    The local branch around here has tried to get...

    The local branch around here has tried to get "service" contracts in facilities with other control systems, but most of they time the bite off more that they can chew / swallow.

    kontrol out
  2. Cash money! kontrol out

    Cash money!

    kontrol out
  3. So it's operator error and not that rascally...

    So it's operator error and not that rascally devil BACnet? Who would have thought?

    kontrol out
  4. Replies
    10
    Views
    469

    I know, right? You could use the DSP sensor...

    I know, right?

    You could use the DSP sensor to maintain pressure setpoint, then use the OA CFM flow meter (sensor?) to maintain the min OSA requirement, but you still need to control the RA and...
  5. Replies
    10
    Views
    469

    LOL WUT?????????? kontrol out

    LOL WUT??????????

    kontrol out
  6. Or an AMR. kontrol out

    Or an AMR.

    kontrol out
  7. Replies
    8
    Views
    411

    Mammoth, Seasons 4, ClimateMaster, Systacon,...

    Mammoth, Seasons 4, ClimateMaster, Systacon, Liebert, Carrier, Triatek (Blue Ridge Technologies) to name a few. I have also seen it in a couple of different chillers but can't remember the brand off...
  8. ANSI vs ISO? kontrol out

    ANSI vs ISO?

    kontrol out
  9. Replies
    10
    Views
    469

    You could also Google honeywell grey manual pdf...

    You could also Google honeywell grey manual pdf and download it. It is a great resource and has details on most of the common building controls sequences and applications.

    kontrol out
  10. Replies
    5
    Views
    308

    Drac, Got me and this other guy mixed up. I...

    Drac,

    Got me and this other guy mixed up. I have come across this issue in the past and it pertains to the character set used by the controller. Never tried both on the same network but some...
  11. Replies
    16
    Views
    945

    I have a spare 511 laying around, for the right...

    I have a spare 511 laying around, for the right price it could be yours. Email is in my profile.

    kontrol out
  12. Replies
    3
    Views
    375

    MSTP - 76.8Kbs ARCnet - 156Kbs Ethernet/IP -...

    MSTP - 76.8Kbs ARCnet - 156Kbs Ethernet/IP - 100Mbs

    Never had an issue running 76.8Kbs on DDC manufacturers devices, rare occasions with OEM (VFD, chiller, boiler etc) had to lower it due to OEM...
  13. Replies
    5
    Views
    1,062

    All Your Base Are Belong To Us kontrol out

    All Your Base Are Belong To Us

    kontrol out
  14. LOLWUT? kontrol out

    LOLWUT?

    kontrol out
  15. I don't think the RS Plus (although zone temp may...

    I don't think the RS Plus (although zone temp may be able to be exposed as BACnet) or zone controller have equivalent BACnet objects. The airflow microblock is a proprietary BACnet object and has...
  16. Replies
    1
    Views
    157

    Shouldn't be hard if you're using Continuum 1.9+...

    Shouldn't be hard if you're using Continuum 1.9+ or Struxture Ware. But as they say "All BACnets are equal, but some BACnets are more equal than others".

    kontrol out
  17. Replies
    33
    Views
    2,104

    Yep yep! What he said. kontrol out

    Yep yep! What he said.

    kontrol out
  18. So BACnet setpoint parameters must be in 6 and...

    So BACnet setpoint parameters must be in 6 and above. I would say that they don't have privileges to download to controllers. The only thing you can upload from the controller is parameters and I...
  19. Setpoints in ALC systems below version 5 (IIRC)...

    Setpoints in ALC systems below version 5 (IIRC) are part of the setpoint microblock that are not BACnet visible. Need to upgrade the firmware in the controllers and change the program file to use...
  20. In the dictionary under redundant it says check...

    In the dictionary under redundant it says check redundant.



    kontrol out
  21. Replies
    33
    Views
    2,104

    LOL kontorl out

    LOL

    kontorl out
  22. Replies
    37
    Views
    11,606

    EMP grenade works well for electronics. ...

    EMP grenade works well for electronics.

    kontrol out
  23. Replies
    37
    Views
    11,606

    I find 16 once calibration tools work best with...

    I find 16 once calibration tools work best with oldmatics.

    http://cdn.mscdirect.com/global/images/ProductImages/7534540-21.jpg

    kontrol out
  24. Replies
    299
    Views
    29,399

    Unfortunately, Delta holds their "partner" list...

    Unfortunately, Delta holds their "partner" list very close to their chest. A lot of other manufacturers have a list or map of their distributors / re-sellers online on their websites for anyone to...
  25. Replies
    55
    Views
    4,574

    http://i674.photobucket.com/albums/vv109/dalton711...

    http://i674.photobucket.com/albums/vv109/dalton711/Amen-Brother.jpg

    kontrol out
  26. Replies
    5
    Views
    427

    Binary code? kontrol out

    Binary code?

    kontrol out
  27. Replies
    5
    Views
    449

    It's not polite to scream and yell at us. If...

    It's not polite to scream and yell at us. If you're looking for a reliable control system, go to the source: Reliable Controls

    kontrol out
  28. Replies
    6
    Views
    330

    Off base as far as I know. Controllers are...

    Off base as far as I know. Controllers are programmed with VisualLogic (plug in for Microsoft Visio) and you might need BACTalk to load the controllers, not sure if yo cn load directly from...
  29. Replies
    3
    Views
    247

    Messy solution. It would be nice if they had...

    Messy solution. It would be nice if they had timed overrides built into all AO/BO/AV/BV points like a certain manufacturer does.

    kontrol out
  30. Replies
    3
    Views
    221

    Like all Delta products the firmware in the...

    Like all Delta products the firmware in the controller must match the revision of ORCAview to program it. Other versions of ORCAview should be able to view the controller but not program it (without...
  31. Isn't the 2 the BACnet device ID? Changing it to...

    Isn't the 2 the BACnet device ID? Changing it to 16 would make the packet to be sent to device 16 not priority level 16.

    kontrol out
  32. Replies
    10
    Views
    455

    This. I have seen a 16 motor fan wall section run...

    This. I have seen a 16 motor fan wall section run off four variable frequency drives. Four motors per drive, each with it's own contactor.

    kontrol out
  33. From my limited knowledge the router must be...

    From my limited knowledge the router must be configured via hyper-terminal and a null modem cable.

    kontrol out
  34. Replies
    4
    Views
    390

    Trash? kontrol out

    Trash?

    kontrol out
  35. Keep the teachers happy/comfortable so they don't...

    Keep the teachers happy/comfortable so they don't sic the teacher's union onto the district.

    kontrol out
  36. Replies
    55
    Views
    4,574

    I love how LON fanboi has to keep bringing the...

    I love how LON fanboi has to keep bringing the lvb subject up to justify their poor choice in protocol.

    kontrol out
  37. Replies
    7
    Views
    742

    You ain't kidding, and lots of them just have mb...

    You ain't kidding, and lots of them just have mb codes for names/descriptions.

    kontrol out
  38. Replies
    16
    Views
    1,777

    ALCshare forum has the weather program. ...

    ALCshare forum has the weather program.

    kontrol out
  39. Replies
    37
    Views
    11,859

    I have what you seek young padawan. Have no way...

    I have what you seek young padawan. Have no way to contact you other than using the force. My email is in my profile, reach out and contact me.

    kontrol out
  40. Thread: vav help

    by kontrolphreak
    Replies
    6
    Views
    497

    You can buy an over-the-counter VAV controller...

    You can buy an over-the-counter VAV controller from http://www.bacnetcontrol.com/shop/. This one here: http://www.bacnetcontrol.com/shop/hvac-controls/10-vav-controller-relay.html. Config software is...
  41. Replies
    33
    Views
    6,123

    Never mind. kontrol out

    Never mind.

    kontrol out
  42. Replies
    8
    Views
    747

    Please don't post your emails in any thread as it...

    Please don't post your emails in any thread as it is against site rules.

    kontrol out
  43. Replies
    16
    Views
    1,010

    Cylon buys AAM

    http://controltrends.org/2014/07/cylon-energy-inc-acquires-american-auto-matrix/

    kontrol out
  44. Replies
    3
    Views
    541

    If OAT is greater then 60degF and valid or...

    If OAT is greater then 60degF and valid or operator allows cooling when OAT is invalid and the follow (calculated in other parts of the program):
    System needs cooling.
    Economizer is in cooling....
  45. Replies
    7
    Views
    378

    A couple of vendors (Andover and Siemens) have...

    A couple of vendors (Andover and Siemens) have their own wireless BACnet/MSTP devices. Andover works as advertised, have not had any experience with Siemens' offering. Other option is using IP...
  46. Replies
    4
    Views
    661

    The most beneficial manual will be the Microblock...

    The most beneficial manual will be the Microblock Reference Guide and using EquipmentBuilder to generate programs that you can then dissect and learn about. The simulation feature in Eikon is an...
  47. Replies
    10
    Views
    584

    It probably is using a typical program for each...

    It probably is using a typical program for each piece of typical equipment. Each program has an address in the Ivu to CCN router (just a guess that this is where the programs reside), program 1 has...
  48. Replies
    25
    Views
    2,882

    I have had issues with Danfoss and not setting...

    I have had issues with Danfoss and not setting the max master in the highest MAC addressed drive. I would set it to a couple of addresses above it's MAC and see if that helps.

    kontrol out
  49. Replies
    25
    Views
    2,882

    My guess is JCI@38.4Kbs. As the MAC address...

    My guess is JCI@38.4Kbs. As the MAC address starts at 4, I know JCI reserve 0-3 and generally run at 38.4Kbs.
    Just a guess.

    kontrol out
  50. Software can be one of the freewares online such...

    Software can be one of the freewares online such as WACnet or InneaSoft BACnet Explorer ( demo version ) and even some on SourceForge, device is Contemporary Controls portable BACnet/MST router...