Search:

Type: Posts; User: MechAcc

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    5
    Views
    933

    Check out Allied Electronics they have several...

    Check out Allied Electronics they have several sizes.

    http://www.alliedelec.com/search/results.aspx?term=molex+extraction+pin+tool
  2. Thread: Mag Jumpers

    by MechAcc
    Replies
    24
    Views
    2,019

    They can be used on heat pump reversing valves to...

    They can be used on heat pump reversing valves to see if slider is moving.

    http://www.youtube.com/watch?v=j2riZP1nOD0
  3. Cooper MFM 300 uses transducers that connect to...

    Cooper MFM 300 uses transducers that connect to gauge port even less refrigerant wasted than stubby gauges.
  4. Welcome to RSES. I have enjoyed the education and...

    Welcome to RSES. I have enjoyed the education and friends that I have made since joining in 91
  5. The Technical Institute Manuals are 3 Volumes...

    The Technical Institute Manuals are 3 Volumes
    Refrigeration/ Air Conditioning Units have 6 Volumes
    Electricity Units have 5 Volumes
    Electricity for HVAC/R Technicians
    Controls Units have 4...
  6. Gundlach No. 853 The Last Drop Suction Gun

    I found this tool helpful. The hose connection is 3/8 inch which fits most drain traps. You can fill with water and it creates pressure to force water through the trap and agitate debris to flush...
  7. Replies
    11
    Views
    1,265

    Isn't it hydrogen gas

    Isn't it hydrogen gas
  8. Replies
    19
    Views
    2,279

    I have the Yellow Jacket branded version of the...

    I have the Yellow Jacket branded version of the DC 1200 that was mated to the Titan manifold. A Titan manifold should work for the AK900.
  9. Replies
    17
    Views
    2,082

    Try Allied Electronics. They are pretty good at...

    Try Allied Electronics. They are pretty good at shipping same day.
  10. Replies
    16
    Views
    4,544

    From what I have been told the Sporlan tool is...

    From what I have been told the Sporlan tool is for TXV gland nuts.
  11. Replies
    16
    Views
    4,544

    337301 Sporlan Valve Wrench Part Number SPOZ57...

    337301

    Sporlan Valve Wrench Part Number SPOZ57



    337311

    Alco Solenoid Valve Spanner Wrench Part Number X11981-1
    Johnstone Supply B14-082
  12. Thread: vacum setup

    by MechAcc
    Replies
    102
    Views
    13,796

    If you do small systems there is no advantage....

    If you do small systems there is no advantage. However if you do systems that are wet or very large systems then the TEZ 8 is the way to go as you can monitor oil condition and change oil on the go...
  13. Thread: vacum setup

    by MechAcc
    Replies
    102
    Views
    13,796

    You very may well consider adding: Nylog ...

    You very may well consider adding:

    Nylog

    Small bottle of denatured alcohol to clean sensor
  14. Thread: vacum setup

    by MechAcc
    Replies
    102
    Views
    13,796

    Good Job on that kit

    And from the replies you may find that there are things that you may want to add and others that you'll remove.

    Way to XL.
  15. Replies
    39
    Views
    6,189

    The Copeland Scrolls will have a decal stating...

    The Copeland Scrolls will have a decal stating that it has a thermal device.
  16. Replies
    39
    Views
    6,189

    The new scrolls have a thermal relief valve. Once...

    The new scrolls have a thermal relief valve. Once open it does the same thing as a pressure relief allows thermal overload to heat up and shutdown. The overload maybe resetting before the thermal...
  17. Replies
    9
    Views
    1,915

    Itsiceman Remembered taking this photo of...

    Itsiceman

    Remembered taking this photo of Christmas ornament someone gave me. Do think it would make you a good avatar.
  18. Replies
    21
    Views
    3,890

    On Hoshi's monitor the water pressure when it...

    On Hoshi's monitor the water pressure when it goes into harvest. If it drops below 20 psig it may have harvest problems.
  19. Replies
    9
    Views
    1,915

    That is one thing that I didn't like.

    That is one thing that I didn't like.
  20. Replies
    9
    Views
    1,915

    Yellow Jacket uploaded a video of their H2...

    Yellow Jacket uploaded a video of their H2 detector on You Tube

    http://www.youtube.com/watch?v=KDguUryrjPU&feature=plcp
  21. Replies
    21
    Views
    3,890

    If you can get an air wand with a 90 degree tip...

    If you can get an air wand with a 90 degree tip it will be easier.
  22. Replies
    21
    Views
    3,890

    Try Viper Aerosol from Refrigeration...

    Try Viper Aerosol from Refrigeration Technologies. They list list it as safe for all metals. NSF approved for all food process areas. And the best thing there is no pungent odor like other aerosol...
  23. Replies
    44
    Views
    4,589

    Lennox uses the approach method in conjunction...

    Lennox uses the approach method in conjunction with subcooling for charging. Their approach temperatures are below 10 degrees. Check the installation instructions for Lennox AC units.
  24. Replies
    44
    Views
    4,589

    What is the LL approach temperature? Liquid Line...

    What is the LL approach temperature? Liquid Line temperature - Ambient temperature if it is pushing 10 degrees may be a dirty condenser coil. If coil is clean it may be non condensables.
  25. Replies
    44
    Views
    4,589

    Get in the habit of measuring SL and LL...

    Get in the habit of measuring SL and LL temperatures at condensing unit and at evaporator. It will reveal lineset problems.
  26. Our summer class installed a 24.5 SEER iQ Drive...

    Our summer class installed a 24.5 SEER iQ Drive in one of our class rooms. Compressor, condenser fan and air handler motor all modulate to load. We set the controller at 75 degrees and the humidity...
  27. Replies
    102
    Views
    16,014

    Sounds like an innovation for the Binford 5000...

    Sounds like an innovation for the Binford 5000 capacitor add on cooling fins. LOL
  28. Replies
    17
    Views
    2,020

    Years ago I heard from one of my employers that...

    Years ago I heard from one of my employers that someone had called after having a new furnace install that it broke down and the installer would not answer phone calls. Anyway another company came...
  29. Any Trane XV1500's still around?

    Any Trane XV1500's still around?
  30. Replies
    44
    Views
    4,589

    You'll need to locate the condensing unit...

    You'll need to locate the condensing unit information on the required piston size. Have the correct size on hand. Pump the refrigerant back and check to see if the piston is either stuck and not...
  31. Replies
    44
    Views
    4,589

    Measuring the return air at the grille and then...

    Measuring the return air at the grille and then again will show if you are sucking air from another source. IE. your return air at the grille is 73 degrees if the temperature at return air of the...
  32. Replies
    17
    Views
    2,365

    The Dealers Tool Box Video...

    The Dealers Tool Box Video http://www.thedealertoolbox.com/ResidentialHVAC/Training/Videos/CapacitorTraining.aspx
  33. Replies
    17
    Views
    2,365

    Packard capacitor training video...

    Packard capacitor training video http://www.youtube.com/watch?v=TRi5WTntirY
  34. Replies
    6
    Views
    1,654

    Aluminum Tubing Splice Kits

    C&D Valve has updated their web site and one of things that I noticed is that they carry aluminum tubing line splices.

    http://www.cdvalve.com/images/featured_products/line-splice.jpg

    Check them...
  35. Replies
    2
    Views
    690

    Heating and Cooling Supply in Davenport Iowa has...

    Heating and Cooling Supply in Davenport Iowa has a new one on their counter.
  36. Thread: it's not!!!

    by MechAcc
    Replies
    49
    Views
    4,062

    Now how you can you bypass a pressure line with...

    Now how you can you bypass a pressure line with jumper wires? LOL:grin2:
  37. Replies
    55
    Views
    4,314

    YJ finally upgraded their Solars with transducers...

    YJ finally upgraded their Solars with transducers instead of bourdon tubes
  38. Thread: Ball Valves

    by MechAcc
    Replies
    5
    Views
    797

    The Yellow Jacket Quick Seal connectors are not...

    The Yellow Jacket Quick Seal connectors are not recommended by Yellow Jacket for use on R-410a systems. One of my friends had one blow apart on R-410a and says he will never use them again.
  39. Replies
    5
    Views
    706

    Just got the Amprobe ACD51NAV Meter. Clamp on...

    Just got the Amprobe ACD51NAV Meter. Clamp on with AC DC voltage functions, Hz, Peak voltage, amps, watts, power factor, capacitance, microamps, temperature (K type thermocouple), phase rotation, and...
  40. Replies
    201
    Views
    16,821

    The ultrasonic will work better than a...

    The ultrasonic will work better than a stethescope. It amplifys the sound.
  41. Thread: Samsung Hauzen

    by MechAcc
    Replies
    0
    Views
    934

    Samsung Hauzen

    The course got a Samsung Hauzen Kimchi Refrigerator. Off course it does not work. Was told it did not work day one. Displays ERROR on the readout window. Was able to download the Users' Manual but am...
  42. Replies
    31
    Views
    4,148

    Isn't there a 5 year warranty on the zipper?

    Isn't there a 5 year warranty on the zipper?
  43. Replies
    3
    Views
    968

    13 good reviews on it at Amprobe one of the 13...

    13 good reviews on it at Amprobe one of the 13 wished that it was waterproof.

    http://www.amprobe.com/Amprobe/usen/Clamp-Meters/CATIV-Industrial/ACD-51NAV.htm?PID=73092&FocusToReviews=Yes
  44. Thread: GetCool

    by MechAcc
    Replies
    47
    Views
    6,321

    Been two years since last post and with more and...

    Been two years since last post and with more and more states and energy companies requiring more detailed documentation of system installs before awarding rebates it should be time for an update on...
  45. Replies
    28
    Views
    28,387

    Do you have an electronic air cleaner, edenpuire,...

    Do you have an electronic air cleaner, edenpuire, electrostatic air filter? These remove the staining that makes dust dark. Do you have a humidifier? Has it been serviced?
  46. Replies
    5
    Views
    3,139

    Tony Berlin Serice1st /HVAC God passes away

    Tony Berlin of Bloomington , Indiana Service1st passed away from cancer Feb 21.

    He started his own HVAC forum, so I will not mention the name, and a HVAC Blog Site called Digital Zeus.

    Tony...
  47. Thread: DigiCool AK900

    by MechAcc
    Replies
    24
    Views
    2,894

    Because the spring clamps won't fit onto the 2...

    Because the spring clamps won't fit onto the 2 inch diameter suction lines but but the stretchy velcro straps will. Maybe.
  48. Thread: DigiCool AK900

    by MechAcc
    Replies
    24
    Views
    2,894

    Soon If Doug or Eric logs on maybe they can...

    Soon

    If Doug or Eric logs on maybe they can quote a time frame.
  49. Thread: DigiCool AK900

    by MechAcc
    Replies
    24
    Views
    2,894

    The two valve is available now. The four valve...

    The two valve is available now.

    The four valve will be available soon.

    Also soon the new temperature sensors for the AK that have the elastic velcro straps. Forgot to ask if the elastic strap...
  50. Thread: DigiCool AK900

    by MechAcc
    Replies
    24
    Views
    2,894

    DigiCool AK900

    Thank you Doug Lockhardt for your getting hammered in Chicago contest. For those that did not go to the AHR Expo there was a contest of who could bust the case of a DigiCool. I believe the contest...