Search:

Type: Posts; User: ararams

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    24
    Views
    392

    How about erratic operation of the bin stat or...

    How about erratic operation of the bin stat or normal operation of the high pressure switch.
  2. Replies
    13
    Views
    405

    Maybe someone just strip the threads on the valve...

    Maybe someone just strip the threads on the valve stem.
  3. You are so right, yesterday a five year old shot...

    You are so right, yesterday a five year old shot his seven year old brother in his lower back over I guess, who get into the bath tub first .
  4. Replies
    6
    Views
    285

    That evap is stainless steel and is the only one...

    That evap is stainless steel and is the only one you can use real ice machine cleaner to remove the rust stains. Then get them some good water filters.
  5. Replies
    16
    Views
    579

    That is not impossible. I had one leaking at the...

    That is not impossible. I had one leaking at the stub to drier body connection, it took forever to find because every time the leak detector goes off I was checking solder joint.
  6. Thread: to funny

    by ararams
    Replies
    4
    Views
    641

    Wait untill you find them live wedged between the...

    Wait untill you find them live wedged between the micro channel coils of the larger yorks.
  7. Replies
    7
    Views
    1,099

    May be in Japan only registered recyclers can...

    May be in Japan only registered recyclers can strip any thing that has value. That is how it should be here anyway.
  8. Why? All you have to do is install a pressure...

    Why? All you have to do is install a pressure gauge with a manual reset needle. I will also place some Vaseline on the water inlet line to see if it melts.
  9. Replies
    27
    Views
    1,592

    The 90% of receiver capacity charge (-- lbs) Is...

    The 90% of receiver capacity charge (-- lbs) Is in Larkin condensing unit manual .
  10. Replies
    27
    Views
    1,592

    Did he tell you what the ambient should be when...

    Did he tell you what the ambient should be when doing this.
  11. Replies
    9
    Views
    773

    There are surface mount circuit breakers, these...

    There are surface mount circuit breakers, these were mounted with two metal tabs and used by Hussmann in their condensing units.
  12. Replies
    69
    Views
    4,197

    Maybe someone found a video made in the 60s.

    Maybe someone found a video made in the 60s.
  13. Replies
    28
    Views
    1,485

    I can understand not seeing a toddler behind an...

    I can understand not seeing a toddler behind an suv but a nine year old.
  14. Replies
    28
    Views
    2,713

    Do these driers have a screen and pad on both...

    Do these driers have a screen and pad on both sides?
  15. Thread: 422-D

    by ararams
    Replies
    17
    Views
    1,041

    Russell sierra units have no reciever nor head...

    Russell sierra units have no reciever nor head pressure control.
  16. Thread: 422-D

    by ararams
    Replies
    17
    Views
    1,041

    I said the same thing as JP ,when someone install...

    I said the same thing as JP ,when someone install a 5t rudd ac condenser replaced a larkin 5t ten +years ago and as of yeterday when I pass the building it was still there running I think. Guess I...
  17. Replies
    1
    Views
    315

    copeland FFAP condenser

    What do you think? One condenser can do it all, High,medium and low temp + multiple refrigerants.
  18. Replies
    28
    Views
    2,713

    That is what a drier that was working suppose to...

    That is what a drier that was working suppose to look like. It was asked to do more that's when the unit quit.
  19. Replies
    10
    Views
    840

    How Important is a Dryer? Nothing is important...

    How Important is a Dryer? Nothing is important until you need it, now what is the purpose of a drier again.
  20. Thread: POE Oil

    by ararams
    Replies
    16
    Views
    1,377

    What type of oil the system was in the original...

    What type of oil the system was in the original compressor? If mineral I would drain the poe from the new comp and replace with mineral then install. I will not deliberately mix those oils in large...
  21. Replies
    14
    Views
    1,098

    I would just put my recovery tank inside the...

    I would just put my recovery tank inside the bucket of water (with some ice if available) and let it the recovery machine run.
  22. Replies
    5
    Views
    582

    This is where the hydraulic tubing expander comes...

    This is where the hydraulic tubing expander comes in handy.
  23. Replies
    14
    Views
    1,807

    Get someone to add a fresh air supply to your air...

    Get someone to add a fresh air supply to your air handler and redo your dust test while the house is under positive pressure.
  24. Replies
    17
    Views
    753

    made in the usa

    Why stick to "Made in the the USA". Let's make is better "Made in the USA and owned by Americans". This way we keep the profit here.
  25. IT has something to do with the internal volume...

    IT has something to do with the internal volume of the related parts including refrigerant, condenser design and ambient temp. There was a manufacturer with a similar design whose units also lasted...
Results 1 to 25 of 110
Page 1 of 5 1 2 3 4