Search:

Type: Posts; User: FieldGen3

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    5
    Views
    554

    Just because I was in an extra special ticked off...

    Just because I was in an extra special ticked off mood I told my boss I wouldn't start it up until he had one of the electricians change the gfi outlet to a non gfi and install a ground fault...
  2. Replies
    5
    Views
    554

    Ice is a right, not a privilege!

    I can't stand office workers. Lazy, fat, a-holes that spend the majority of their day complaining about something.

    -"I'm too hot but the girl in the cube next to me is too cold. Can you turn up...
  3. Replies
    10
    Views
    833

    Yea I'm using part 47, and it's all in the right...

    Yea I'm using part 47, and it's all in the right direction. Looking closer at the newer version they changed part 47 "rod-hub" to part 29 "lever-drive" and part 43 "slider-rod" is now part 31 "arm...
  4. Replies
    10
    Views
    833

    Hobart CLPS86E conveyor drive problems

    Hobart CLPS86E
    Serial 85-1073933
    ML 138176

    A little history... This machine burnt the conveyor drive motor. My best guess of what happened was a snowball effect starting with the screw and...
  5. Replies
    21
    Views
    1,334

    Was it a turbo-air? I saw one like that once. I...

    Was it a turbo-air? I saw one like that once. I hated that unit.
  6. Replies
    24
    Views
    1,053

    How do I get a master crimper license? Seems like...

    How do I get a master crimper license? Seems like a sweet gig.
  7. Replies
    34
    Views
    1,023

    Flux coated

    Flux coated
  8. Replies
    7
    Views
    401

    Hoshi dcm270-bah needs auger and evap

    Inspecting this ice machine and I could feel the play in the upper bearing, no need for pin gauge. Removed the auger and at first glance it looked ok. I shine a light down the evap and low and behold...
  9. Replies
    0
    Views
    157

    Hoshi dcm270-bah needs auger and evap

    Inspecting this ice machine and I could feel the play in the upper bearing, no need for pin gauge. Removed the auger and at first glance it looked ok. I shine a light down the evap and low and behold...
  10. Replies
    34
    Views
    1,023

    45%

    45%
  11. Replies
    24
    Views
    1,053

    Thanks, this is what I was looking for.

    Thanks, this is what I was looking for.
  12. Replies
    24
    Views
    1,053

    This is exactly what I need them for, failed...

    This is exactly what I need them for, failed start components. I need a cheaper way to adapt a 3 N 1. The quick lugs are too expensive. I could butt splice the 1" lead from the overload, but I...
  13. Replies
    24
    Views
    1,053

    I run into the round pins more often but I'll...

    I run into the round pins more often but I'll take take either or both of you got them.
  14. Replies
    24
    Views
    1,053

    Crimp on terminals for fractional HP

    I'm looking for the solderless terminal connectors that will fit compressor terminals. I'm currently using the brass terminal repair kits, but it seems like overkill. Part number or link appreciated.
  15. Replies
    15
    Views
    1,372

    To answer some of the other questions, you do...

    To answer some of the other questions, you do need a water seal if you plan to pull the auger. I had the same model with 1/16" of scale. I soaked the auger in a bucket of cleaner overnight and that...
  16. Replies
    14
    Views
    1,231

    This unit is so not worth re-engineering with...

    This unit is so not worth re-engineering with txv' and or solenoids. I'm on ball with the recover and recharge. It'll have to wait until Monday though. Merry Christmas everyone.
  17. Replies
    14
    Views
    1,231

    Air entering condenser is 72, SH 37. New...

    Air entering condenser is 72, SH 37. New complaint but to be honest I don't know if anything has changed. The user happened to come in that morning to stock product during defrost. The thermometer on...
  18. Replies
    14
    Views
    1,231

    The only evap fan is running the right direction,...

    The only evap fan is running the right direction, no ice on coil, good airflow imo.
  19. Replies
    14
    Views
    1,231

    Flood back during off cycle?

    Turbo air M# TOM-40MB S#TMM4017Y011 (open air cooler 404a cap tube)
    Product barely keeping temp, 40 - 41 and creeps to 45 during defrost. This was the only real complaint.

    5 mins into cycle......
  20. Replies
    5
    Views
    1,007

    Thanks for the replies. I'll recommend Cleveland...

    Thanks for the replies. I'll recommend Cleveland for the new equipment.
  21. Replies
    5
    Views
    1,007

    Steamer recommendation

    I'm looking to replace a 200,000 BTU's/hr input, natural gas steamer with a kettle take off. I want to have a separate kettle and steamer. What's your opinion on the different brands from a...
  22. Replies
    0
    Views
    321

    True TR2RRT-2S-2S

    Looking for a wiring diagram. Anybody have one?
  23. Replies
    3
    Views
    1,525

    Thanks for the suggestion. Yea I have been to...

    Thanks for the suggestion. Yea I have been to Alto shaam site and even called them to ask what they use. The tech support lady couldn't give me an exact part number but we were on the same page as...
  24. Replies
    3
    Views
    1,525

    Hose help please

    Hey guys, I need help finding a flexible water supply hose for a new Alto-Shaam CTP7-20E install. My lines will be 3/4" copper and the fitting on the machine is 3/4" MGHT stainless. Manufacturer...
  25. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    3,120

    Agreed... Been running a few days now with no...

    Agreed... Been running a few days now with no problems.
  26. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    3,120

    Update: based on the feedback I think this unit...

    Update: based on the feedback I think this unit was some sort of custom install. There are quick connects to separate the drop in cold pan (I called it a cold rail before) Yes the cold pan was...
  27. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    3,120

    This unit has a cold rail.

    This unit has a cold rail.
  28. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    3,120

    Heck if I know, but I'm guessing it is still at...

    Heck if I know, but I'm guessing it is still at the factory
  29. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    3,120

    WTF Randell

    Salad bar cooler no worky. "Oh you're here to fix that thing? I've worked here for two years and it's never worked." Out of gas, schrader bubbles, tighten, vac and charge. It worky now. Only now it...
  30. Replies
    3
    Views
    1,666

    The temp control is definitely a knob and yes it...

    The temp control is definitely a knob and yes it is soldered directly to the control panel board. I think you answered my question I was just hoping it was a $20 chip vs a $2k+ board.
  31. Replies
    3
    Views
    1,666

    First time on Groen CC20-E

    We have a Groen Model# CC20-E Serial# C8948MS with an unresponsive cook temp control. I ran the diagnostics and when I get to the part where I have to turn the temp control knob one click at a time...
  32. Replies
    9
    Views
    1,056

    We have six like units in service. Typically if...

    We have six like units in service. Typically if one goes down and needs an extensive repair we swap the head out with a spare for as little down time as possible. Considering the parts removed I'm...
  33. Replies
    9
    Views
    1,056

    It would be rebuilt as a spare and it would...

    It would be rebuilt as a spare and it would definitely get new refrigerant when it is put back into service, but I would have a harder time ensuring multiple drier changes once it was. Maybe I can...
  34. Replies
    9
    Views
    1,056

    Resurrecting Ice-o-Matic

    We have an old ice-o-matic that was abandoned sitting in the back of our shop. I think it's an ICE1007HR, 404a, 208 3PH. It's been sitting there for 6+ months with the evaporator, txv and drier...
  35. Replies
    32
    Views
    4,873

    If a puller isn't available and turning the shaft...

    If a puller isn't available and turning the shaft doesn't free it, I try pushing the blade towards the motor and then sanding the area was the hub met the shaft.
  36. Replies
    23
    Views
    2,474

    Has anybody had luck using an ETC in this...

    Has anybody had luck using an ETC in this application? Jamb the sensor in the coil, set-point 18, diff 19. You might be able to experiment with the set-points and find a sweet spot.
  37. Replies
    12
    Views
    1,524

    Doesn't it suck in a bunch of air while you do...

    Doesn't it suck in a bunch of air while you do that? Even if you run the vacuum longer after the switch why not avoid introducing non-condensables by making the switch while still positive? Or you...
  38. Replies
    12
    Views
    1,524

    How are you removing your liquid line hose while...

    How are you removing your liquid line hose while the unit is under vacuum?
  39. Thread: condenser

    by FieldGen3
    Replies
    2
    Views
    724

    http://www.cpsproducts.com/images/products/xs/MT69...

    http://www.cpsproducts.com/images/products/xs/MT69_CPS-molecular-transformator-recovery_31.jpg

    Made me think of this... But google disagrees
  40. Replies
    133
    Views
    12,532

    Thanks for all the feedback. I agree that...

    Thanks for all the feedback. I agree that subcooling as a charging method on systems with a receiver is useless.
  41. Replies
    4
    Views
    2,714

    I need a rig that can fit in the bottom section...

    I need a rig that can fit in the bottom section of a rack and hoist out a 2 hp semi with only 2 foot clearance or less.
  42. Replies
    133
    Views
    12,532

    Thanks, I'll stop worrying about it.

    Thanks, I'll stop worrying about it.
  43. Replies
    133
    Views
    12,532

    Yea I feel good about that system it just made me...

    Yea I feel good about that system it just made me think in general that water cooled condensers could easily be overcharged. I guess it doesn't really matter as long as the receiver can hold it?
  44. Replies
    133
    Views
    12,532

    How can I tell if walk in is over charged?

    So I had to change a LLSV the other day. Pump the unit down, changed the valve, pulled vacuum, opened the king valve and started checking a few things out. Glass was clear, superheat was 3, so I...
  45. Replies
    5
    Views
    748

    I'm only guessing at what you are describing but...

    I'm only guessing at what you are describing but in general cable ties just keep bundles of wire neatly out of the way. As long as they aren't going to get damaged by a fan or a flame I wouldn't...
  46. Replies
    3
    Views
    579

    So far I've been lucky that my facility mostly...

    So far I've been lucky that my facility mostly uses the same drive for everything. I have a cheat sheet of the parameters and control wire terminations. On the high voltage side I've had bad...
  47. Replies
    5
    Views
    748

    I wouldn't worry about it as long as the wires...

    I wouldn't worry about it as long as the wires are out of the way.
  48. Replies
    5
    Views
    748

    Push mount cable ties

    Push mount cable ties
  49. Replies
    8
    Views
    4,278

    Good to know. Are you satisfied with the gauges...

    Good to know. Are you satisfied with the gauges otherwise?
  50. Replies
    8
    Views
    4,278

    Thanks for the reply. The picture of those gauges...

    Thanks for the reply. The picture of those gauges makes them look a little more durable than others. Should I not worry so much about them bouncing around in the truck? I am thinking of getting two...
Results 1 to 50 of 58
Page 1 of 2 1 2