  1. Replies
    7
    Views
    1,076

    I particularly like the needless use of 90’s in...

    I particularly like the needless use of 90’s in the liquid line.
  2. Replies
    40
    Views
    5,642

    All that, and i'll bet all the customer needed...

    All that, and i'll bet all the customer needed was a run cap. hahaha
  3. Replies
    15
    Views
    917

    Wheel appeared fine. Straight. No vibration.

    Wheel appeared fine. Straight. No vibration.
  4. Replies
    15
    Views
    917

    Yes. It is a GCS16. Sorry, typo. Anyhow yes...

    Yes. It is a GCS16. Sorry, typo. Anyhow yes the nameplate calls for a 3/4 hp motor. I removed a Century 3/4 hp 1075 3 speed motor rated for 4 amps. I don't know what was in it before that.
  5. Replies
    15
    Views
    917

    Blower Motor Failures

    No cool call at a hair salon. Failure was the blower motor. Unit is a Lennox GCS18-060-75-4Y. Customer stated that she has been at this location for 3 years and has had to replace this motor every...
  6. Replies
    11
    Views
    2,839

    That dip in the condensate line serves as the...

    That dip in the condensate line serves as the trap.
  7. Replies
    26
    Views
    3,125

    Yup!

    Yup!
  8. Replies
    26
    Views
    3,125

    New way to save 1000's on your power bill!

    I took this picture while standing on a busy sidewalk! It must be safe though, green wire is only a ground right? pfft...
  9. Replies
    17
    Views
    2,815

    It may not have been internally insulated, but it...

    It may not have been internally insulated, but it is now.
  10. Replies
    7
    Views
    1,464

    That was the norm here for several years, 2...

    That was the norm here for several years, 2 story's usually have piss poor access. Very scary some of the time. I have turned jobs down because of it.
  11. Replies
    3
    Views
    462

    Advise for new gauges...

    I just bought a set of digital gauges. SMAN-4. I also got a set of hoses with the ball valve shut off. I have always carried two sets of analog gauges, one for r-22 and one for 410a. Both with low...
  12. Replies
    13
    Views
    1,061

    I appreciate all the responses. That gives we a...

    I appreciate all the responses. That gives we a lot to look at & consider. I understand how poor airflow would affect efficiency but could somebody explain how it would cause compressor failure?...
  13. Replies
    13
    Views
    1,061

    Shorted compressor question

    I had a call yesterday where a 2 year old 410a compressor was shorted to ground (Trane XB13). I checked it at the compressor terminals. It is a 5 ton split unit (cool only). I don’t have any history...
  14. Thread: candle soot

    by SinCityKid
    Replies
    16
    Views
    1,174

    Electric candles ...

    Electric candles

    http://www.batteryoperatedcandles.net/
  15. Replies
    13
    Views
    3,968

    Go home A/C, your drunk

    Came across this condenser the other day. Homeowner said he backed into it with a backhoe 9 years ago. Said he has never had 1 problem with it and it worked well. I was there to work on the other...
  16. Replies
    7
    Views
    830

    ahhh. that makes sense. Thx

    ahhh. that makes sense. Thx
  17. Replies
    7
    Views
    830

    Fan motor mystery???

    I went to a no cool call yesterday. 5 ton ICP heat pump split unit. Owner said that nothing was running on the condensing unit so he hit the top of it with his fist and the fan began to run but not...
  18. Replies
    9
    Views
    922

    I'm not going to move it. But for my educational...

    I'm not going to move it. But for my educational sake isn't the high side pressure the same between the compressor and the metering device +\- a couple psi?
  19. Replies
    9
    Views
    922

    So just cut the old one out and sweat in a...

    So just cut the old one out and sweat in a Schrader valve for the Mars option? PITA for a simple valve. Thanks for the info though!
  20. Replies
    9
    Views
    922

    It is running like that. We have highs of 112 and...

    It is running like that. We have highs of 112 and lows at night are 95 so my options are limited. I like your suggestion of tapping into the service port for a temporary pressure switch and I will do...
  21. Thread: Microfarads

    by SinCityKid
    Replies
    12
    Views
    1,068

    Microfarads

    Can anyone please explain to me exactly what a microfarad is and it's relationship to PSC motors and run caps in plain English. I know how to measure them on caps and match them to motors but that...
  22. Replies
    9
    Views
    922

    Pressure switch question...

    4 ton straight cool York condenser. 410a

    Mod#TCGF48S41S1A

    Ambient hit 112 last Saturday and unit shut down. When I got there I noticed the high pressure switch was open. Attached gauges and...
  23. Replies
    26
    Views
    5,606

    What problem did this cause that couldmt be...

    What problem did this cause that couldmt be covered by waranty?
  24. Replies
    5
    Views
    1,288

    condiot is conduit is conduit...

    Stopped for some Mexican food in San Diego. Looked up and saw this. For what it's worth the food was fricken delicious!

    369081369091369101
  25. Replies
    1
    Views
    756

    Help with Lennox condensing fan motor

    I need help determining the proper OFM & blade for 2 identical Lennox condensers (straight cool). I have a job at a bank repossessed house and someone stole both of the condensing fan motors and fan...