  1. Replies
    13
    Views
    613

    1 &2 is the start cap contacts on the relay.run...

    1 &2 is the start cap contacts on the relay.run cap was OK. I jumped it for a second or two.
  2. Replies
    13
    Views
    613

    Thank you for that good info.

    Thank you for that good info.
  3. Replies
    13
    Views
    613

    The start cap was dead. I checked it. I replaced...

    The start cap was dead. I checked it. I replaced it with a new one of same specs. I tested it too. Comp started but I shut it off to test it and it didn't start. 1 and 2 had continuity.power again...
  4. Replies
    13
    Views
    613

    Hey thanks for answering. I spoke to Tecumseh...

    Hey thanks for answering. I spoke to Tecumseh tech this am. He said a supper boost will kill the start winding. Also your start cap should always have a bleed resistor for that compressor.
  5. Replies
    13
    Views
    613

    Sorry model aja7465axa

    Sorry model aja7465axa
  6. Replies
    13
    Views
    613

    small walkin box compressor 3/4 hp

    Hey now. Has anyone seen a super boost on a comp.already having a start cap and relay? It was on the run cap. Will this kill the start winding? Thanks all
  7. Replies
    0
    Views
    193

    honeywell w7753A2002 control

    Hi everyone. This control is used a lot in the 5 schools I work in. This is a 5 ton RTU. The cooling relay energizes for 5-7 min. then turns off. The space not cooling to 70 set point. Can I test ...
  8. Replies
    5
    Views
    347

    I should have taken an amp draw.opened lpc.

    I should have taken an amp draw.opened lpc.
  9. Replies
    5
    Views
    347

    compressor not pumping

    Hey now this 40ton aeon has comp. #1 hpc and contactor wire off. The unit is new a year or two old. R410 200 Psi on each gauge comp#1 on brrrr and no press.change . LL same temp.oil in sight glass...
  10. Replies
    13
    Views
    772

    Thank you for this responce.

    Thank you for this responce.
  11. Replies
    13
    Views
    772

    He Mr me plumber I'm posting my new experiences...

    He Mr me plumber I'm posting my new experiences for me and the newbies. I'm 45 yes old with 25 yes exp. When I see a control a finally get my meter on I learn it . What are your qualification? You...
  12. Replies
    3
    Views
    290

    The control on the boiler is a Mc don miller...

    The control on the boiler is a Mc don miller 157s. The schematic is showing a drop in water opens the pump and solenoid. It looks like it will never fill. Also each boiler has a pump. The middle pump...
  13. Replies
    3
    Views
    290

    Shipco condensate pump

    This is a shipco mn. Shem 2 steam boilers. The pump controller on each boiler turns on a pump with drop in level.middle pump of 3 backs up either side with more drop opening a solenoid on Esther side...
  14. Replies
    25
    Views
    1,690

    We had a soft solder joint blow out last...

    We had a soft solder joint blow out last summer.we did 2 systems in the attic. The first knight the customer called and said they heard a loud bang. The liquid line blew on a joint in the middle on...
  15. Replies
    13
    Views
    772

    I have 25 years of up to 400000btu. I took a...

    I have 25 years of up to 400000btu. I took a black seal class many years ago but unfortunately at the end the wouldn't let me take the test because I didn't work for a place with the boiler...
  16. Replies
    25
    Views
    1,690

    I have used the flush kit numerous times for a...

    I have used the flush kit numerous times for a few years.usually a townhouse where line set can't go outside.follow instructions cover eyes
  17. Replies
    9
    Views
    560

    There is an air switch in line with a comp oat...

    There is an air switch in line with a comp oat lockout in hood. With computer forced override small relays pulled in but comp oat and air Sw.are controlling a relay coil to turn on comp contractors. ...
  18. I'm in union cty big roof tops 40 ton 31 ton aeon...

    I'm in union cty big roof tops 40 ton 31 ton aeon metays systems univents airdell
  19. Replies
    9
    Views
    560

    Thank you .used aid tool for geothermal equip...

    Thank you .used aid tool for geothermal equip before the metayas system is new to me. I am new to computer controlled stuff. I'm going to get that this spring.
  20. Replies
    13
    Views
    772

    Sorry that is an ir scanner

    Sorry that is an ir scanner
  21. draining a large hot water system in the summer.

    It is spring time and there are repairs to be made on some large hot water systems but what if not really necessary. One set of pumps 15hp. The other two 7 HP. I'm new to over 400000 btu...
  22. Replies
    13
    Views
    772

    I spoke to fireye tech.this is an is scanner. It...

    I spoke to fireye tech.this is an is scanner. It displays on the screen 0-80. I was confused that I needed to check the s s terminals with my meter. Not with this ir scanner. It is reading 10 and the...
  23. Replies
    13
    Views
    772

    power flame burner

    The model is cr3-co-25 an 089050995 what proves the pilot flame? I read a fireye booklet in the boiler room. I saw terminals to check flame.how do I verify pilot and main flame signal.?I'm glad the...
  24. Replies
    9
    Views
    560

    aaeon 40 ton rtu

    The unit is controlled w metays system. I over rode 4 stages of compressors. Never came on. Lowered oat lock out to 45. Erv wheels on exhaust wheel on no comp. Fuses good . Raining so boards getting...
  25. I'm now in charge of 2 approx.2 million btu...

    I'm now in charge of 2 approx.2 million btu boilers in a high school . The boiler psi is 27. New feeder.25-75 psi 1 in. Set for 27 psi water 170 deg. The tops are teed together to 4 huge expansion...
Results 1 to 25 of 248