Search:

Type: Posts; User: rayr

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    21
    Views
    496

    My error thought I was reading the freezer thread.

    My error thought I was reading the freezer thread.
  2. Replies
    21
    Views
    496

    40 lbs suction on a 404 freezer at set point????...

    40 lbs suction on a 404 freezer at set point???? That does not sound right....
  3. Replies
    9
    Views
    261

    x2. In 1979 (or there abouts) there was a...

    x2. In 1979 (or there abouts) there was a shortage of R-22 and the only thing I could ge was Dupont with Dytel in it.......I hated it.
  4. Thread: another tool bag

    by rayr
    Replies
    9
    Views
    839

    That bag really deserves a "Fluke" in place of...

    That bag really deserves a "Fluke" in place of that Fieldpiece
  5. Replies
    56
    Views
    2,560

    Must be really efficient to, huh?:whistle:

    Must be really efficient to, huh?:whistle:
  6. Replies
    56
    Views
    2,560

    That will prob outlive any newer units. Those...

    That will prob outlive any newer units. Those commercial units are NOT cheap.
  7. Thread: My Wife's Friend

    by rayr
    Replies
    8
    Views
    1,095

    Most times,, it is safer to take the money. :)

    Most times,, it is safer to take the money. :)
  8. When the frost is within 6 inches of the...

    When the frost is within 6 inches of the compressor when it reaches setpoint, it is just about right. Old school stuff. Never failed me in a pinch.
  9. In my experience, high side pressure measurements...

    In my experience, high side pressure measurements are not advisable due to the very small amount of refrigerant in the system. OMO.
  10. Replies
    8
    Views
    610

    United has a new one on the shelf. Jumper with...

    United has a new one on the shelf. Jumper with small magnet on each end. Works well on metal screw terminals. Not brass of course.
  11. Just what we need, another flavor of refrigerant...

    Just what we need, another flavor of refrigerant to carry around.
    :gah:
  12. Replies
    5
    Views
    668

    can that be used on an extension ladder?

    can that be used on an extension ladder?
  13. Thread: Made me laugh

    by rayr
    Replies
    12
    Views
    3,264

    We will be installing one in March. It has...

    We will be installing one in March. It has modulating gas valve to maintain 70 deg air temp. Will be 13 tons of air conditioning. Will have VFD for 73000 exhaust fan and MUA unit. This will service...
  14. Replies
    20
    Views
    3,503

    Third wolrd countries. Seen some insane stuff...

    Third wolrd countries. Seen some insane stuff work wise stuff in Caracus. Never want to go back.
  15. Replies
    16
    Views
    890

    CDave would have a field day with this. There is...

    CDave would have a field day with this. There is no such thing as "Negative Superheat". You may have negative temperature and/or negative pressure but not negagtive superheat. Best re-check.
  16. Replies
    24
    Views
    1,882

    If it were mine and I was using 134-a, I would...

    If it were mine and I was using 134-a, I would put a small receiver on it along with an expansion valve. POE and cap tubes are poblematic at times if the compressor over heats, especially if...
  17. Replies
    11
    Views
    592

    I bought my first one in 1965 and it was made by...

    I bought my first one in 1965 and it was made by GE for a very long time.
  18. Thread: Nice return room

    by rayr
    Replies
    9
    Views
    1,234

    Don't suppose they have CO detectors?

    Don't suppose they have CO detectors?
  19. Replies
    13
    Views
    1,020

    LOL

    LOL
  20. Replies
    36
    Views
    12,141

    A pilot relight kit should solve the problem....

    A pilot relight kit should solve the problem. Have installed a few over the years.
  21. Replies
    15
    Views
    1,598

    Headaches, death. No biggie! :)

    Headaches, death. No biggie! :)
  22. Replies
    10
    Views
    1,743

    Does it come in a spray can? :whistle:

    Does it come in a spray can? :whistle:
  23. Thread: Torpedo level

    by rayr
    Replies
    9
    Views
    597

    My I phone has a level/compass on it if I am in a...

    My I phone has a level/compass on it if I am in a pinch. I tend to opt for the plastic ones for thermostat installation. Less likley to leave that aluminum transfer mark on the wall if an ooooops...
  24. Replies
    21
    Views
    2,446

    Not legal to have a union in burner compartment...

    Not legal to have a union in burner compartment here!
  25. Replies
    4
    Views
    1,289

    "I had it serviced about 8 years ago"

    Customer complained of headaches and feeling nausea. Imagine that. Lucky they are alive. Installed new 50K boiler.
    http://i384.photobucket.com/albums/oo289/rrayr2003/NewBrunsPie2_zps91344e9c.jpg
    ...
  26. Replies
    148
    Views
    9,948

    There is no IMC 307 2.5 in the 2012 book.

    There is no IMC 307 2.5 in the 2012 book.
  27. Thread: Cold weather gear

    by rayr
    Replies
    14
    Views
    1,779

    Hell, I spent a year in northern Greenland and...

    Hell, I spent a year in northern Greenland and never needed one. Lots of -40 there and then some.
  28. Replies
    13
    Views
    1,749

    You cannot fix stupid.

    You cannot fix stupid.
  29. Thread: Leak repair

    by rayr
    Replies
    12
    Views
    1,910

    Wondering if that Female adapter is on a Flare...

    Wondering if that Female adapter is on a Flare fitting??
  30. Replies
    10
    Views
    2,413

    What was the problem?

    What was the problem?
  31. Did you at least do an acid test?

    Did you at least do an acid test?
  32. Replies
    27
    Views
    3,425

    That is a big flue coming off the furnace for 4...

    That is a big flue coming off the furnace for 4 outlets coming off the plenum. Are there more hidden, like about 6 or more????
  33. Thread: Hussman NIM-6

    by rayr
    Replies
    8
    Views
    1,822

    Newbie :) Maybe it is a new question?

    Newbie :) Maybe it is a new question?
  34. Replies
    35
    Views
    5,293

    Dyson.

    Dyson.
  35. Replies
    58
    Views
    4,191

    Why 3 fan coils?? I see about 20 feet of box by...

    Why 3 fan coils?? I see about 20 feet of box by counting the ceiling panels. Could have done with with 2 fan coils with 3 fans in it. Looks to me like the job is being worked backwards. Sizing the...
  36. Replies
    35
    Views
    4,668

    I just bought some of that. It is called...

    I just bought some of that. It is called "Unpurple Primer". I hate purple primer.
  37. Replies
    35
    Views
    4,668

    That hanger strap sure makes the job look bad. We...

    That hanger strap sure makes the job look bad. We use the regular pvc straps with the vinyl liner. There is NO way that I will install a humidifier in an attic. Talk about high liability.
  38. Replies
    14
    Views
    1,198

    The ice has to ber 32 degrees or colder.

    The ice has to ber 32 degrees or colder.
  39. Thread: What a Headache

    by rayr
    Replies
    6
    Views
    1,688

    What a Headache

    Customer complained of headaches and nausea. Had not been in basement for years and years. Lucky they did not die. First pic is of flue pipe, second is roll out maximus. Fixed it up with new boiler,...
  40. Thread: Step Drill Bit?

    by rayr
    Replies
    4
    Views
    754

    On my Bridgeport.

    On my Bridgeport.
  41. Replies
    29
    Views
    4,853

    Beside the crud, that motor has been in service...

    Beside the crud, that motor has been in service for a very long time.
  42. Replies
    14
    Views
    3,188

    Nice job. Only thing I would have done different...

    Nice job. Only thing I would have done different would have been to come off the side of the supply trunk instead of the bottom (where possible) with 2- 45's. Would have eliminated 1 elbow and made...
  43. The ones I use are aroung 4 watts per ft. They...

    The ones I use are aroung 4 watts per ft. They are available from 2 to 5 watts per foot. X2 on the correct supply voltage.
  44. Replies
    42
    Views
    2,411

    You need -10 to keep Ice cream hard.

    You need -10 to keep Ice cream hard.
  45. Replies
    18
    Views
    3,071

    It needed more heat. :grin2:

    It needed more heat. :grin2:
  46. If by LP you mean low pressure cut out control,...

    If by LP you mean low pressure cut out control, they cannot be used on a cap tube system. A lot of reachins are cap tubes.
  47. Replies
    14
    Views
    1,026

    This is a R-22 system. Can't set the cut in at...

    This is a R-22 system. Can't set the cut in at 40.....Most cut outs are 47 or close to it. (LPCO setpoints)
  48. Replies
    14
    Views
    1,026

    This is a R-22 system. Can't set the cut in at...

    This is a R-22 system. Can't set the cut in at 40.....Most cut outs are 47 or clos to it.
  49. Supply plenum is code here.

    Supply plenum is code here.
  50. SO2 refrigeration open refrigeration compressors....

    SO2 refrigeration open refrigeration compressors. Wellbuilt and Worthington (Monster) r-12 Air Cond systems.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event