  1. Trane Intellipak VOM Communications Failure

    I'm getting a Ventilation Override Module Com Failure on one of my Intellipaks. Can't seem to find any problems with the communications cable to the VCM that tech support believes the problem lies....
  2. Replies
    6
    Views
    1,688

    Recall

    Thanks Guys! And thanks for the Service Bulletin. I called Trane and they confirmed the problem. The recall HAS expired as of 12/31/2009 so it's costing $492.50 for the combustion assembly, $84.00...
  3. Replies
    6
    Views
    1,688

    Trane Voyager Combustion Fan Recall?

    Hi, Has anyone heard of a recall for the combustion fan motor on the Voyager series? I have a YCD240B4LAJB that I replaced the ignition module on that burned up. I still have a diagnostic 1/4 second...
  4. Replies
    2
    Views
    744

    AquaSnap 30RB060-210 Transducer

    Hi All, Have an issue with a transducer on a 30RB. Came up as an alert on the display and is showing -36psi. I'm figuring the transducer failed and needs to be replaced. My question is.....Is it...
  5. Replies
    2
    Views
    504

    Thank You! Changed the accel and decel times to...

    Thank You! Changed the accel and decel times to 60 secs.. Seems to have corrected my problem..
  6. Replies
    13
    Views
    1,142

    Controllers in cabinet

    I have 8 40T Intellipaks with 2 UNT's installed in each for JCI Metasys. No comm problems whatsoever being mounted in same cabinet. Could be a safety issue like you mention though, with the 480V...
  7. Replies
    2
    Views
    504

    Siemens "busy" display on VFD

    Hi all, Getting a "busy" display on a Seimens sed2 VFD. Had a utility bump but doesn't look like it lost any parameters. Fan runs in by-pass with no problems. All safeties are closed. O&M manual says...
  8. Replies
    10
    Views
    1,926

    Great......I'm having 2 30RB210's installed in my...

    Great......I'm having 2 30RB210's installed in my campus as we type....
  9. Replies
    15
    Views
    3,169

    Some added input here is that the head should be...

    Some added input here is that the head should be at 240# while bringing the float to 1/2 sightglass. Ran across this problem while charging one while it was near 0 F on a rooftop. Leibert tech...