  1. Replies
    17
    Views
    1,894

    The orig call was no heat and had a bad blower...

    The orig call was no heat and had a bad blower motor replaced the motor and the board died replaced both and furnace ran great for several cycles and left. 24 hrs later tripped on roll out, reset and...
  2. Replies
    17
    Views
    1,894

    good point maybe when the HX gets hot it open up.

    good point maybe when the HX gets hot it open up.
  3. Replies
    17
    Views
    1,894

    Replaced the blower motor on start up the board...

    Replaced the blower motor on start up the board died.
  4. Replies
    17
    Views
    1,894

    Amana roll out switch

    Hi All,
    I replaced a blower motor and a WR control board on a Amana GUCA 13 year old furnace worked 1 day then no heat fan run all the time. Tripped out on roll out reset and furnace runs great for...
  5. Replies
    3
    Views
    465

    Its natural gas and I don't thing it was ever...

    Its natural gas and I don't thing it was ever service. The burner were rusty
  6. Replies
    3
    Views
    465

    burners not lighting

    Hi All,
    Went on a service call last week, complant was the indoor temp was 2 -3 deg below tstat setting. It was a Ducane furnace appox 7 years old and observed one burner lighting and the flame...
  7. Lennox G71 Furnace problems with stand by geneators

    I installed a gardian generator 10KW three years ago, my costomer forgot i sold furnaces a local competitor installed a G71 in Dec. They had a power outage last week everything worked but the...
  8. Replies
    17
    Views
    1,954

    Maybe the blower wheel lost a balance weight and...

    Maybe the blower wheel lost a balance weight and the wheel is shot?
  9. Replies
    11
    Views
    1,523

    Get a price on the best v speed furnace out there...

    Get a price on the best v speed furnace out there with the infinity tstat by Carrier. Also go with R410a (Puron) not subject to phase out. The price of R22 is going way up. Put a good air filter on...
  10. Thread: psc vs. ecm

    by dex1
    Replies
    18
    Views
    7,724

    I did a op cost last year for a varible speed...

    I did a op cost last year for a varible speed furnace runing the fan 24/7 ecm was 5$ vs 55$ a month for a psc. Im sure based on a well designed duct system. Also to help sell the units with ecm...
  11. Replies
    7
    Views
    1,281

    The extrol tank is dry no indications of it being...

    The extrol tank is dry no indications of it being water logged, no air in the baseboard. The pd was 20. Maybe the fill valve. How can you check if its not seating a 100% ?

    Thanks
  12. Thread: Ducane vs Goodman

    by dex1
    Replies
    9
    Views
    5,942

    Is price the only thing your looking for?? Why...

    Is price the only thing your looking for?? Why not look for a Carrier,Trane or Lennox Dealer.
  13. Replies
    7
    Views
    1,281

    boiler relief valve bad??

    I have a Dunkirk water boiler around 75k and appox 12 years old. When the burners come on it sounds like its on a heart lung machine, every 5-7 seconds you here a pressure sound until burners goes...
  14. Replies
    16
    Views
    1,216

    Did you check gas pressure with all appliances...

    Did you check gas pressure with all appliances on? Also I think you should be between 4.5-13 in wc supply pressure ng. Thats what the gfa,dfa,pap,rap are.

    dex1
  15. Replies
    7
    Views
    786

    Hay Alex, The credit is based on 95% AFUE dex1

    Hay Alex, The credit is based on 95% AFUE

    dex1
  16. Replies
    30
    Views
    2,740

    Thanks Chillbilly, I couldn't say it any...

    Thanks Chillbilly,

    I couldn't say it any better. Maybe we shouldn't talk these units up so much, we need competitors.

    Dex1
  17. Replies
    30
    Views
    2,740

    Payne is there for Carrier and Bryant dealer to...

    Payne is there for Carrier and Bryant dealer to compete in the Goodman price range. Not only are they constructed better they are quieter. The pitcher shown is the Carrier base (builder) model. Go...
  18. Replies
    30
    Views
    2,740

    Payne is Carriers way to get into the price arena...

    Payne is Carriers way to get into the price arena with Goodman, but is far better constuction than Goodman. It has the same parts as a carrier except main board and 20 year on HX vs Life time. Get a...
  19. The builder should have known what was needed, he...

    The builder should have known what was needed, he is responsable to get it right. Budget 550 sq ft/ ton to get a rough idea of load. Now if 5 tons is correct add a 4 zone Carrier infinity system with...
  20. Replies
    27
    Views
    1,944

    Time to replace, like rebuilding a car with 150k...

    Time to replace, like rebuilding a car with 150k miles. Check out the Carrier infinity series furnaces. with the air purifier
  21. Replies
    21
    Views
    1,419

    Don't do it, many call backs ahead. He probably...

    Don't do it, many call backs ahead. He probably thinks your a hero for getting the condemned unit going, put a new smaller fan coil in. Remember if the fan coil is older than 1992 its considered 8...
  22. Replies
    10
    Views
    3,268

    58sxa night time lockout

    Hi all,

    Thanks for your inputs. I talked the other night to our area Carrier service manager who was around in the time frame of 58sx,sxas. When Carrier upgraded to a new electronic igniter they...
  23. Replies
    10
    Views
    3,268

    58sxa gas furnace lock out

    I was called out on a 15 year old 58sxa nat gas condensing furnace last week,the problem lockout in the night two to 3 times a week, costomer will turn power off on than back on in the morning funace...
Results 1 to 23 of 23