  1. Thread: TEC failure

    by cameront
    Replies
    6
    Views
    974

    You can simulate the same failure if you...

    You can simulate the same failure if you disconenct the FLN or power supply. I have checked the temp sensor and wiring and appears ok, however a sensor fail or wiring fail would most likly be at...
  2. Thread: TEC failure

    by cameront
    Replies
    6
    Views
    974

    This was an existing fault. Upon taking the site...

    This was an existing fault. Upon taking the site over we had found a relay had been crudly wired in to reset the power supply to the controller. As above we started fresh. replaced the controller...
  3. Thread: TEC failure

    by cameront
    Replies
    6
    Views
    974

    TEC failure

    Hi all,
    I have a TEC wich is one of 12 controllers serving chilled water fan coil units with electric heat
    All have common power supply and all on the same FLN
    The TEC in question is showing...
  4. Thread: Siemens RWX62

    by cameront
    Replies
    11
    Views
    2,102

    Mail sent. Much appreciated for sharing the old...

    Mail sent.
    Much appreciated for sharing the old program. Ill be sure to help others where I can.
  5. Thread: Siemens RWX62

    by cameront
    Replies
    11
    Views
    2,102

    Thanks all I will keep looking, alternativly I...

    Thanks all
    I will keep looking, alternativly I might try and sell them a new controller.
  6. Thread: Siemens RWX62

    by cameront
    Replies
    11
    Views
    2,102

    Very much appreciated - Thankyou

    Very much appreciated - Thankyou
  7. Thread: Siemens RWX62

    by cameront
    Replies
    11
    Views
    2,102

    Siemens RWX62

    I have several RWX62 controllers with one that has dropped it settings. I read in the manuals that with the commissioning program and cable the settings can be coppied from one controller to another...
  8. Replies
    37
    Views
    3,600

    "Reliable controlls" all web based, no need for...

    "Reliable controlls" all web based, no need for on site computer (Keeps costs down) as server is built into main controller. To access system you can use any computer anywhere with internet access...
  9. Replies
    2
    Views
    944

    Gday i'm new here

    have read for some time now would like to contribute - interesting forum and looking forward the experience.