  1. Replies
    12
    Views
    767

    Why not just fit a non return valve to the...

    Why not just fit a non return valve to the discharge line ,would solve backflow if thats the only issue.
  2. Replies
    22
    Views
    768

    I have worked on these type freezers a lot ,...

    I have worked on these type freezers a lot , drag unit outside ,line tap and blow off ,cut out drier and flush with nitro couple times, then weld away to your hearts content.Remove line tap weld in...
  3. Replies
    86
    Views
    6,836

    Good to hear you are getting to the bottom of the...

    Good to hear you are getting to the bottom of the problem .A most unusual conclusion goes to show we are all still learning everyday.
  4. Replies
    86
    Views
    6,836

    I would disconnect the oil equalising system...

    I would disconnect the oil equalising system altogether ,you have a system with individual oil control no point in haven it if your going to link all the sumps.To my mind after reading all the posts...
  5. Replies
    86
    Views
    6,836

    Another possibility is that one of the henry...

    Another possibility is that one of the henry float valves could be stuck open .You really need to start isolating oil lines one at time assuming you have valves to see which compressor is moving the...
  6. Replies
    86
    Views
    6,836

    Is there any unloaders on the compressors . I...

    Is there any unloaders on the compressors . I have come across faulty unloader heads on similar satellite compressors to cause them to pump oil like theres no tomorrow.
  7. I have come across similar syptoms with 407c...

    I have come across similar syptoms with 407c where they were vapour charged by mistake,Might be worth reclaiming gas and recharging with liquid from a virgin cylinder.At the least it would clearly...
  8. Replies
    23
    Views
    2,402

    Thanks for clearing that up i knew there had to...

    Thanks for clearing that up i knew there had to be some issue with it because if fitting a 410 using existing pipework most air cons use a flushing cycle to collect the mineral oil out of the system...
  9. Replies
    23
    Views
    2,402

    Good point could be an old wives tale but id...

    Good point could be an old wives tale but id prefer to be careful than to be caught.
  10. Replies
    23
    Views
    2,402

    ya i know its a 410 was just saying no real need...

    ya i know its a 410 was just saying no real need to flush as there be no sludge or anything formed as the 22 would mix ok
  11. Replies
    35
    Views
    4,988

    A lot of daikins in around europe if you look up...

    A lot of daikins in around europe if you look up a particular european forum you should find all you need to know,cant comment myself as have not worked on many of them
  12. Replies
    23
    Views
    2,402

    Id just change the gas . r22 has no problem...

    Id just change the gas . r22 has no problem mixing and running with poe oil ,Its the 410 that wont mix with the 22s mineral oil
  13. Thread: oxy/acet

    by coldjoe
    Replies
    32
    Views
    2,110

    405081 Brazing glasses can look cool

    405081 Brazing glasses can look cool
  14. Replies
    17
    Views
    1,444

    Get good results with my fieldpiece srl2...

    Get good results with my fieldpiece srl2 ,rechargeable and sturdy plus nice attachments
  15. Thread: oxy/acet

    by coldjoe
    Replies
    32
    Views
    2,110

    Tinted saftey glasses rated for brazing can be...

    Tinted saftey glasses rated for brazing can be bought in several places online .A coworker of mine who was brazing daily on sites is now having serious trouble with sight loss.Its probably too late...
  16. Replies
    13
    Views
    1,093

    Another advantage of placing in doors is when the...

    Another advantage of placing in doors is when the drier is near its capacity if it gets heated up on a hot day outside it will lose moisture back into the system
  17. Replies
    3
    Views
    683

    I always nick with a hacksaw first even if i know...

    I always nick with a hacksaw first even if i know theres no gas in ,seen a coworker getting a very nasty burn when he cut into system he thought was pumped down .He locked out the case with its own...
  18. Replies
    28
    Views
    1,882

    Great posts dowadudda ,very informative,not used...

    Great posts dowadudda ,very informative,not used to low ambient systems here and very little hot gas defrosts used in supermarkets
  19. Replies
    45
    Views
    3,853

    The only cases i work on are small 100 grams but...

    The only cases i work on are small 100 grams but most supermarkets here are now bringing it in on all the upright cases aswell,correct there is no stenching agent in r290 a lot of people might not...
  20. Replies
    45
    Views
    3,853

    the real engineers came before us like my father...

    the real engineers came before us like my father ,they worked with flammable ,exsplosive and they had no recovery units or vacuum pumps or any stuff like that ,they were real techs and pioneers,laid...
  21. Replies
    45
    Views
    3,853

    My father is a retired tech too he got a bad...

    My father is a retired tech too he got a bad burn on his hand from a metyl type refrigerant years ago,i was crapping myself the first hc fridge i fixed but its like everything else you just get used...
  22. Replies
    45
    Views
    3,853

    That video is only showing how to service without...

    That video is only showing how to service without a flame,its perfectly acceptable to take a torch to a propane system once the dryer has been cut out and the system flushed with nitrogen a couple of...
  23. Thread: New to service

    by coldjoe
    Replies
    17
    Views
    1,463

    these house type units not really in use here ,do...

    these house type units not really in use here ,do they not come factory charged ,most ac here comes charged with specific weight of charge to be added for extra lineset lenghts ,makes life easy
  24. Replies
    45
    Views
    3,853

    Luckily in europe its legal to vent hydrocarbon...

    Luckily in europe its legal to vent hydrocarbon refrigerants .There are limits to the charges allowed in indoor cabinets 1kg in a basement,1.5kg on a shopfloor,2.5kg in a storeroom.thankfully the...
  25. Replies
    45
    Views
    3,853

    Have been repairing r290 chest freezers here for...

    Have been repairing r290 chest freezers here for a couple of years no explosions no dramas , best way to work on these is to wheel them outdoors.