabinet by far is better. It...

    The louvered cabinet by far is better. It protects the coil from anything. If the cost is close, that should be the deciding factor. JMO
  3. Replies
    9
    Views
    1,453

    Go with the Trane. You will have less problems...

    Go with the Trane. You will have less problems and it will last a lot longer for you too.
  4. Replies
    6
    Views
    964

    Sorry to inform you sir (or madam) but if your...

    Sorry to inform you sir (or madam) but if your Gooooman unit hasn't been serviced in a few years, now is the perfect time. I have found that most if not all Goooman package unit heat exchangers...
  5. Replies
    86
    Views
    10,213

    Just be quick about it!!!:)

    Just be quick about it!!!:)
  6. Replies
    16
    Views
    3,170

    It appears that the spiral duct is not reduced...

    It appears that the spiral duct is not reduced after the registers. This will cause low static and make the supply air extremely slow, cold and cause unwanted condensation.

    It's hard to tell...
  7. Thread: Capacitors

    by superd77
    Replies
    10
    Views
    1,021

    Just like checking a 9v battery. If it don't...

    Just like checking a 9v battery. If it don't tingle a little it's bad!!
  8. Replies
    12
    Views
    1,052

    I'm thinking he's restricted at the new drier. ...

    I'm thinking he's restricted at the new drier. Not sure. He's going back this afternoon, maybe he left something out.
  9. Replies
    12
    Views
    1,052

    Do you think a bi-flow would blow the desiccant...

    Do you think a bi-flow would blow the desiccant out?? I think they have screens to prevent just that??? IDK??
  10. Replies
    18
    Views
    2,323

    The extra water in the pan won't go away. The...

    The extra water in the pan won't go away. The pan is designed to hold some water even after the unit shuts off.

    First things first, open all the vents. Just cause you close some don't mean...
  11. Replies
    12
    Views
    1,052

    He said he put the filter in the discharge line. ...

    He said he put the filter in the discharge line. About a foot away from the compressor. Mufflers in the discharge is what you've been seeing. Not driers!
  12. Replies
    12
    Views
    1,052

    He definitely said discharge line.

    He definitely said discharge line.
  13. Replies
    12
    Views
    1,052

    Freezing package unit

    Goodman 5 ton package str-8 air. My colleague changed the compressor out. (pins broke off in molded plug). He said he put a drier in the " discharge" line between the coil and compressor. Now he...
  14. Replies
    18
    Views
    2,323

    The drain needs to have a ptrap installed. The...

    The drain needs to have a ptrap installed. The negative pressure on the drain will cause the air handler to hold water in and when it shuts off the water will rush down the drain. Sometimes...
  15. Replies
    5
    Views
    814

    Love my sman3 gauges!!!

    Love my sman3 gauges!!!
  16. Replies
    35
    Views
    4,520

    Milwaukee is my choice. The M12 line is awesome!...

    Milwaukee is my choice. The M12 line is awesome! A charged battery lasts for a couple weeks and the drill itself has a battery life display. Makita don't have that.
  17. Thread: R-410 issues?

    by superd77
    Replies
    10
    Views
    903

    So you got your universal EPA card.... And no one...

    So you got your universal EPA card.... And no one there or around you mentioned anything about 410-22 conversion??? Sorry, but this trade can't be taught from the yard sale. You need actual training...
  18. Replies
    17
    Views
    2,418

    So you must be an engineer? Lol

    So you must be an engineer? Lol
  19. Replies
    17
    Views
    2,418

    So why did your neighbor put in the last one?? ...

    So why did your neighbor put in the last one??

    Universal tech in what??
  20. Replies
    13
    Views
    2,388

    Yes, all of the units with small slabs in them...

    Yes, all of the units with small slabs in them have been leaking. And I haven't been able to get any labor or refer from them either.
  21. Replies
    13
    Views
    2,388

    Yep!

    Yep!
  22. Replies
    9
    Views
    802

    I can see the unit short cycling at 50 degrees. ...

    I can see the unit short cycling at 50 degrees. If its 50 in the house, then that's the temp of the air blowing over the heat exchanger. This low of a temp is likely to cool the chamber down...
  23. A zone system would work fine. When only one zone...

    A zone system would work fine. When only one zone calls the excess air recirculates through the bypass. This will cause the supply air to drop even lower and help the one zone to satisfy faster. ...
  24. Replies
    44
    Views
    3,819

    Ditto!!! The sman3 is my first set. No...

    Ditto!!! The sman3 is my first set. No complaints.....yet. :)
  25. Thread: It's A Trap!!

    by superd77
    Replies
    27
    Views
    2,863

    They are used to evaporate condensate since they...

    They are used to evaporate condensate since they usually don't have open drains
  26. Thread: Hard starts

    by superd77
    Replies
    6
    Views
    649

    I've had both recips and scrolls have hard starts...

    I've had both recips and scrolls have hard starts with or with out TXV's
  27. Replies
    3
    Views
    1,033

    You need a pro to check it out. Could be a dozen...

    You need a pro to check it out. Could be a dozen things.....and no, you can't change the plunger in a solenoid. You have to change the whole valve.
  28. Replies
    6
    Views
    1,042

    How do you know it's not shifting??? Temp...

    How do you know it's not shifting??? Temp difference?? What's your pressures??
  29. Thread: Hello

    by superd77
    Replies
    5
    Views
    882

    And your question is??:)

    And your question is??:)
  30. Replies
    10
    Views
    1,139

    Are you on Florida?? I thought units on average...

    Are you on Florida?? I thought units on average didn't last that long down there?? 5 to7 years?? I may be wrong
  31. Replies
    14
    Views
    1,234

    NO.........NO.......YES.......YES if you held...

    NO.........NO.......YES.......YES

    if you held the bulb in your hand for five minutes and no change occurred then the valve is stuck. Let the guy do his job and change it out.....it's probably...
  32. Replies
    14
    Views
    1,234

    With a 20 degree subcool it looks like he dumped...

    With a 20 degree subcool it looks like he dumped some in to see if his suction would come up.
  33. Replies
    18
    Views
    2,276

    First things first. Check for smoke detectors in...

    First things first. Check for smoke detectors in the ducts. If you look at the diagram there is a note usually indicating a place for fire alarm wiring.

    If that ain't it you can look at the...
  34. Haha!! Only if your straight!! I call it a moral...

    Haha!! Only if your straight!! I call it a moral law.
  35. Thread: Run Capacitor

    by superd77
    Replies
    19
    Views
    1,816

    What readings from the "ohm" setting tells you...

    What readings from the "ohm" setting tells you it's working properly ???

    What does ohming the cap tell you??

    Curious.
  36. Replies
    2
    Views
    1,059

    That unit should have a spark that lights the...

    That unit should have a spark that lights the main burners. Remove the burners(shot burners) and clean them with a wire brush. Sounds like they might be stopped up with rust.

    While you are...
  37. Job well done.

    Job well done.
  38. Replies
    15
    Views
    3,141

    Did they leave the evap coil?? Them fans do...

    Did they leave the evap coil??

    Them fans do look like they spinning!:0
  39. Thread: DT

    by superd77
    Replies
    5
    Views
    554

    An attic install will lose a couple degrees. ...

    An attic install will lose a couple degrees. Crawl space not so much
  40. Replies
    11
    Views
    2,527

    Chinese contractors don't last long at all. Just...

    Chinese contractors don't last long at all. Just recently had 2 out of 4 brand new contractors bad out of the box.
    Nothing is made with quality anymore!
  41. Replies
    13
    Views
    1,572

    $12 per 100lbs. No matter what we do to them!! ;)

    $12 per 100lbs. No matter what we do to them!! ;)
  42. Replies
    9
    Views
    2,596

    Are you asking about p-trapping the drain?? Or...

    Are you asking about p-trapping the drain?? Or the copper??

    Yes on the drain, no on the line set.
  43. Replies
    15
    Views
    12,471

    Dang!!! How long has you been out of the field. ...

    Dang!!! How long has you been out of the field. Lol These pads been around at least 28 yrs. At least that's how old that crappy Lennox was friday when it died.
  44. Replies
    1,208
    Views
    42,177

    What's your definition of a hypocrite??

    What's your definition of a hypocrite??
  45. Replies
    1,208
    Views
    42,177

    It IS possible if we truly believe in our heart...

    It IS possible if we truly believe in our heart that Jesus did the same. My bible says no sin is greater than another...therefore my sin is just as bad as a murderer, rapist, dealer,etc...in Gods...
  46. Replies
    8
    Views
    1,301

    My Trane units I install have the bulb right at...

    My Trane units I install have the bulb right at the bend before the suction line comes out.
    I serviced a Gooooman unit the other day and their txv bulb is outside the cabinet. Insulated of course....
  47. Replies
    7
    Views
    683

    I use the tapatalk on my iPhone and it's awesome....

    I use the tapatalk on my iPhone and it's awesome. No problems at all!
  48. LOL!!!

    LOL!!!
  49. Replies
    34
    Views
    4,341

    I may be misunderstanding your post... Did you...

    I may be misunderstanding your post... Did you restrict the return?? Or did you put a bigger return in??
  50. Replies
    8
    Views
    902

    Have you eaten any Chinese food?? Then you...

    Have you eaten any Chinese food?? Then you probably have eaten a few strays... Lol!!!
Results 1 to 50 of 658
Page 1 of 14 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event