  1. Thanks for asking. He had a gas detector that he...

    Thanks for asking. He had a gas detector that he used to "snoop" the connections on the outside unit and a soap solution; then he did the same thing around the connections at the coil under the...
  2. Yes, Mr. Professional! That did it!

    Yes, Mr. Professional! That did it!
  3. Carrier Infinity adjustment assistance

    My unit was running constantly in the heat pump mode and I realized the refrigerant must be low last May. So I turned on "furnace only selected" (which is gas) but forgot what I did.
    The service...
  4. Replies
    25
    Views
    3,660

    Power vent "may" be fixed!

    I am sure that some of you reputable HVAC guys will love this! The power vent (PV) was DIRECTLY wired to the draft motor of the furnace (i.e. not using the 24v but direct 120v), so the draft motor...
  5. Replies
    25
    Views
    3,660

    The furnace is 58CVA090 with sn 1109a32312,...

    The furnace is 58CVA090 with sn 1109a32312, horizontal mount, no pressure switches replaced.
    We do have carbon monoxide detectors in the house, the vent pipe is type B and I can see the exhaust...
  6. Replies
    25
    Views
    3,660

    Excellent Point! I had not thought of that. My...

    Excellent Point! I had not thought of that. My furnace could be getting gummed up and the 1 yr warranty will be finished.
  7. Replies
    25
    Views
    3,660

    Thank you! I just looked at the book on the...

    Thank you! I just looked at the book on the furnace (pg 34) states just what you said. So the PV should run when the furnace is on! Now it just runs for 30sec in low, and constantly in high. This...
  8. Replies
    25
    Views
    3,660

    The PV was there from the old system. I told...

    The PV was there from the old system. I told them that even though Carrier said it was not necessary, that I would feel better having a PV. I suppose there is no way that I could speak to Carrier...
  9. Replies
    25
    Views
    3,660

    According to the contractor (and I don't really...

    According to the contractor (and I don't really trust them) Carrier said that the power venter is not necessary on this furnace, and that the furnace would exhaust itself through the vent pipe!
  10. Replies
    25
    Views
    3,660

    They told me there is a high and low connection...

    They told me there is a high and low connection on the furnace circuit boards, and the PV wiring was attached to the high. But it still comes on for 30 sec when it turns on.

    Are you saying that...
  11. Replies
    25
    Views
    3,660

    Power vent issue with Carrier furnace

    58CVA090-1-16
    This dual stage system is working fine and is installed under the house. The existing power vent (PV) was used with the new Carrier Infinity system. The furnace has its own exhaust...
  12. Yes, they were paid 1/2 up front, and the...

    Yes, they were paid 1/2 up front, and the remainder after installation. It worked after installation but needed some small adjustments so I paid.

    Aside from all the screw ups, no one has...
  13. UPDATE EVEN HARDER TO BELIEVE!

    UPDATE:
    This is day 8 after the failure I described above.
    The same tech I spoke of above arrived with the new compressor. Carrier called him back the NEXT DAY about noon. Carrier said he didnt...
  14. I dont know yet if "they" botched the install. ...

    I dont know yet if "they" botched the install.
    I know that I have been without a/c since Friday (6 days) and many professional members said they would have responded immediately to this type of...
  15. The compressor will be replaced tomorrow. But...

    The compressor will be replaced tomorrow. But you are at least somewhat correct. If I could "TRANSFER" my job to another dealer I would, but it looks like I am stuck with this company since they...
  16. Yes, I am still down and waiting for the guy to...

    Yes, I am still down and waiting for the guy to let me know what Carrier is going to do (i.e. replace compressor or the whole unit).
  17. They were not listed as a FAD. When I questioned...

    They were not listed as a FAD. When I questioned the head guy he said he would have to pay Carrier 7k to be listed as a FAD. They did vacuum the lines prior to hooking the outdoor unit up. When I...
  18. Compressor was cold (off for days) when he...

    Compressor was cold (off for days) when he checked it. He also pushed the relay and the fan hummed but didnt run. He hooked the lead from the fan to bypass the relay and pushed the fan to get it...
  19. What percentage of compressors from Carrier burn...

    What percentage of compressors from Carrier burn up in 30 days?
  20. Replies
    73
    Views
    4,194

    Test your comfort level in cold weather and factor that in

    Since you can select the outside temperature ranges of where you want your heat pump to operate at the thermostat, you can conduct an experiment. Set the heat pump to turn off and alternate fuel on...
  21. Extremely disappointed in Carrier! Hard to believe!

    :mad:
    You helped me pick it out. Installed 6 weeks ago:
    25HPA536H003
    58cva090-1-16
    csphp3612A1A.
    This is a 2 zone system controled with Infinity zoning.

    Fault 72, temperature cutout. ...
  22. Replies
    13
    Views
    859

    What is 2 stage zoning? It was my understanding...

    What is 2 stage zoning? It was my understanding that the system would adjust the vs blower for what was needed. This system has 2 zones coming off the coil, both are infinity zone controller.
  23. Replies
    13
    Views
    859

    A few more issues, zoning blower problems and fault 72 temperature cutout

    There are still some issues and I have three things to mention:
    1. Thanks for the suggestions regarding the power vent which the contractors resolved. Interestingly, Carrier reiterated that the...
  24. Replies
    13
    Views
    859

    They had some discussion about adding a relay but...

    They had some discussion about adding a relay but they wanted to get the Carrier guy to look at it. They dont know which leads to use for the signals.

    I have the system on HP only until this is...
  25. Replies
    13
    Views
    859

    Power venter with Infinity?

    OK, here is my system which many of you helped with. I dont know if I should but the new thread represents new issue:
    25HPA536H003
    58cva090-1-16
    csphp3612A1A.
    This is a 2 zone system...