Search:

Type: Posts; User: kdean1

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Sorry, no DIY at this site. Please read the rules.

    Sorry, no DIY at this site. Please read the rules.
  2. Replies
    20
    Views
    621

    You can't go wrong with that!

    You can't go wrong with that!
  3. Replies
    4
    Views
    348

    RUN AWAY from home warranty companies and their...

    RUN AWAY from home warranty companies and their contractors. Their work is terrible, even dangerous, judging from what I have seen.

    Search online for complaints about home warranty companies.
  4. Replies
    1
    Views
    216

    Becoming a Diamond dealer for Mitsubishi involves...

    Becoming a Diamond dealer for Mitsubishi involves a 3 day training class covering equipment selection, installation and service. I considered it a good class. Installations by Diamond dealers extends...
  5. Replies
    14
    Views
    1,209

    Hang the cost overrun! You're killing the furnace...

    Hang the cost overrun! You're killing the furnace with undersized ducts and restrictive air filters.
    Replacing the duct system is likely to be the only way to have even a new, properly sized...
  6. Replies
    31
    Views
    1,284

    Ask him what "adequate" means. From ADC...

    Ask him what "adequate" means.

    From ADC Flexible Duct Performance & Installation Standards, 5th Edition
    "4.4 Installation and Usage
    Install ducts fully extended. Do not install in the...
  7. Replies
    6
    Views
    218

    I'm not familiar with all brands of thermostats....

    I'm not familiar with all brands of thermostats. Most equipment manufacturers have their thermostats made by others. The only time a manufacturer's thermostat is needed is for communicating equipment...
  8. And your OCD. :angel:

    And your OCD. :angel:
  9. Replies
    6
    Views
    218

    The Prestige IAQ is very user friendly and has...

    The Prestige IAQ is very user friendly and has the features you need.
  10. Replies
    10
    Views
    296

    Hey everybody! Remember the NO DIY rule?

    Hey everybody! Remember the NO DIY rule?
  11. 3 1/2 months with no resolution or even any...

    3 1/2 months with no resolution or even any action? Kick him to the curb! Demand a full refund for breach of contract. Tell him you're considering legal action.
  12. Replies
    4
    Views
    226

    I don't know of a similar thermostat. However I...

    I don't know of a similar thermostat. However I question the application of the furnace - what size is it that it runs such a short cycle? A properly sized furnace should run long enough to eliminate...
  13. Replies
    31
    Views
    1,284

    Two quick comments - Flex should never be...

    Two quick comments -
    Flex should never be constricted. He should have attached a metal 90* to the damper before putting it in the ceiling. Instead of using round registers they could have used a 90*...
  14. Replies
    31
    Views
    1,284

    See posts #4 & 13. There's a forced air split...

    See posts #4 & 13. There's a forced air split system in the house, too.
  15. That is what I suspect. Run the dehumidifier for...

    That is what I suspect. Run the dehumidifier for a while longer as it certainly can't hurt.
  16. Replies
    31
    Views
    1,284

    I think the 5/8" or 3/4" issue has to do with a...

    I think the 5/8" or 3/4" issue has to do with a standard split system instead of a ductless.
  17. The ductless systems that I know of use inverter...

    The ductless systems that I know of use inverter technology which will reduce the capacity to match the load as it runs. That eliminates oversizing unless the unit is set too a very low cooling...
  18. Replies
    31
    Views
    1,284

    Yuck! What a mess! The lineset for the ductless...

    Yuck! What a mess! The lineset for the ductless system should have been cut and flared to eliminate the excess. There is a minimum length as well as a maximum length. Unless it is more than 50' (not...
  19. Replies
    6
    Views
    288

    We put two Mitsubishi systems in a house last...

    We put two Mitsubishi systems in a house last year. We installed a High Heat unit in the living room for the downstairs and a multi-zone for 3 rooms upstairs. The customer is thrilled with it.

    I...
  20. Replies
    17
    Views
    445

    To what extent are you changing the ducts? The...

    To what extent are you changing the ducts? The whole system or just some upgrades?

    There is no reason to use bigger equipment if the existing 3 ton system handled the load.

    Why do you WANT a...
  21. Replies
    22
    Views
    560

    Furnace model # and board # would be helpful. My...

    Furnace model # and board # would be helpful. My mind is still in air conditioning mode.
  22. Replies
    22
    Views
    560

    You may have misunderstood the purpose of this...

    You may have misunderstood the purpose of this site. It is a forum for HVAC professionals to discuss technical and business matters. It is not for DIY (Do It Yourself) repairs.
    We cannot give...
  23. Gravity is not the force which moves air. It is...

    Gravity is not the force which moves air. It is pressure differential, usually accomplished by a blower designed for the application. An 8" duct booster will not generate enough pressure to move...
  24. What size sticks do you use? :grin2:

    What size sticks do you use? :grin2:
  25. Replies
    53
    Views
    1,703

    Here's how your apology should go - "Coolshower,...

    Here's how your apology should go -
    "Coolshower, I'm sorry I attacked you. I misread your post. Please accept my apology."