Search:

Type: Posts; User: ChaseW

Search: Search took 0.00 seconds.

  1. Replies
    0
    Views
    427

    Angler Tool For Duct

    I Have An Angler Tool From DC Tool Company, And There Are No Instructions With It. I Was Wondering If Anyone Here Might Know How To Use It
  2. Thread: Fieldpiece

    by ChaseW
    Replies
    133
    Views
    22,558

    I use my HS36 to check submersible pumps all the...

    I use my HS36 to check submersible pumps all the time. They are the best meter I have ever bought. Not only does it have all off the features I need(Volts, ohms up to 40m, remote amp head,...
  3. Replies
    3
    Views
    563

    CraziFuzzy- I like HPWH's a lot. I am the number...

    CraziFuzzy- I like HPWH's a lot. I am the number two installer in the Northeast-at least according to A. O. Smith. They are efficient, cost effective, and have a great warranty. I am actually...
  4. Thread: Drilling Wells

    by ChaseW
    Replies
    15
    Views
    4,043

    Mr. Waterpirate, you are indeed correct. My...

    Mr. Waterpirate, you are indeed correct. My dilemma is that I have a small lot, and drilling below 20' is prohibited. I am wondering if I have enough space to use helix probes or hyperloops
  5. Thread: Drilling Wells

    by ChaseW
    Replies
    15
    Views
    4,043

    Approx how deep and how many feet of hyperloop...

    Approx how deep and how many feet of hyperloop per ton is required? For a small lot is it a better choice than drilling?
  6. Thread: Drilling Wells

    by ChaseW
    Replies
    15
    Views
    4,043

    Mr. Sky, I See That You Use Hyperloops. How Well...

    Mr. Sky, I See That You Use Hyperloops. How Well Do They Work For You? Also Have You Ever Used Rehau Helix Probes?
  7. Thread: Drilling Wells

    by ChaseW
    Replies
    15
    Views
    4,043

    Yes I Do Understand That Nothing Is As Easy As It...

    Yes I Do Understand That Nothing Is As Easy As It Seems. There Are Many Things To Go Wrong, But As They Say, No Risk No Reward. I Would First Hire The Licensed And Experienced Driller, Procure The...
  8. Thread: Drilling Wells

    by ChaseW
    Replies
    15
    Views
    4,043

    Waterpirate, The Problem Is That There Is A Well...

    Waterpirate, The Problem Is That There Is A Well Driller In My Area That Thinks He Can Install Geothermals Without An HVAC Contractor. What They Do Is Bid Drilling Your Well, And Then Tell The Owner...
  9. Replies
    0
    Views
    659

    Lockformer Flanger

    Does Anyone Know Where To Get An Auto-Guide Power Flanging Attachment For A Pittsburgh Lock Model 24?
  10. Thread: Drilling Wells

    by ChaseW
    Replies
    15
    Views
    4,043

    Drilling Wells

    Does Anyone Drill Their Own Wells For Geothermal?
  11. Replies
    2
    Views
    1,228

    Residential Radiant

    Is It Possible To Use A Residential Geothermal To Do Radiant Cooling?
  12. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    Cavalieri85, That Was The One Thing I Didn't Like...

    Cavalieri85, That Was The One Thing I Didn't Like With Daikin. All Our Instructions Where In Japanese, Millimeters, And Some Parts Only Had Pictures.
  13. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    I Wish These Where Braze Joints, As These Flares...

    I Wish These Where Braze Joints, As These Flares Have Been The Worst Thing In The World To Get To Seal Up. I Thought Maybe There Was Something I Overlooked.
  14. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    Did Any Of You Guys Have Difficulty In Getting...

    Did Any Of You Guys Have Difficulty In Getting Your Flares To Seal On The Indoor Units?
  15. Replies
    0
    Views
    435

    Sheet Metal Question

    Why Would You Use A 13/16" Notcher Vs. A 1" Notcher?
  16. Thread: Hello

    by ChaseW
    Replies
    2
    Views
    840

    That Sounds Like A Good Idea, Thanks.

    That Sounds Like A Good Idea, Thanks.
  17. Thread: Hello

    by ChaseW
    Replies
    2
    Views
    840

    Hello

    Hello All, My Name Is Chase.
    I'm A Licensed HVAC Tech, Master Plumber, Master Electrician, Class A CDL Driver, Gas Line Installer, And Fire Sprinkler Tech.

    I Found This Site Thruough A...
  18. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    Mark Beiser, That's Good To Know That They Are...

    Mark Beiser, That's Good To Know That They Are Available In Residential.

    Nuclrchiller, Yes The Charge Is Determined By The Piping Length. That Is A Good Idea To Write The Piping Length On The...
  19. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    Glennac, From What I Understand The Purpose Of...

    Glennac, From What I Understand The Purpose Of The Three Pipes Is To Allow The Diffrent Indoor Units To Have One Heat And Another One Cool Simultaneously, While Being On The Same Outdoor Unit. Can...
  20. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    I Have A Second One To Finish In Two Weeks.

    I Have A Second One To Finish In Two Weeks.
  21. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    Ryan, No Specific Questions, I Have Just Finished...

    Ryan, No Specific Questions, I Have Just Finished Installing My First One And Thought It Was Very Neat Technology. Couldn't Really Find Anything About It Online, So I Figured I Would Ask. I Think...
  22. Thread: Daikin VRV

    by ChaseW
    Replies
    49
    Views
    7,060

    Daikin VRV

    Has Anyone Done An Install Of A Daikin VRV System? What Was Your Opinion Of The System Compared To A Standard Split System?
Results 1 to 22 of 31
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event