Search:

Type: Posts; User: jrpsimivalley

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    26
    Views
    1,755

    15 seer 2 1/2 ton hp

    15 seer 2 1/2 ton hp
  2. Wow below 30 he...that's like almost...Impossible!

    Wow below 30 he...that's like almost...Impossible!
  3. Wow?....???

    Wow?....???
  4. Replies
    11
    Views
    1,802

    But the maintenance guy still got his spiff for...

    But the maintenance guy still got his spiff for selling it this is what our trade is becoming might as well become a gardner
  5. Replies
    23
    Views
    1,853

    I hope u don't think a variable blower motor will...

    I hope u don't think a variable blower motor will overcome poorly designed zoning. That said bypass dampers are not used in true zoned systems where equipment is at least 2 stage and your smallest...
  6. Replies
    6
    Views
    838

    10

    10
  7. If its variable u Need to check static motor my...

    If its variable u Need to check static motor my be ramping up and hunting due to undersized duct work
  8. Replies
    5
    Views
    645

    Airflow or lack there of look at the duct work

    Airflow or lack there of look at the duct work
  9. Replies
    14
    Views
    2,419

    Check

    Check
  10. Replies
    14
    Views
    2,419

    U need to church the model plug in condenser call...

    U need to church the model plug in condenser call tech support
  11. Replies
    14
    Views
    1,724

    leaking capacitors

    if a run cap is leaking oil but tests within specs for mfd, do u still change it? want to get everyones opinion
  12. Replies
    16
    Views
    1,550

    if it was airflow wouldnt td b higher?

    if it was airflow wouldnt td b higher?
  13. Replies
    16
    Views
    1,550

    moisture?

    split system 5 ton rheem condensor all style coil/plenum horizontal suction line iced up at condesor not at coil pressures fluctuating high 220-249 low 53-68 sub cooling 30 superheat 3 piston...
  14. Replies
    8
    Views
    1,180

    call your carrier tech/dealer carrier has a buy...

    call your carrier tech/dealer carrier has a buy back program with all their 2 stage recips about 1000 dollars towards new equip
  15. either the accumulator or muffler

    either the accumulator or muffler
  16. Replies
    14
    Views
    1,267

    strange call

    arrive to find liqiud line at coil screaming hot go to condensor find fan running backwards(blowing down) pull disconnect, find 2 new caps and a cheap hardstart and see that fan motor looks new and...
  17. Replies
    15
    Views
    1,678

    guess i should have said the call was not about...

    guess i should have said the call was not about the cap, the outdoor fan motor was bad, just asking about the resistor for my own knowledge. if it is a bleed resistor why dont all caps have them?
  18. Replies
    15
    Views
    1,678

    resistor on cap

    went to call yesterday old trane ac only condensing unit (split system) compressor had 2 caps wired together ( one 15 and one 35) but the 35 had a small resistor between c and herm and when i...
  19. Replies
    33
    Views
    2,031

    way overcharged txv is prob wide open and your...

    way overcharged txv is prob wide open and your just raising pressure was this at your house or customers
  20. well I live in socal guess ill let my drivers...

    well I live in socal guess ill let my drivers license expire get an out of state id and anytime i get a ticket just change the id never pay for tickets but seriously we're being over run here, now...
  21. Replies
    23
    Views
    1,375

    [QUOTE=SuperTech2010;11817202][QUOTE=HJ...

    duh thats the dumbest advice ive heard in awhile
  22. Replies
    6
    Views
    701

    u need an ecm motor tester it plugs into the...

    u need an ecm motor tester it plugs into the module between board and module, high voltage stays put, then kick it on, it should run the motor thru all speeds, only way to tell if it's the board or...
  23. Replies
    69
    Views
    8,392

    are u in service? how much do u yourself generate...

    are u in service? how much do u yourself generate for the company? install what can u do on your own? when you have these numbers go to your boss and lay them out for him then see where everyone...
  24. Replies
    2
    Views
    735

    sanyo mini split

    I need a replacement for a 11yo sanyo ductless split model # ks1261 or i have to take this thing off the wall clean a caked blower wheel and re install this fancoil. dealer says model is...
  25. so you now about the 25 series are rep came last...

    so you now about the 25 series are rep came last month with specs on it a true variable compressor.....sweeeeeeet. have u seen the new 25 condesing furnace with the variable gas valve i know lennox...
  26. Replies
    34
    Views
    4,976

    exactly when i used to do new construction the...

    exactly when i used to do new construction the plumbers would run their drain lines to the unit but i would never let them touch my equipment
  27. Replies
    17
    Views
    5,114

    nice

    nice
  28. Replies
    14
    Views
    2,786

    or is that 1X supposed to b it?

    or is that 1X supposed to b it?
  29. Replies
    14
    Views
    2,786

    dont know if its code where u r but shouldnt it...

    dont know if its code where u r but shouldnt it have a base to raise it above grade
  30. hire a pro not an engineer

    hire a pro not an engineer
  31. how long will nitro filled r22 units b available?

    when do u think the gov. will put a stop to nitrogen filled r22 units if ever?
  32. meant west san fernando valley

    meant west san fernando valley
  33. mild summer in socal THIS SUCKS!!!!!!!!!!!!

    I work mostly in ventura and est san fernando valley, this summer is horrible temps are so mild anyone else feeling my pain?
  34. Replies
    33
    Views
    3,652

    im not trying to rip anyone off, just trying to...

    im not trying to rip anyone off, just trying to offer better system performance. I saw after i started the thread that the title could give the wrong idea. what i meant was if you guys thought it was...
  35. Replies
    37
    Views
    3,265

    here in ca hers rating(duct leakage and charge...

    here in ca hers rating(duct leakage and charge verification on all installs that are permitted). it a good rule but what it seems to do is push h.o. not to permit jobs which means going with...
  36. Replies
    21
    Views
    1,451

    why use the same guys tha tinstalled these "leaky...

    why use the same guys tha tinstalled these "leaky coils" in the first place? its not there fault if manufactuers parts leak for sure but many systems are under charged from the get go. u need...
  37. Replies
    23
    Views
    4,022

    just like zen said u need to make sure ur sub...

    just like zen said u need to make sure ur sub cooling is on with what the condensing unit calls for. a fellow tech found one the other day 7 yo and had perfect sc but sh was way high, bad txv....
  38. Replies
    33
    Views
    3,652

    thanks for the reply, what do u guys think of...

    thanks for the reply, what do u guys think of replacing tha cheap start thermistors with one?
  39. Replies
    33
    Views
    3,652

    hope u will still let me get my pro...

    hope u will still let me get my pro membership,are u in charge of that? sent in the email today how long should it take?
  40. Replies
    33
    Views
    3,652

    thanks twilly, not trying to sell anything thats...

    thanks twilly, not trying to sell anything thats not good for them or their system. I've been told by many that they are a way to reduce start up amp draw thus reduce energy consumption and lower...
  41. Replies
    26
    Views
    1,328

    great advice, guess i should start setting up...

    great advice, guess i should start setting up time to take my c-20 test(oh here in the states ca to be exact thats our license)
  42. Replies
    33
    Views
    3,652

    jury is still out need more opinions guys

    jury is still out need more opinions guys
  43. Replies
    17
    Views
    1,333

    i like the mini spit idea fujitsu halycon can...

    i like the mini spit idea fujitsu halycon can have multiple fan coils, or lg u can have a picture frame fan coil
  44. Replies
    26
    Views
    1,328

    all u owner/ops say that I wanna do it im just...

    all u owner/ops say that I wanna do it im just worried about providing for my fam in those first few years( 2 daughters(5 and new born) and an expensive wife(smokin hot). Gonna have to do it...
  45. personally i like the 4 in merv 10, eac's when...

    personally i like the 4 in merv 10, eac's when plates are full allow so much through u end up needing a evep coil cleaning in 5 years or less, if u do use one I would suggest using a 1 in filter in...
  46. Replies
    33
    Views
    3,652

    exactly the higher seer (more expensive) units...

    exactly the higher seer (more expensive) units come with them factory installed scroll or recip
  47. Replies
    33
    Views
    3,652

    if all amp draws are normal and it bypassed the...

    if all amp draws are normal and it bypassed the disconnect delay fuses, then what? These are one time trips not repeat offenders
  48. Replies
    26
    Views
    1,328

    ouch, thats the feeling in the back of my mind....

    ouch, thats the feeling in the back of my mind. Problem is i'm nervous to start over somewhere else again, plus my pay is preety high over here cause we are one of the more expensive in town(but...
  49. Replies
    53
    Views
    3,598

    ouch go out once an hour and hose down the...

    ouch go out once an hour and hose down the outdoor coils(while system is off) see if it helps. whats your insulation like, attic exhaust fan?
  50. Replies
    33
    Views
    3,652

    me too, I've been offering it when I find a...

    me too, I've been offering it when I find a tripped breaker,on top of a pm agreement of course. My thinking is that if the kit will lower initial amp draw it will help in not tripping breaker on hot...
Results 1 to 50 of 112
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event