    Application Engineering Training

    I was ask the same question recently and while searching the web I only found short courses on several subjects but nothing like I had at Bloomington,MN with Honeywell back in '81. It was 5 weeks 40...
  2. Replies
    11
    Views
    1,105

    Re: R-2 Help

    Do you have Workbench for R-2's? Give me an idea of what you have. I might be able to help you. My email is in my profile,,,,,,,,,,,,,,rrh
  3. Replies
    5
    Views
    857

    I spent 5 weeks in HW engineering school in...

    I spent 5 weeks in HW engineering school in Minnisota to understand the different types of HVAC systems and how to control them. The school of hard knoxs takes longer. I don't know of a flow chart...
  4. Replies
    5
    Views
    857

    Welcome to the forum!

    I see you are new to this forum. I am sure there will be others that will differ from my opinon and that's all it is, my opinion. I worked for Honeywell for nearly 18 years, with the Commercial...
  5. Replies
    3
    Views
    470

    Depend

    I worked for Honeywell for almost 18 yrs, worked for a sister service company to a major mech contractor before retiring. The service company was forbidden to bid control projects that would put the...
  6. Replies
    16
    Views
    1,043

    Control_Man is Right!

    The wheel works great, your company will be best served by searching out a reputable controls contractor. My suggestion, unless you are very good at mechanical/controls, is to find an HVAC controls...
  7. Replies
    3
    Views
    395

    Just Asking,,,,,,,

    I suppose your laptop is in the same IP group and submask? Also are you using a crossover cable for direct connect? Those lites can be mis-leading.

    Do you have a serial cable made up to...
  8. Off My Rocker?

    I won't be so critical to judge another product. I have installed both Honeywell and JCI AX's and I would say the support you get from your distributors would be my choice of brand. Since Honeywell...
  9. Replies
    21
    Views
    4,132

    To me it's a front end

    I recall the first demo I saw several years ago. It was an R-2 version. I couldn't wait to get my hands on one and try my hand doing what I have done for the past 25 years with old DOS based...
  10. FX-60 for me

    I agree with Reaper, there is not enough money difference in the 20 and the 60 price to cut corners. The 20 will do your job but not much spare room.
  11. Replies
    6
    Views
    702

    Just Curious,

    I would guess that you didn't install the resourse file associated with each model TEC. Have you tried this?
    ...
  12. Your location would make a lot of difference!

    The dual duct systems I have been involved with here in Texas, we use reset on both hot and cold decks from OA Temp.
  13. Replies
    15
    Views
    1,130

    If I was mounting a 40X32X7 NEMA 3R or NEMA 12...

    If I was mounting a 40X32X7 NEMA 3R or NEMA 12 panel, I would get some help. I wouldn't attempt mounting a heavy panel without using Unistrut. Place blocks or support under the panel until it is...
  14. Replies
    15
    Views
    1,130

    And on Unistrut

    And on Unistrut
  15. Replies
    15
    Views
    1,130

    I didn't know there was a rule book!!

    Our branch always placed the top of the cabinet at 6' AFF, unless the owner asked for a different height.
  16. Replies
    4
    Views
    705

    Check out Belimo, they have linkage and actuators...

    Check out Belimo, they have linkage and actuators made for all series of Siebe,Invensys,B-C. Most distributors have then in stock.


    https://www.belimo.us/belimoshop/index.jsp?shopId=BELIMO
  17. Replies
    12
    Views
    1,927

    TAC Who?

    Back in the day, you were wasting your time calling TAC. But get to know your Honeywell Rep. Richard has bailed me out several times. I never have to wait over 3 hours for an answer. The last...
  18. Gosh I love construction!@!!

    Cook you didn't say if this job is a plan/spec job or a remodel. If it is plan/spec job, look in division 15 and see if the electgrical work for division 15 states it will; be done by division 16. ...
  19. Sorry about your 10 year old system!

    You mentioned in your post, "Open Source" and guess what, you just opened up a big can of worms that will go on and on for days around here. You requested ideas that you could mention at your...
  20. I like my pension check too!!!

    Almost 18 years, probably some of the best years of my life. You young wipper-snappers keep up the good work.
  21. Not necessarly a Honeywell tract, control...

    Not necessarly a Honeywell tract, control companies have to meet the specification of the mechcanical engineer who dictate ahat will be normally open or closed. And don't forget that they make...
  22. Replies
    3
    Views
    581

    Good Luck Measuring Nat Gas!

    I have done gas measurement using orfice plates and Smart DP sensors. On another job we used electronic sensors and I beleive the brand was Electro which worked along the same principal with a known...
  23. Replies
    17
    Views
    1,375

    When I worked for Honeywell CCD, commercial...

    When I worked for Honeywell CCD, commercial construction division, we often were called in to assist with PC estimates. At the time, all PC's were done by the service group. As the price of...
  24. Replies
    247
    Views
    14,224

    Bacnet - Lon or something else

    Now we know why you are down on Lon!
  25. Replies
    247
    Views
    14,224

    How about front end?,,,,,,,,,rrh

    How about front end?,,,,,,,,,rrh
  26. Replies
    247
    Views
    14,224

    Amen!!!

    My guess is the OP is new to the control business and hasn't worked with properiety systems like the Honeywell D1000, JCI JC-80, the old Parker stuff. I was spoiled to Tridium several years ago...
  27. Replies
    7
    Views
    830

    If you have doubt about your T-921 sensor, pull...

    If you have doubt about your T-921 sensor, pull the cover off of the sensor, adjust the setpoint until the wiper arm is approx at center span. Then measure the resistance between the W and R, then B...
  28. Replies
    7
    Views
    830

    Valve V5013?

    A V5013 is a 3 way valve where V5011 is a 2 way valve. I have seen the "B" port plugged to make a 2 way operation in which case it would be considered a reverse operation. In any case the reversing...
  29. Replies
    7
    Views
    830

    With a 3-way valve like the V5013 with a series...

    With a 3-way valve like the V5013 with a series 90 sensor and valve actuator, it is not un-common to have the tstat "B" connected to the actuator "W" and tstat "W" connected to actuator "B". It all...
  30. Replies
    12
    Views
    841

    Thanks,,

    Yes to the quicklit question, the name didn't register. That's where I found the 24-9890-455 literature at. Not much info there except that the EC is 0-10 DC output. I'll send my request to the...
  31. Replies
    12
    Views
    841

    What is quicklit? I have 24-9890-455, Rev C...

    What is quicklit? I have 24-9890-455, Rev C literature. Supervisory device is FX40. I found the mixed air sensor as ADI-11.......................rrh
  32. Replies
    12
    Views
    841

    TEC-2104-3

    I figured since this is a vendor item they (Viconics) would not use an AO like JCI equipment. I don't need it to be writeable either. I have tried numerous ADI #'s with no success but I thought...
  33. Replies
    12
    Views
    841

    ABCS Guys I need your help!!

    I recently install several JCI TEC-2104-3 multistage 2H2C with economizer controllers. They work great and they are really an expensive device. My problem is, does anyone know what the ADI or AO...
  34. Replies
    17
    Views
    2,394

    Signal was developed by a company in...

    Signal was developed by a company in Albuquerque,NM Data ????? something. It was bought up during the Siebe era and I believe that there was an XP version offered by Invensys before it was bought by...
  35. Replies
    5
    Views
    937

    From a retired Honeyweller!

    I spent almost 18 years with HW and probably should have spent more after looking back. I tell my kids to try to work for a company with a pension and stay with them until they are vested. I sure...
  36. Replies
    6
    Views
    897

    Another Honeyweller

    Well here's another one , I put in 17.5 years as a tech in Texas. I thank Honeywell ever month for the pneumatic,DDC, NICET training and fire & security training I received over the years. My...
  37. Replies
    3
    Views
    474

    Just My Opinion

    My opinion is that the R-2 has nothing to do with your problem. If this old man was there, I would isolate 1 XL-10 hooked to my laptop with Lonspec. Tee into the flow ring with a 1" Magnihelic. A...
  38. Replies
    5
    Views
    1,768

    What supervisory controller?

    I have an idea that could have caused the override and it's only an idea. This system is an FX-40 running 1.0, my first station AX to install. I have R2 experience but not with JCI equipment. In...
  39. Replies
    5
    Views
    1,768

    Override problem

    I had a simular problem just recently. I was about ready to download the controller again but opened up commissioning first. Several points were in override, which I had not done. Whenever exiting...
  40. Replies
    51
    Views
    3,929

    FX has my vote too!

    The OP made the deciding statement for my vote. If my company had canceled a contract because of ill fealings I wouldn't be considering a major purchase from that company. I wouldn't be going down...
  41. Replies
    3
    Views
    716

    Honeywell Boiler Reset

    That number don't ring a bell with me but that's nothing new. If it was me, I would visit my local Honeywell office and ask if they will furnish you a copy of the literature. When I worked at HW we...
  42. Replies
    8
    Views
    915

    Ports Open

    If you are behind a firewall, yes you will need more ports opened, 1911 for FOX and 3011 for platform, mainly for Workbench. An IT dude may know otherwise what you need for the weather service, but I...
  43. Replies
    8
    Views
    915

    AX Weather

    Over the past few months I too have toyed with the weather feature. At times it would work, only to come back at a later date to see that the auto update had stalled (stale). Reading the...